US Long-Term Ecological Research Network

Cascade Project at North Temperate Lakes LTER cross-lakes comparison carbon Data 1988 - 2007

Abstract
Data on dissolved organic and inorganic carbon as well as particulate organic matter and the partial pressure of CO2. Samples were collected with a Van Dorn bottle. Organic samples were collected from the epilimnion, metalimnion, and hypolimnion. Inorganic samples were collected at depths corresponding to 100%, 50%, 25%, 10%, 5%, and 1% of surface irradiance, as well as one sample from the hypolimnion. Samples for the partial pressure of CO2 were collected from two meters above the lake surface (air) and just below the lake surface (water).
Contact
Core Areas
Dataset ID
278
Date Range
-
Maintenance
completed
Metadata Provider
Methods
Field and laboratory protocols can be found in the Cascade Methods Manual, found here: http://c13.valuemembers.net/Pages/methods_09.htmlPOC DOC:A: To ash filters: 1. Place filters in a foil boat and cover. Put in 450 C oven for 2 hours. B: POCorPON 1. Place a 25mm ashed GForF filter into a filter holder (grid to grid) that is attached to an Erlenmeyer flask. 2. Pour 100 - 300 ml duplicate samples from each depth (PML, meta, hypo) through 153 um mesh to remove large zooplankton. (Typically ~200mL for PML, 150 meta, 75 - 100 hypo – check previous week and adjust as necessary) 3. Filter samples at less than 200 mm Hg pressure. Remove filters from towers, fold in half, and place two replicates in one labeled Petri dish. Be sure to indic ate volume of water filtered on the Petri dish and record it on the POC log . Place dish in drying oven with the cover on loosely . 4. After filters have dried (a couple of days ), remove dish from drying oven and store in desicc ator. Analyze samples at IES. 5. Each week, make 2 blank filters by filtering 200ml of DI and processing as above. C: DOC 1. Pour 20 mL of filtrate (from POC procedure) from each lake - depth into labeled , acid washed, glass scintillati on vial s and acidify with 200 uL 2N H 2 SO 4 . Prepare t wo replicate samples for each depth. Each week, make one blank sample using 20ml of DI (filtrate from POC blanks) and 200uL 2N H 2 SO 4 . Analyze samples at IES. D. COLOR 1. Fill a 60 mL HDPE bottle with GForF filtrate from each lake - depth (from POC proced ure). Store in refrigerator until it is convenient to analyze samples on a spectrophotometer. Let samples warm up to room temperature before running on spec. 2. Turn on spectrophotometer at let it warm up for 30 minutes. Set to 440 nm. After calibrating with distilled water, rinse cuvette with 10 mL of filtrate. Remove rinse, then fill with 30 mL of filtrate and measure absorbance. Continue in this manner until all samples have been measured. (See the more detailed instructions on using the GENESYS 2 s pectrophotometer at UNDERC in Spec Instructions.doc ). 3. To estimate the amount of machine drift, measure the absorbance of distilled water after measuring sample
NTL Keyword
Version Number
21

Trout Lake USGS Water, Energy, and Biogeochemical Budgets (WEBB) Stream Data 1975-current

Abstract
This data was collected by the United States Geological Survey (USGS) for the Water, Energy, and Biogeochemical Budget Project. The data set is primarily composed of water chemistry variables, and was collected from four USGS stream gauge stations in the Northern Highland Lake District of Wisconsin, near Trout Lake. The four USGS stream gauge stations are Allequash Creek at County Highway M (USGS-05357215), Stevenson Creek at County Highway M (USGS-05357225), North Creek at Trout Lake (USGS-05357230), and the Trout River at Trout Lake (USGS-05357245), all near Boulder Junction, Wisconsin. The project has collected stream water chemistry data for a maximum of 36 different chemical parameters,. and three different physical stream parameters: temperature, discharge, and gauge height. All water chemistry samples are collected as grab samples and sent to the USGS National Water Quality Lab in Denver, Colorado. There is historic data for Stevenson Creek from 1975-1977, and then beginning again in 1991. The Trout Lake WEBB project began during the summer of 1991 and sampling of all four sites continues to date.
Creator
Dataset ID
276
Date Range
-
Maintenance
Completed.
