US Long-Term Ecological Research Network

LTREB Biological Limnology at Lake Myvatn 2012-current

Abstract
These data are part of a long-term monitoring program in the central part of Myvatn that represents the dominant habitat, with benthos consisting of diatomaceous ooze. The program was designed to characterize import benthis and pelagic variables across years as midge populations varied in abundance. Starting in 2012 samples were taken at roughly weekly inervals during June, July, and August, which corresponds to the summer generation of the dominant midge,<em>Tanytarsus gracilentus</em>.
Creator
Dataset ID
296
Date Range
-
Maintenance
Ongoing
Metadata Provider
Methods
Benthic Chlorophyll Field sampling (5 samples) (2012, 2013)1. Take 5 cores from the lake2. Cut the first 0.75 cm (1 chip) of the core with the extruder and place in deli container. Label with date and core number.3. Place deli containers into opaque container (cooler) and return to lab. This is the same sample that is used for the organic matter analysis.In 2014, the method for sampling benthic chlorophyll changed. The calculation of chlorophyll was changed to reflect the different area sampled. Below is the pertinent section from the methods protocols. Processing after the collection of the sample was not changed.Take sediment samples from the 5 cores collected for sediment characteristics. Take 4 syringes of sediment with 10mL syringe (15.96mm diameter). Take 4-5cm of sediment. Then, remove bottom 2cm and place top 2cm in the film canister.Filtering1. Measure volume of material in deli container with 60mL syringe and record.2. Homogenize and take 1mL sample with micropipette. The tip on the micropipette should be cut to avoid clogging with diatoms. Place the 1mL sample in a labeled film canister. Freeze sample at negative 20 degrees Celsius unless starting methanol extraction immediately.3. Add 20mL methanol. This methanol can be kept cool in the fridge, although then you will need a second bottle of methanol for the fluorometer. Shake for 5 sec.4. After 6-18 hours, shake container for 5 sec.Fluorometer1. Allow the film canisters to sit at room temperature for approximately 15 min to avoid excessive condensation on the glass tubes. Shake tubes for 5 sec after removing from fridge but then be careful to let them settle before removing sample.2. Record the sample information for all of the film canisters on the data sheet.3. Add 4mL of sample to a 13x100mL glass tube.4. Insert the sample into the fluorometer and record the reading in the Fluor Before Acid column. The sample reading should be close to one of the secondary solid standards (42ug/L or 230ug/L), if not, dilute the sample to within 25 per cent of the secondary solid standards (30-54ug/L or 180-280ug/L). It is a good idea to quickly check 2mL of a sample that is suspected to be too high to get an idea if other samples may need to be diluted. If possible, read the samples undiluted.5. If a sample needs to be diluted, use a 1000 microLiter pipette and add 2mL of methanol to a tube followed by 2mL of undiluted sample. Gently invert the tube twice and clean the bottom with a paper towel before inserting it into the fluorometer. If the sample is still outside of the ranges above, combine 1 mL of undiluted sample with 3 mL of methanol. Be sure to record the dilution information on the data sheet.6. Acidify the sample by adding 120microLiters of 0.1 N HCl (30microLiters for every one mL of sample). Then gently invert the sample and wait 90 seconds (we used 60 seconds in 2012, the protocol said 90) before putting the sample into the fluorometer and recording the reading in the Fluor After Acid column. Be sure to have acid in each tube for exactly the same amount of time. This means doing one tube at a time or spacing them 30-60 seconds apart.7. Double check the results and redo samples, which have suspicious numbers. Make sure that the after-acidification values make sense when compared to the before acidification value (the before acid/after acid ratio should be approximately the same for all samples).Clean up1. Methanol can be disposed of down the drain as long as at least 50 times as much water is flushed.2. Rinse the film canisters and lids well with tap water and scrub them out with a bottle brush making sure to remove any remaining filter paper. Give a final rinse with distilled water. Pelagic Chlorophyll Field sampling (5 samples)1. Take 2 samples at each of three depths, 1, 2, and 3m with Arni&rsquo;s zooplankton trap. For the 1m sample, drop the trap to the top of the chain. Each trap contains about 2.5L of water when full. 2. Empty into bucket by opening the bottom flap with your hand.3. Take bucket to lab.Filtering1. Filter 1L water from integrated water sample (or until the filter is clogged) through the 47 mm GF/F filter. The pressure used during filtering should be low ( less than 5 mm Hg) to prevent cell breakage. Filtering and handling of filters should be performed under dimmed lighting.2. Remove the filter with forceps, fold it in half (pigment side in), and put it in the