North Temperate Lakes LTER: High Frequency Meteorological and Dissolved Oxygen Data - Trout Lake Buoy 2004 - current

Abstract
The instrumented buoy on Trout Lake is equipped with a dissolved oxygen sensor, a thermistor chain, and meteorological sensors that provide fundamental information on lake thermal structure, weather conditions, and lake metabolism. Data are usually collected every 10 minutes with occasional periods of 2 minute data for short periods to answer specific questions. The D-Opto dissolved oxygen sensor is 0.5m from the lake surface. Meteorological sensors measure wind speed, wind direction, relative humidity, air temperature, photosynthetically active radiation (PAR), and barometric pressure. Starting in 2005, thermistors were placed every 0.5-1m from the surface through 14m and every 2 to 4m from 14m to the bottom of the water column at 31m. In July 2006, a new thermistor chain was deployed with thermistors placed every meter from the surface through a depth of 19 meters. After correcting for flux to or from the atmosphere and vertical mixing within the water column, high frequency measurements of dissolved gases such as carbon dioxide and oxygen can be used to estimate gross primary productivity, respiration, and net ecosystem productivity, the basic components of whole lake metabolism. Data are averaged to daily values from one minute samples for years 2005 - 2006. Daily values are computed from high resolution data starting in year 2007. Data are averaged to hourly values from one minute samples for years 2005 - 2008, Hourly values are computed from high resolution data starting in year 2009. Hourly and daily values may not be current with high resolution data in the current year. Sampling Frequency: varies for instantaneous sample. averaged to hourly and daily values from one minute samples Number of sites: 1
Core Areas
Dataset ID
117
Date Range
-
Maintenance
ongoing
Metadata Provider
Methods
The instrumented buoy on Trout Lake is equipped with a dissolved oxygen sensor, a thermistor chain, and meteorological sensors that provide fundamental information on lake thermal structure, weather conditions, and lake metabolism. Data are usually collected every 10 minutes with occasional periods of 2 minute data for short periods to answer specific questions. The D-Opto dissolved oxygen sensor is 0.5m from the lake surface. Meteorological sensors measure wind speed, wind direction, relative humidity, air temperature, photosynthetically active radiation (PAR), and barometric pressure. Starting in 2005, thermistors were placed every 0.5-1m from the surface through 14m and every 2 to 4m from 14m to the bottom of the water column at 31m. In July 2006, a new thermistor chain was deployed with thermistors placed every meter from the surface through a depth of 19 meters. After correcting for flux to or from the atmosphere and vertical mixing within the water column, high frequency measurements of dissolved gases such as carbon dioxide and oxygen can be used to estimate gross primary productivity, respiration, and net ecosystem productivity, the basic components of whole lake metabolism. Data are averaged to daily values from one minute samples for years 2005 - 2006. Daily values are computed from high resolution data starting in year 2007. Data are averaged to hourly values from one minute samples for years 2005 - 2008, Hourly values are computed from high resolution data starting in year 2009. Hourly and daily values may not be current with high resolution data in the current year. Sampling Frequency: varies for instantaneous sample. averaged to hourly and daily values from one minute samples
Short Name
TRBUOY1
Version Number
40

North Temperate Lakes LTER: High Frequency Meteorological and Dissolved Oxygen Data - Trout Bog Buoy 2003 - 2014

Abstract
The instrumented buoy on Trout Bog is equipped with a dissolved oxygen sensor, a thermistor chain, and meteorological sensors that provide fundamental information on lake thermal structure, weather conditions, and lake metabolism. Data are usually collected every 10 minutes with occasional periods of 2 minute data for short periods to answer specific questions. The D-Opto dissolved oxygen sensor is 0.5m from the lake surface, thermistors are placed every 0.5-1m throughout the water column, and meteorological sensors measure wind speed, wind direction, relative humidity, and air temperature. After correcting for flux to or from the atmosphere and vertical mixing within the water column, high frequency measurements of dissolved gases such as carbon dioxide and oxygen can be used to estimate gross primary productivity, respiration, and net ecosystem productivity, the basic components of whole lake metabolism. Sampling Frequency: varies for instantaneous sample. averaged to hourly and daily values from one minute samples Number of sites: 1
Dataset ID
69
Date Range
-
Maintenance
ongoing
Metadata Provider
Methods
The instrumented buoy on Trout Bog is equipped with a dissolved oxygen sensor, a thermistor chain, and meteorological sensors that provide fundamental information on lake thermal structure, weather conditions, and lake metabolism. Data are usually collected every 10 minutes with occasional periods of 2 minute data for short periods to answer specific questions. The D-Opto dissolved oxygen sensor is 0.5m from the lake surface, thermistors are placed every 0.5-1m throughout the water column, and meteorological sensors measure wind speed, wind direction, relative humidity, and air temperature. After correcting for flux to or from the atmosphere and vertical mixing within the water column, high frequency measurements of dissolved gases such as carbon dioxide and oxygen can be used to estimate gross primary productivity, respiration, and net ecosystem productivity, the basic components of whole lake metabolism. Sampling Frequency: varies for instantaneous sample. averaged to hourly and daily values from one minute samples
Short Name
TBBUOY1
Version Number
22

North Temperate Lakes LTER: High Frequency Meteorological - Trout Lake Buoy2 - ADCP 2005 - 2006

Abstract
This instrumented buoy on Trout Lake is equipped with a thermistor chain and meteorological sensors that provide fundamental information on lake thermal structure, weather conditions, and lake metabolism. An acoustic Doppler current profiler (ADCP) is associated with this buoy. Data are usually collected every 10 minutes with occasional periods of 2 minute data for short periods to answer specific questions. The thermistors are placed every 0.5-1m from the surface through 13m, and meteorological sensors measure relative humidity, air temperature and wind parameters. In the fall of 2005, the buoy also included 4 Greenspan dissolved oxygen sensors placed at depths from the lake surface to 10m. After correcting for flux to or from the atmosphere and vertical mixing within the water column, high frequency measurements of dissolved gases such as carbon dioxide and oxygen can be used to estimate gross primary productivity, respiration, and net ecosystem productivity, the basic components of whole lake metabolism. Sampling Frequency: varies for instantaneous sample. averaged to hourly and daily values from one minute samples Number of sites: 1
Dataset ID
120
Date Range
-
Maintenance
completed
Metadata Provider
Methods
see abstract for methods description
Publication Date
Short Name
TR2BUOY1
Version Number
11