Metadata Provider
Methods
DL is used to represent “detection limit” where known.NOTE (1): Each method listed below corresponds with a USGS Parameter Code, which is listed after the variable name. NOTE (2): If the NEMI method # is known, it is also specified at the end of each method description.NOTE (3): Some of the variables are calculated using algorithms within QWDATA. If this is the case see Appendix D of the NWIS User’s Manual for additional information. However, appendix D does not list the algorithm used by the USGS. If a variable is calculated with an algorithm the term: algor, will be listed after the variable name.anc: 99431, Alkalinity is determined in the field by using the gran function plot methods, see TWRI Book 9 Chapter A6.1. anc_1: 90410 and 00410, Alkalinity is determined by titrating the water sample with a standard solution of a strong acid. The end point of the titration is selected as pH 4.5. See USGS TWRI 5-A1/1989, p 57, NEMI method #: I-2030-89.2. c13_c12_ratio: 82081, Exact method unknown. The following method is suspected: Automated dual inlet isotope ratio analysis with sample preparation by precipitation with ammoniacal strontium chloride solution, filtration, purification, acidified of strontium carbonate; sample size is greater than 25 micromoles of carbon; one-sigma uncertainty is approximately ± 0.1 ‰. See USGS Determination of the delta13 C of Dissolved Inorganic Carbon in Water, RSIL Lab Code 1710. Chapter 18 of Section C, Stable Isotope-Ratio Methods Book 10, Methods of the Reston Stable Isotope Laboratory.3. ca, mg, mn, na, and sr all share the same method. The USGS parameter codes are listed first, then the method description with NEMI method #, and finally DL’s:ca- 00915, mg- 00925, mn- 01056, na- 00930, sr- 01080All metals are determined simultaneously on a single sample by a direct reading emission spectrometric method using an inductively coupled argon plasma as an excitation source. Samples are pumped into a crossflow pneumatic nebulizer, and introduced into the plasma through a spray chamber and torch assembly. Each analysis is determined on the basis of the average of three replicate integrations, each of which is background corrected by a spectrum shifting technique except for lithium (670.7 nm) and sodium (589.0 nm). A series of five mixed-element standards and a blank are used for calibration. Method requires an autosampler and emission spectrometry system. See USGS OF 93-125, p 101, NEMI Method #: I-1472-87.DL’s: ca- .02 mg/l, mg-.01 mg/l, mn-1.0 ug/l, na- .2 mg/l, sr- .5 ug/l4. cl, f, and so4 all share the same method. The USGS parameter codes are listed first, then the method description with NEMI method #, and finally DL’s:cl- 00940, f-00950, so4-00945All three anions (chloride, flouride, and sulfate) are separated chromatographically following a single sample injection on an ion exchange column. Ions are separated on the basis of their affinity for the exchange sites of the resin. The separated anions in their acid form are measured using an electrical conductivity cell. Anions are identified on the basis of their retention times compared with known standards. 19 The peak height or area is measured and compared with an analytical curve generated from known standards to quantify the results. See USGS OF 93-125, p 19, NEMI method #: I-2057.DL’s: cl-.2 mg/l, f-.1 mg/l, so4-.2 mg/lco2: 00405, algor, see NWIS User's Manual, QW System, Appendix D, Page 285.co3: 00445, algor.color: 00080, The color of the water is compared to that of the colored glass disks that have been calibrated to correspond to the platinum-cobalt scale of Hazen (1892), See USGS TWRI 5-A1 or1989, P.191, NEMI Method #: I-1250. DL: 1 Pt-Co colorconductance_field: 00094 and 00095, specific conductance is determined in the field using a standard YSI multimeter, See USGS TWRI 9, 6.3.3.A, P. 13, NEMI method #: NFM 6.3.3.A-SW.conductance_lab: 90095, specific conductance is determined by using a wheat and one bridge in which a variable resistance is adjusted so that it is equal to the resistance of the unknown solution between platinized electrodes of a standardized conductivity cell, sample at 25 degrees celcius, See USGS TWRI 5-A1/1989, p 461, NEMI method #: I-1780-85.dic: 00691, This test method can be used to make independent measurements of IC and TC and can also determine TOC as the difference of TC and IC. The basic steps of the procedure are as follows:(1) Removal of IC, if desired, by vacuum degassing;(2) Conversion of remaining inorganic carbon to CO<sub>2</sub> by action of acid in both channels and oxidation of total carbon to