film canister. Take care to not touch the pigments with the forceps.3. Add 20mL methanol. This methanol can be kept cool in the fridge, although then you will need a second bottle of methanol for the fluorometer. Shake for 5 sec. and place in fridge.4. After 6-18 hours, shake container for 5 sec.5. Analyze sample in fluorometer after 24 hours.Fluorometer1. Allow the film canisters to sit at room temperature for approximately 15 min to avoid excessive condensation on the glass tubes. Shake tubes for 5 sec after removing from fridge but then be careful to let them settle before removing sample.2. Record the sample information for all of the film canisters on the data sheet.3. Add 4mL of sample to a 13x100mL glass tube.4. Insert the sample into the fluorometer and record the reading in the Fluor Before Acid column. The sample reading should be close to one of the secondary solid standards (42ug/L or 230ug/L), if not, dilute the sample to within 25 percent of the secondary solid standards (30-54ug/L or 180-280ug/L). It is a good idea to quickly check 2mL of a sample that is suspected to be too high to get an idea if other samples may need to be diluted. If possible, read the samples undiluted.5. If a sample needs to be diluted, use a 1000uL pipette and add 2mL of methanol to a tube followed by 2mL of undiluted sample. Gently invert the tube twice and clean the bottom with a paper towel before inserting it into the fluorometer. If the sample is still outside of the ranges above, combine 1 mL of undiluted sample with 3 mL of methanol. Be sure to record the dilution information on the data sheet.6. Acidify the sample by adding 120 microLiters of 0.1 N HCl (30 microLiters for every one mL of sample). Then gently invert the sample and wait 90 seconds (we used 60 seconds in 2012, the protocol said 90) before putting the sample into the fluorometer and recording the reading in the Fluor After Acid column. Be sure to have acid in each tube for exactly the same amount of time. This means doing one tube at a time or spacing them 30-60 seconds apart.7. Double check the results and redo samples, which have suspicious numbers. Make sure that the after-acidification values make sense when compared to the before acidification value (the before acid/after acid ratio should be approximately the same for all samples).Clean up1. Methanol can be disposed of down the drain as long as at least 50 times as much water is flushed.2. Rinse the film canisters and lids well with tap water and scrub them out with a bottle brush making sure to remove any remaining filter paper. Give a final rinse with distilled water. Pelagic Zooplankton Counts Field samplingUse Arni&rsquo;s zooplankton trap (modified Schindler) to take 2 samples at each of 1, 2, and 3m (6 total). For the 1m sample, drop the trap to the top of the chain. Each trap contains about 2.5L of water when full. Integrate samples in bucket and bring back to lab for further processing.Sample preparation in lab1. Sieve integrated plankton tows through 63&micro;m mesh and record volume of full sample2. Collect in Nalgene bottles and make total volume to 50mL3. Add 8 drops of lugol to fix zooplankton.4. Label bottle with sample date, benthic or pelagic zooplankton, and total volume sieved. Samples can be stored in the fridge until time of countingCounting1. Remove sample from fridge2. Sieve sample with 63 micro meter mesh over lab sink to remove Lugol&rsquo;s solution (which vaporizes under light)3. Suspend sample in water in sieve and flush from the back with squirt bottle into counting tray4. Homogenize sample with forceps or plastic pipette with tip cut off5. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted as well.6. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridgeSubsamplingIf homogenized original sample contains more than 500 individuals in the first line of counting tray, you may subsample under the following procedure.1. Return original sample to Nalgene bottle and add water to 50mL2. Homogenize sample by swirling Nalgene bottle3. Collect 10mL of zooplankton sample with Hensen-Stempel pipette4. Empty contents of Hensen-Stempel pipette into large Bogorov tray5. Homogenize sample in tray with forceps or plastic pipette with tip cut off6. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too! 7. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridge Benthic Microcrustacean Counts Field samplingLeave benthic zooplankton sampler for 24h. Benthic sampler consists of 10 inverted jars with funnel traps in metal grid with 4 feet. Set up on bench using feet (on side) to get a uniform height of the collection jars (lip of jar = 5cm above frame). Upon collection, pull sampler STRAIGHT up, remove jars, homogenize in bucket and bring back to lab. Move the boat slightly to avoid placing sampler directly over cored sediment.Sample preparation in lab1. Sieve integrated samples through 63 micrometer mesh and record volume of full sample2. Collect in Nalgene bottles and make total volume to 50mL3. Add 8 drops of lugol to fix zooplankton.4. Label bottle with sample date, benthic or pelagic zooplankton, and total volume sieved. Samples can be stored in the fridge until time of countingCounting1. Remove sample from fridge2. Sieve sample with 63 micrometer mesh over lab sink to remove Lugol&rsquo;s solution (which vaporizes under light)3. Suspend sample in water in sieve and flush from the back with squirt bottle into counting tray4. Homogenize sample with forceps or plastic pipette with tip cut off5. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too!6. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridgeSubsamplingIf homogenized original sample contains more than 500 individuals in the first line of counting tray, you may subsample under the following procedure.1. Return original sample to Nalgene bottle and add water to 50mL2. Homogenize sample by swirling Nalgene bottle3. Collect 10mL of zooplankton sample with Hensen-Stempel pipette4. Empty contents of Hensen-Stempel pipette into large Bogorov tray5. Homogenize sample in tray with forceps or plastic pipette with tip cut off6. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too! 7. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridge Chironomid Counts (2012, 2013) For first instar chironomids in top 1.5cm of sediment only (5 samples)1. Use sink hose to sieve sediment through 63 micrometer mesh. You may use moderate pressure to break up tubes.2. Back flush sieve contents into small deli container.3. Return label to deli cup (sticking to underside of lid works well).For later instar chironomids in the section 1.5-11.5cm (5 samples)4. Sieve with 125 micrometer mesh in the field.5. Sieve through 125micrometer mesh again in lab to reduce volume of sample.6. Transfer sample to deli container or pitfall counting tray.For all chironomid samples7. Under dissecting scope, pick through sieved contents for midge larvae. You may have to open tubes with forceps in order to check for larvae inside.8. Remove larvae with forceps while counting, and place into a vial containing 70 percent ethanol. Larvae will eventually be sorted into taxonomic groups (see key). You may sort them into taxonomic groups as you pick the larvae, or you can identify the larvae while measuring head capsules if chironomid densities are low (under 50 individuals per taxanomic group).9. For a random sample of up to 50 individuals of each taxonomic group, measure head capsule, see Chironomid size (head capsule width).10. Archive samples from each sampling date together in a single 20mL glass vial with screw cap in 70 percent ethanol and label with sample contents , Chir, sample date, lake ID, station ID, and number of cores. Chironomid Cound (2014) In 2014, the method for sampling chironomid larvae changed starting with the sample on 2014-06-27; the variable &quot;top_bottom&quot; is coded as a 2. In contrast to previous measurements, the top and bottom core samples were combined and then subsampled. Below is the pertinent section of the protocols.Chironomid samples should be counted within 24 hours of collection. This ensures that larvae are as active and easily identified as possible, and also prevents predatory chironomids from consuming other larvae. Samples should be refrigerated upon returning from the field.<strong>For first instar chironomids in top 1.5cm of sediment only (5 samples)</strong>1. Use sink hose to sieve sediment through 63&micro;m mesh. You may use moderate pressure to break up tubes.2. Back flush sieve contents using a water bottle into small deli container.3. Return label to deli cup (sticking to underside of lid works well).<strong>For larger instar chironomids in the section 1.5-11.5cm (5 samples)</strong>4. Sieve with 125&micro;m mesh in the field.5. Sieve through 125&micro;m mesh again in lab to reduce volume of sample and break up tubes.6. Transfer sample to deli container with the appropriate label.<strong>Subsample if necessary</strong>If necessary, subsample with the following protocol.a. Combine top and bottom samples from each core (1-5) in midge sample splitter.b. Homogenize sample thoroughly, collect one half in deli container, and label container with core number and &ldquo;1/2&rdquo;c. If necessary, split the half that remains in the sampler into quarters, and collect each in deli containers labeled with core number, &ldquo;1/4&rdquo;, and replicate 1 or 2d. Store all deli containers in fridge until counted, and save until all counting is complete&quot; Chironomid Size (head capsule width) 1. Obtain picked samples preserved in ethanol and empty onto petri dish.2. Sort larvae by family groups, arranging in same orientation for easy measurment.3. Set magnification to 20, diopter, x 50 times4. Take measurments for up to 50 or more individuals of each taxa. Round to nearest optical micrometer unit.5. Fill out data sheet for number of larvae in each taxa, Chironomid measurements for each taxa, date of sample, station sample was taken from, which core the sample came from, who picked the core, and your name as the measurer.6. Enter data into shared sheetSee &quot;Chironomid Counts&quot; for changes in sampling chironomid larvae in 2014.
