Landscape Position Project at North Temperate Lakes LTER: Chemical Limnology 1998 - 2000
Abstract
Parameters characterizing the chemical limnology and spatial attributes of 51 lakes were surveyed as part of the Landscape Position Project. Parameters are measured at or close to the deepest part of the lake. The following parameters are measured one meter from the surface and two meters from the bottom of the lake: pH, total phosphorus, total nitrogen, total silica. The following parameters are measured one meter from the surface: dissolved organic carbon, total organic carbon, dissolved inorganic carbon, total inorganic carbon, spectrophotometric absorbance (color scan), major anions and cations, alkalinity. Sampling Frequency: once for conservative parameters (major ions, carbon, color, alkalinity); monthly for one summer for other parameters (chlorophyll, nitrogen, phosphorus, pH, silica, temperature, dissolved oxygen, and conductivity) Number of sites: 51Allequash Lake, Anderson Lake, Arrowhead Lake, Beaver Lake, Big Lake, Big Crooked Lake, Big Gibson Lake, Big Muskellunge Lake, Boulder Lake, Brandy Lake, Crampton Lake, Crystal Lake, Diamond Lake, Flora Lake, Heart Lake, Ike Walton Lake, Island Lake, Johnson Lake, Katherine Lake, Kathleen Lake, Katinka Lake, Lehto Lake, Little Crooked Lake, Little Muskie, Little Spider Lake, Little Sugarbush Lake, Little Trout Lake, Lower Kaubeshine Lake, Lynx Lake, McCullough Lake, Mid Lake, Minocqua Lake, Muskesin Lake, Nixon Lake, Partridge Lake, Randall Lake, Round Lake, Sanford Lake, Sparkling Lake, Statenaker Lake, Stearns Lake, Tomahawk Lake, Trout Lake, Upper Kaubeshine Lake, Verna Lake, Ward Lake, White Birch Lake, White Sand Lake, Wild Rice Lake, Wildcat Lake, Wolf Lake, Vilas County, WI, Iron County, WI, Oneida County, WI, Gogebic County, MI, USA
Contact
Core Areas
Dataset ID
91
Data Sources
Date Range
-
Maintenance
completed
Metadata Provider
Methods
Chloride, SulfateSamples for chloride and sulfate are collected together with a peristaltic pump and tubing and in-line filtered (through a 0.40 micron polycarbonate filter) into new, 20 ml HDPE plastic containers with conical caps. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 6 months. The samples are analyzed for chloride (and sulfate) simultaneously by Ion Chromatography, using a hydroxide eluent.The detection limit for chloride is approximately 0.01 ppm and the analytical range for the method extends to 100 ppm.The detection limit for sulfate is approximately 0.01 ppm and the analytical range for the method extends to 60 ppm.Method Log: Prior to January 1998 samples, chloride was determined on a Dionex DX10 Ion Chromatograph, using a chemical fiber suppressor. From 1998 to 2011, chloride was determined by a Dionex model DX500, using an electro-chemical suppressor. From January 2011 until present, chloride is determined by a Dionex model ICS 2100 using an electro-chemical suppressor.Calcium, silicon, magnesium, sodium, potassium, iron, and manganeseSamples for calcium analysis (as well as dissolved nitrogen and phosphorus, silicon, magnesium, sodium, potassium, iron, and manganese) are collected together with a peristaltic pump and tubing and in-line filtered (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 ml of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius.Calcium, as well as magnesium, sodium, potassium, iron, and manganese are analyzed simultaneously on an optical inductively-coupled plasma emission spectrophotometer (ICP-OES). The acidified samples are directly aspirated into the instrument without a digestion. Calcium is analyzed at 317.933 nm and at 315.887 nm and viewed axially for low-level analysis and radially for high level analysis.The detection limit for calcium is 0.06 ppm with an analytical range of the method extends to 50 ppm.The detection limit for iron is 0.02 ppm with an analytical range of the method extends to 20 ppm.The detection limit for magnesium is 0.03 ppm with an analytical range of the method extends to 50 ppm.The detection limit for manganese is 0.01 ppm with an analytical range of the method extends to 2 ppm.The detection limit for potassium is 0.06 ppm with an analytical range of the method extends to 10 ppm.The detection limit for sodium is 0.06 ppm with an analytical range of the method extends to 50 ppm.Method Log: Prior to January 2002, Calcium, magnesium, sodium, potassium, iron, and manganese were determined on a Perkin-Elmer model 503 Atomic Absorption Spectrophotometer. Lanthanum at a 0.8percent concentration was added as a matrix modifier to suppress chemical interferences. From January 2002 to present, samples are analyzed for calcium on a Perkin-Elmer model 4300 DV ICP.Dissolved reactive silica is determined by the Heteropoly Blue Method and the absorption is measured at 820 nm.The detection limit for silicon is 6 ppb and the analytical range is 15000 ppb.Method Log These determinations were performed manually using a Bausch and Lomb Spectrophotometer from the beginning of the project until April 1984. From 1984 through 2005, dissolved reactive silicon was determined on a Technicon Auto Analyzer II. From January 2006 to present, samples are run on an Astoria-Pacific Astoria II Autoanalyzer.
NTL Keyword
Short Name
LPPCHEM1
Version Number
9