CO<sub>2</sub> by action of ultraviolet (UV) radiation in the TC channel. For further information, See ASTM Standards, NEMI method #: D6317. DL: n/adkn: 00623 and 99894, Organic nitrogen compounds are reduced to the ammonium ion by digestion with sulfuric acid in the presence of mercuric sulfate, which acts as a catalyst, and potassium sulfate. The ammonium ion produced by this digestion, as well as the ammonium ion originally present, is determined by reaction with sodium salicylate, sodium nitroprusside, and sodium hypochlorite in an alkaline medium. The resulting color is directly proportional to the concentration of ammonia present, see USGS TWRI 5-A1/1989, p 327, NEMI method #: 351.2. DL: .10 mg/Ldo: 0300, Dissolved oxygen is measured in the field with a standard YSI multimeter, NEMI Method #: NFM 6.2.1-Lum. DL: 1 mg/L.doc: 00681, The sample is acidified, purged to remove carbonates and bicarbonates, and the organic carbon is oxidized to carbon dioxide with persulfate, in the presence of an ultraviolet light. The carbon dioxide is measured by nondispersive infrared spectrometry, see USGS OF 92-480, NEMI Method #: O-1122-92. DL: .10 mg/L.don: 00607, algor, see NWIS User's Manual, QW System, Appendix D, page 291.dp: 00666 and 99893, All forms of phosphorus, including organic phosphorus, are converted to orthophosphate ions using reagents and reaction parameters identical to those used in the block digester procedure for determination of organic nitrogen plus ammonia, that is, sulfuric acid, potassium sulfate, and mercury (II) at a temperature of 370 deg, see USGS OF Report 92-146, or USGS TWRI 5-A1/1979, p 453, NEMI method #: I-2610-91. DL= .012 mg/L.fe: 01046, Iron is determined by atomic absorption spectrometry by direct aspiration of the sample solution into an air-acetylene flame, see USGS TWRI 5-A1/1985, NEMI method #: I-1381. DL= 10µg/L.h_ion: 00191, algor.h20_hardness: 00900, algor.h20_hardness_2: 00902, algor.hco3: 00440, algor.k: 00935, Potassium is determined by atomic absorption spectrometry by direct aspiration of the sample solution into an air-acetylene flame , see USGS TWRI 5-A1/1989, p 393, NEMI method #: I-1630-85. DL= .01 mg/L.n_mixed: 00600, algor.n_mixed_1: 00602, algor.n_mixed_2: 71887, algor.nh3_nh4: 00608, Ammonia reacts with salicylate and hypochlorite ions in the presence of ferricyanide ions to form the salicylic acid analog of indophenol blue (Reardon and others, 1966; Patton and Crouch, 1977; Harfmann and Crouch, 1989). The resulting color is directly proportional to the concentration of ammonia present, See USGS OF 93-125, p 125/1986 (mg/l as N), NEMI Method #: I-2525. DL= .01 mg/L.nh3_nh4_1: 71846, algor.nh3_nh4_2: 00610, same method as 00608, except see USGS TWRI 5-A1/1989, p 321. DL = .01 mg/L.nh3_nh4_3: 71845, algor.no2: 00613, Nitrite ion reacts with sulfanilamide under acidic conditions to form a diazo compound which then couples with N-1-naphthylethylenediamine dihydrochloride to form a red compound, the absorbance of which is measured colorimetrically, see USGS TWRI 5-A1/1989, p 343, NEMI method #: I-2540-90. DL= .01 mg/L.no2_2: 71856, algor.no3: 00618, Nitrate is determined sequentially with six other anions by ion-exchange chromatography, see USGS TWRI 5-A1/1989, P. 339, NEMI method #: I-2057. DL= .05 mg/L.no3_2: 71851, algor.no32: 00630, An acidified sodium chloride extraction procedure is used to extract nitrate and nitrite from samples of bottom material for this determination(Jackson, 1958). Nitrate is reduced to nitrite by cadmium metal. Imidazole is used to buffer the analytical stream. The sample stream then is treated with sulfanilamide to yield a diazo compound, which couples with N-lnaphthylethylenediamine dihydrochloride to form an azo dye, the absorbance of which is measured colorimetrically. Procedure is used to extract nitrate and nitrite from bottom material for this determination (Jackson, 1958), see USGS TWRI 5-A1/1989, p 351. DL= .1 mg/Lno32_2: 00631, same as description for no32, except see USGS OF 93-125, p 157. DL= .1 mg/L.o18_o16_ratio: 82085, Sample preparation by equilibration with carbon dioxide and automated analysis; sample size is 0.1 to 2.0 milliliters of water. For 2-mL samples, the 2-sigma uncertainties of oxygen isotopic measurement results are 0.2 ‰. This means that if the same sample were resubmitted for isotopic analysis, the newly measured value would lie within the uncertainty bounds 95 percent of the time. Water is extracted from soils and plants by distillation with toluene; recommended sample size is 1-5 ml water per analysis, see USGS Determination of the Determination of the