Version Number
17

North Temperate Lakes LTER: Pelagic Macroinvertebrate Summary 1983 - current

Abstract
This is a summary of dataset NTL 13. Derived data include the mean and standard deviation of the number of each species captured as well as the mean and standard deviation of the density of individuals on both an areal and volumetric basis.Five vertical tows are done at the deepest point of each of the seven primary lakes in the Trout Lake area (Allequash, Big Muskellunge, Crystal, Sparkling, and Trout lakes and bog lakes 27-02 [Crystal Bog], and 12-15 [Trout Bog]) using a 1-mm mesh net with a 1-m wide mouth. On Trout Lake four additional sites are sampled, where depths are approximately at 10 m, 15 m, 20 m, and 25 m respectively, with three tows done at each site. Trout Lake was the only lake sampled in 2020. All samples are taken in darkness. Samples are preserved and counted, yielding numbers caught. These night tows target the large invertebrate planktivore component of the pelagic zooplankton community. Sampling Frequency: annually Number of sites: 11
Core Areas
Dataset ID
14
Date Range
-
Maintenance
ongoing
Metadata Provider
Methods
Number of individuals per square meter are calculated based on the opening of the net: 3.14159*0.25, and individuals per cubic meter are then devided by the meter depth where towing starts.Taxonomic groups counted: Chaoborus spp. (differentiating between larvae and pupae), Leptodora kinditi, Mysis relicta, and Bythotrephes longimanus.Sampling takes place at the deep hole in all lakes, in Trout Lakes 4 additional sites are sampled based on water depth not latitude/longitude along a transect from the deep hole to Rocky Reef point. Thus each lake has five samples collected, except Trout Lake, which has 17 total samples.
Short Name
NTLIP02
Version Number
31

North Temperate Lakes LTER Pelagic Macroinvertebrate Abundance 1983 - current

Abstract
Five vertical tows are done at the deepest point of each of the seven primary lakes in the Trout Lake area (Allequash, Big Muskellunge, Crystal, Sparkling, and Trout lakes and bog lakes 27-02 [Crystal Bog], and 12-15 [Trout Bog]) using a 1-mm mesh net with a 1-m wide mouth. On Trout Lake four additional sites are sampled, where depths are approximately at 10 m, 15 m, 20 m, and 25 m respectively, with three tows done at each site. Trout Lake was the only lake sampled in 2020. All samples are taken in darkness. Samples are preserved and counted, yielding numbers caught. These night tows target the large invertebrate planktivore component of the pelagic zooplankton community. Sampling Frequency: annually Number of sites: 11
Core Areas
Dataset ID
13
Date Range
-
Maintenance
ongoing
Metadata Provider
Methods
We collect night vertical tows with a 1meter diameter, 1mm mesh net from each lake in late summer. Sampling stations are at the deep hole permanent anchor in each lake. Trout Lake has four additional sampling stations. Collect five replicate tows at the same depth from the deep hole of each lake. For Trout Lake, in addition to the five replicate tows from the deep hole, take three replicate tows from four sites with depths of 10m, 15m, 20m, and 25m along a transect from the deep hole to Rocky Reef point. Thus each lake will have five samples collected, except Trout Lake, which will have 17 total samples. Samples should be taken in late summer (late August to early September). Sample after dark. The time will vary throughout the sampling period, but always wait until all skylight from the sun has disappeared. This is to give Chaoborus, which performs diel vertical migrations, time to ascend into the water column. Tie up to floats at the sampling stations. To maximize the accuracy of population estimates, the boat should be prevented from drifting. Lower the net so that the ring is at the prescribed depth. This allows us to sample most of the water column, while keeping the net off the bottom. If the bucket hits the lake bottom, rinse out the net thoroughly three times with lake water and resample, adjusting the depth accordingly. If you must make this adjustment, be sure to record the actual depth and take all remaining samples from that same depth. Once the net has been lowered to depth, allow it to settle. Raise the net at a rate of 0.5 morsec for good sampling efficiency. Upon reaching the surface with the net, rinse it by dipping it three times into the lake without submerging the top of the net. This will rinse animals trapped on the mesh into the catch bucket without introducing new animals into the sample. Reduce the volume of water in the bucket by swirling it--this unclogs the mesh and allows the water to drain. Rinse the lower 25 cm of the net in the lake again to further rinse animals into the bucket (trapped zooplankton often accumulate at the lower end of the net). Reduce the volume of water in the bucket as much as possible by swirling again. Release the butterfly clamps and pour the contents into the appropriate sample jar. Rinse the bucket using the wash bottle, swirling as before to reduce the volume, and adding the rinse water to the sample. Record the sample time (24-hour clock) on the datasheet and place sample into the cooler. Rinse the net and bucket in the lake between tows. Upon returning to the lab, rinse the net and bucket in the sink and hang net over the sink to dry. Counting Samples should be counted with a binocular microscope at about 60x total magnification. Count the entire sample; do not subsample. For ease of counting, use a petrie dish with a grid or superimpose a grid on the counting dish (a metal grid with 1 cm squares works very nicely). Samples are counted for the total numbers of the following animals: Chaoborus spp. (differentiating between larvae and pupae), Leptodora kinditi, and Mysis relicta. In addition, make a note of the relative abundance of Holopedium and Daphnia within each sample--these animals do not have to be counted, as the 1 mm mesh is too big to give a quantitative sample. As a general guideline for Holopedium and Dapnia: "very few" » 10, "few" » 50, "moderate" » 100, "many" » 500, "very many" » 1000 or more.
Short Name
NTLIP01
Version Number
32
Subscribe to leptodora