delta (18 O or 16O) of Water, RSIL Lab Code 489.o2sat: Dissolved oxygen is measured in the field with a standard YSI multimeter, which also measures % oxygen saturation, NEMI Method #: NFM 6.2.1-Lum.ph_field: 00400, pH determined in situ, using a standard YSI multimeter, see USGS Techniques of Water-Resources Investigations, book 9, Chaps. A1-A9, Chap. A6.4 "pH," NEMI method # NFM 6.4.3.A-SW. DL= .01 pH.ph_lab: 00403, involves use of laboratory pH meter, see USGS TWRI 5-A1/1989, p 363, NEMI method #: I-1586.po4: 00660, algor, see NWIS User's Manual, QW System, Appendix D, Page 286.po4_2: 00671, see USGS TWRI 5-A1/1989, NEMI method #: I-2602. DL= .01 mg/L.s: 63719, cannot determine exact method used. USGS method code: 7704-34-9 is typically used to measure sulfur as a percentage, with an DL =.01 µg/L. It is known that the units for sulfur measurements in this data set are micrograms per liter.sar: 00931, algor, see NWIS User's Manual, QW System, Appendix D, Page 288.si: 00955, Silica reacts with molybdate reagent in acid media to form a yellow silicomolybdate complex. This complex is reduced by ascorbic acid to form the molybdate blue color. The silicomolybdate complex may form either as an alpha or beta polymorph or as a mixture of both. Because the two polymorphic forms have absorbance maxima at different wavelengths, the pH of the mixture is kept below 2.5, a condition that favors formation of the beta polymorph (Govett, 1961; Mullen and Riley, 1955; Strickland, 1952), see USGS TWRI 5-A1/1989, p 417, NEMI method #: I-2700-85. DL= .10 mg/L.spc: 00932, algor, see NWIS User's Manual, QW System, Appendix D, Page 289.tds: 70300 and 70301, A well-mixed sample is filtered through a standard glass fiber filter. The filtrate is evaporated and dried to constant weight at 180 deg C, see " Filterable Residue by Drying Oven," NEMI method #: 160.1, DL= 10 mg/l. Note: despite DL values occur in the data set that are less than 10 mg/l.tds_1: 70301, algor, see NWIS User's Manual, QW System, Appendix D, Page 289.tds_2: 70303, algor, see NWIS User's Manual, QW System, Appendix D, Page 290.tkn: 00625 and 99892, Block digester procedure for determination of organic nitrogen plus ammonia, that is, sulfuric acid, potassium sulfate, and Mercury (II) at a temperature of 370°C. See the USGS Open File Report 92-146 for further details. DL: .10 mg/L.toc: 00680, The sample is acidified, purged to remove carbonates and bicarbonates, and the organic carbon is oxidized to carbon dioxide with persulfate, in the presence of an ultraviolet light. The carbon dioxide is measured by nondispersive infrared spectrometry, see USGS TWRI 5-A3/1987, p 15, NEMI Method #: O-1122-92. DL=.10 mg/L.ton: 00605, algor, See NWIS User's Manual, QW System, Appendix D, page 286.tp: 00665 and 99891, This method may be used to analyze most water, wastewater, brines, and water-suspended sediment containing from 0.01 to 1.0 mg/L of phosphorus. Samples containing greater concentrations need to be diluted, see USGS TWRI 5-A1/1989, p 367, NEMI method #: I-4607. tp_2: 71886, algor.tpc: 00694, The basic steps of this test method are:1) Conversion of remaining IC to CO2 by action of acid, 2) Removal of IC, if desired, by vacuum degassing, 3) Split of flow into two streams to provide for separate IC and TC measurements, 4) Oxidation of TC to CO2 by action of acid-persulfate aided by ultraviolet (UV) radiation in the TC channel, 5) Detection of CO2 by passing each liquid stream over membranes that allow the specific passage of CO2 to high-purity water where change in conductivity is measured, and 6) Conversion of the conductivity detector signal to a display of carbon concentration in parts per million (ppm = mg/L) or parts per billion (ppb = ug/L). The IC channel reading is subtracted from the TC channel reading to give a TOC reading, see ASTM Standards, NEMI Method #: D5997. DL= .06 µg/L.tpn: 49570, A weighed amount of dried particulate (from water) or sediment is combusted at a high temperature using an elemental analyzer. The combustion products are passed over a copper reduction tube to covert nitrogen oxides to molecular nitrogen. Carbon dioxide, nitrogen, and water vapor are mixed at a known volume, temperature, and pressure. The concentrations of nitrogen and carbon are determined using a series of thermal conductivity detectors/traps, measuring in turn by difference hydrogen (as water vapor), carbon (as carbon dioxide), and nitrogen (as molecular nitrogen). Procedures also are provided to differentiate between organic and inorganic carbon, if desired, see USEPA Method 440, NEMI method #: 440. DL= .01 mg/L.
Short Name
TL-USGS-WEBB Data
Version Number
15

Fluxes project at North Temperate Lakes LTER: Predicting Peat Depth in a North Temperate Lake District 2008

Abstract
Peat deposits contain on the order of 1/6 of the Earth&#39;s terrestrial fixed carbon (C), but uncertainty in peat depth precludes precise estimates of peat C storage. To assess peat C in the Northern Highlands Lake District (NHLD), a approximately 7000 square km region in northern Wisconsin, United States, with 20 percent peatland by area, we sampled 21 peatlands. In each peatland, peat depth (including basal organic lake sediment, where present) was measured on a grid and interpolated to calculate mean depth. Our study addressed three questions: (1) How spatially variable is peat depth? (2) To what degree can mean peat depth be predicted from other field measurements (water chemistry, water table depth, vegetation cover, slope) and/or remotely sensed spatial data? (3) How much C is stored in NHLD peatlands? Site mean peat depth ranged from 0.1 to 5.1 m. Most of the peatlands had been formed by the in-filling of small lake basins (terrestrialization), and depths up to 15 m were observed. Mean peat depth for small peat basins could be best predicted from basin edge slope at the peatland/upland interface, either measured in the field or calculated from digital elevation (DEM) data (Adj. R2 = 0.70). Upscaling using the DEM-based regression gave a regional mean peat depth of 2.1 plus or minus 0.2 m (including approximately 0.1 to 0.4 m of organic lake sediment) and 144 plus or minus 21 Tg-C in total. As DEM data are widely available, this technique has the potential to improve C storage estimates in regions with peatlands formed primarily by terrestrialization. Number of sites: 21 Sampling Frequency: once for each site
Core Areas
Dataset ID
265
Date Range
-
Maintenance
completed
Metadata Provider
Methods
SamplingAt each location, the extent of the peatland basin was examined visually using the soils map and a long axis was defined as the longest linear stretch of peat, while a short axis was defined perpendicular to the long axis. The sample area of a given site was defined as the entire peatland basin (full basin site, N = 11) if the length of the long axis was 800 m or less. For larger peatlands, the site was defined as an area with width 150-200 m and length 400-600 m (partial basin site, N = 10) extending outward from one edge of the peatland and if possible crossing the entire short axis. Peat depth was measured throughout the area on a regular grid at intervals varying from 20-90 m depending upon the size of the site. In addition, vegetation was surveyed and peat pore water chemistry was sampled at 3 plots located at 25%, 50% and 75% of the length of the long axis of the sampling area. Peat cores were taken at the same plots for a subset of 5 sites described below, and slope at the upland-peatland interface at the edge of the site was also measured for all 11 full basin sites and 4 of the 10 partial basin sites.The depth of organic sediment (primarily peat) was measured to depth of contact with mineral surface (typically sand) throughout the sampling area using a stainless steel peat depth probe (PDP) on a regular grid at intervals varying from 20-90 m. Two different versions of the PDP were used, and intercalibrated to ensure consistency. The first consisted of 60 (1.83 m) sections of 3 800 (0.95 cm) diameter threaded steel rod, connected with hex-shaped coupling nuts. The second was a custom-made version with the same general design including length and diameter of sections, but consisted of a smooth stainless steel surface and contained an inset male and female threading system to avoid the protruding coupling nuts. The PDP was used only to determine depth to refusal and was not equipped to collect samples; thus it could not differentiate between peat and soft organic lacustrine sediment. In nearly all cases, the person using the PDP could feel contact with sand (typical glacial sediments) at depth to refusal.Peat CoresPeat cores were taken at 13 different locations, including the central plot for site 4n and each of the 3 plots for sites 7b, 9b, 12f, and 21b. At each core location, samples were taken using a Russian-style corer (50 cm length, 5cm diameter) at depths of 0.5, 1.0, 2.0, 4.0 and 6.0 m, up to the maximum depth (peat-sand interface). We examined peat color and degree of decomposition using the von Post scale in the field. Particular attention was paid to the presence/absence of gyttja at the peat-sand interface. Gyttja is a dark olive-green algae-derived gelatinous lacustrine sediment, which indicates the former presence of a clear-water lake at a given site.For each core sample (N = 45), a central 10 cm section was preserved and used to measure moisture content, bulk density, and organic matter (OM) content in the laboratory. The 10 cm section was halved vertically, and one half (between 50 and 150 g wet weight) was used for measurement of wet bulk density (rw =mw per V; where mw = wet weight and V = volume measured by water displacement). The other half was used to measure mass loss by oven-drying at 55C until the mass was stable (typically 5-10 days, measurement precision = or - 0.1 g). Volumetric moisture content was calculated as (mw md) per V and bulk density (rb)asmdper V where md =dry weight, mw = wet weight, and V = volume calculated as mw per rw. From the dried sample, a 1-3 g homogenized subsample was ashed in a muffle furnace at 440C for 8 h to determine ash-free dry weight (maf = md mash; precision plus or minus 0.01 g), and OM content (OM%) was calculated as maf per md. Finally, OM density (rOM) was calculated as rb OM%.For each of the 13 core locations, we estimated the total mass of OM by summing the product of rOM and volume over all measurement intervals. To estimate a continuous vertical distribution, rOM was interpolated linearly by depth between measurement points. The 0.25-0.5 m interval was assigned the same rOM as the 0.5 m value, while the 0-0.25 m surface interval was assigned a rOM of half of that measured at 0.5 m, to account for the lower bulk density in living recently dead Sphagnum in the acrotelm. The deepest measured rOM value was extrapolated down to a depth of 0.25 m above the base of the core, and the basal 25 cm of the core was assigned a rOM of 46 kg m3. This is equivalent to the mean value measured for gyttja, to account for the fact that the peat is grading into lower-OM gyttja and or sand at the interface with glacial till. Vertically averaged mean rOM was calculated as the total mass of OM in the core divided by the total core volume.Edge Slope in the FieldBecause many peatlands in this region formed from in-filling of lakes, we hypothesized that local geomorphology, specifically slope at the peatland margin (peatland-upland interface), might be a good indicator of peatland depth. At a subset of 15 sites (including all 11 full basin sites) we measured slope at the peatland-upland interface (Edge Slope in the Field, ESF). At full basin sites, ESF readings were taken at 8 peatland-upland interface locations distributed evenly around the edge of the site. At partial basin sites, measurements were only taken at those site edges that were adjacent to upland, resulting in fewer than 8 locations at each site. At each location, a Suunto clinometer was used to measure slope (%) from the peatland-upland interface oriented up the steepest upland slope at a distance of 5 m, 10 m, 20 m and 30 m, and these four values were averaged to give a single slope value for each location. The precision of individual measurements was plus or minus 0.3% slope (mean SD of replicate measurements). The values used for statistical analysis were site mean (ESFmean) and maximum (ESFmax) of location slopes.VegetationWe hypothesized that the surface vegetation characteristics might be related to peat depth, either directly (due to differential contributions of plant species to decomposition rates and water-holding capacity), or indirectly by responding to local environmental characteristics (e.g., water table, groundwater flow) that also influence peat formation. Vegetation was surveyed following a modification of the U.S. Forest Service Forest Inventory and Analysis (FIA) protocol. At each plot, a circular sampling area with 7.3 m radius was laid out, with 3 linear transects extending from the center to the perimeter at 0, 120 and 240 degrees from compass north. Within the circular plot, all trees with diameter at breast height (DBH) of 2.5 to 4.9 cm were counted as saplings and their species recorded, while species and DBH were recorded for all trees with DBH at 5 cm. Basal area for each tree species in units of m2 ha-1 was calculated by summing the DBH of all individual trees and normalizing by plot area. The mean height and intersection length of each of 4 categories of shrub (alder, bog birch, ericaceous or tree seedling) were recorded for woody vegetation of height greater than 50 cm (but DBH less than 2.5 cm) that intersected any of the linear transects. Shrub percent cover was estimated for each category by dividing the intercepted length by the total transect length. Coarse woody debris (CWD) with length greater than 1 m that intersected any of the linear transects with diameter greater than 5 cm was tallied; small end diameter (down to 5 cm), large end diameter, and length of each piece of CWD was recorded and used to calculate volume as described by Waddell [2002]. Finally, three ground-layer quadrats (1 m2) were laid out, 1 each adjacent to the 3 linear transects spanning a distance of 4 to 5 m from the center point. Within each quadrat, percent cover was recorded for each of 8 commonly occurring ground cover types: bare ground, ericaceous shrubs, ferns, forbs, graminoids, Sphagnum mosses, other mosses, and other woody vegetation (tree seedlings). Values for the 3 quadrats were averaged to give a plot mean cover of each ground cover type.
Short Name
PEAT1
Version Number
24

Parameter: Organic Carbon

Samples for organic and inorganic carbon are collected together with a peristaltic pump and tubing and in-line filtered, if necessary, (through a 0.40 micron polycarbonate filter) into glass 24 ml vials (that are compatible with the carbon analyzer autosampler), and capped with septa, leaving no head space.

Parameter: Inorganic Carbon

Samples for inorganic and organic carbon are collected together with a peristaltic pump and tubing and in-line filtered, if necessary, (through a 0.40 micron polycarbonate filter) into glass, 24 ml vials (that are compatible with the carbon analyzer autosampler), and capped with septa, leaving no head space.

North Temperate Lakes LTER: Groundwater Chemistry 1984 - current

Abstract
Water chemistry is measured annually in 11 monitoring wells to characterize regional groundwater chemistry in the Trout Lake area. The chemical parameters measured include pH, conductivity, total alkalinity, dissolved inorganic and organic carbon, total nitrogen, nitrate, ammonia, total phosphorus, calcium, magnesium, sodium, potassium, chloride, sulfate, iron, manganese, total silica and dissolved reactive silica. Chemical data are available at a quarterly sampling frequency for some years. In addition (see related data set - Groundwater Level), water levels in 37 monitoring wells are measured several times per year. The wells are scattered throughout the Trout Lake hydrological basin and the data are used to calibrate and test regional groundwater flow models. Sampling Frequency: annually - with some earlier data from quarterly sampling Number of sites: 11
Dataset ID
10
Date Range
-
Maintenance
ongoing
Metadata Provider
Methods
Ammonium, Nitrate, Nitrit Samples for ammonium and nitrate or nitrite are collected together with a peristaltic pump and tubing and in-line filtered (through a 0.40 micron polycarbonate filter) into new, 20 ml HDPE plastic containers with conical caps. The samples are stored frozen until analysis, which should occur within 6 months. The samples are analyzed for ammonium (and nitrateornitrite) simultaneously by automated colorimetric spectrophotometry, using a segmented flow autoanalyzer. Ammonium is determined by utilizing the Berthelot Reaction, producing a blue colored indophenol compound, where the absorption is monitored at 660 nm. The detection limit for ammonium is approximately 3 ppb and the analytical range for the method extends to 4000 ppb. The detection limit for nitrateornitrite is approximately 2 ppb and the analytical range for the method extends to 4000 ppb. Method Log: Prior to January 2006 samples, ammonium was determined on a Technicon segmented flow autoanalyzer. From 2006 to present, ammonium is determined by an Astoria-Pacific Astoria II segmented flow autoanalyzer. Chloride, Sulfate Samples for chloride and sulfate are collected together with a peristaltic pump and tubing and in-line filtered (through a 0.40 micron polycarbonate filter) into new, 20 ml HDPE plastic containers with conical caps. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 6 months. The samples are analyzed for chloride (and sulfate) simultaneously by Ion Chromatography, using a hydroxide eluent. The detection limit for chloride is approximately 0.01 ppm and the analytical range for the method extends to 100 ppm. The detection limit for sulfate is approximately 0.01 ppm and the analytical range for the method extends to 60 ppm. Method Log: Prior to January 1998 samples, chloride was determined on a Dionex DX10 Ion Chromatograph, using a chemical fiber suppressor. From 1998 to 2011, chloride was determined by a Dionex model DX500, using an electro-chemical suppressor. From January 2011 until present, chloride is determined by a Dionex model ICS 2100 using an electro-chemical suppressor. Calcium, magnesium, sodium, potassium, iron, and manganese Samples for calcium analysis (as well as dissolved nitrogen and phosphorus, magnesium, sodium, potassium, iron, and manganese) are collected together with a peristaltic pump and tubing and in-line filtered (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 ml of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. Calcium, as well as magnesium, sodium, potassium, iron, and manganese are analyzed simultaneously on an optical inductively-coupled plasma emission spectrophotometer (ICP-OES). The acidified samples are directly aspirated into the instrument without a digestion. Calcium is analyzed at 317.933 nm and at 315.887 nm and viewed axially for low-level analysis and radially for high level analysis. The detection limit for calcium is 0.06 ppm with an analytical range of the method extends to 50 ppm. The detection limit for iron is 0.02 ppm with an analytical range of the method extends to 20 ppm. The detection limit for magnesium is 0.03 ppm with an analytical range of the method extends to 50 ppm. The detection limit for manganese is 0.01 ppm with an analytical range of the method extends to 2 ppm. The detection limit for potassium is 0.06 ppm with an analytical range of the method extends to 10 ppm. The detection limit for sodium is 0.06 ppm with an analytical range of the method extends to 50 ppm. Method Log: Prior to January 2002, calcium, magnesium, sodium, potassium, iron, and manganese were determined on a Perkin-Elmer model 503 Atomic Absorption Spectrophotometer. Lanthanum at a 0.8percent concentration was added as a matrix modifier to suppress chemical interferences. From January 2002 to present, samples are analyzed for calcium on a Perkin-Elmer model 4300 DV ICP. Inorganic and organic carbon Samples for inorganic and organic carbon are collected together with a peristaltic pump and tubing and in-line filtered, if necessary, (through a 0.40 micron polycarbonate filter) into glass, 24 ml vials (that are compatible with the carbon analyzer autosampler), and capped with septa, leaving no head space. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 2-3 weeks. The detection limit for inorganic carbon is 0.15 ppm, and the analytical range for the method is 60 ppm. The detection limit for organic carbon is 0.30 ppm and the analytical range for the method is 30 ppm. Method Log: Prior to May 2006 samples, inorganic carbon was analyzed by phosphoric acid addition on an OI Model 700 Carbon Analyzer. From May 2006 to present, inorganic carbon is still analyzed by phosphoric acid addition, but on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer. Method Log: Prior to May 2006 samples, organic carbon was analyzed by heated persulfate digestion on an OI Model 700 Carbon Analyzer. From May 2006 to present, Organic carbon is analyzed by combustion, on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer. Dissolved reactive silicon Samples for silicon are collected with a peristaltic pump and tubing and in-line filtered (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 ml of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. Dissolved reactive silica is determined by the Heteropoly Blue Method and the absorption is measured at 820 nm. The detection limit for silicon is 6 ppb and the analytical range is 15000 ppb. Method Log These determinations were performed manually using a Bausch and Lomb Spectrophotometer from the beginning of the project until April 1984. From 1984 through 2005, dissolved reactive silicon was determined on a Technicon Auto Analyzer II. From January 2006 to present, samples are run on an Astoria-Pacific Astoria II Autoanalyzer. total and dissolved nitrogen and phosphorus Samples for total and dissolved nitrogen and phosphorus analysis are collected together with a peristaltic pump and tubing and in-line filtered, when necessary, (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 mL of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. The samples must first be prepared for analysis by adding an NaOH–Persulfate digestion reagent and heated for an hour at 120 degrees C and 18-20 psi in an autoclave. The samples are analyzed for total nitrogen and total phosphorus simultaneously by automated colorimetric spectrophotometry, using a segmented flow autoanalyzer. Total nitrogen is determined by utilizing the automated cadmium reduction method, as described in Standard Methods, where the absorption is monitored at 520 nm. The detection limit for total and dissolved nitrogen is approximately 21 ppb and the analytical range for the method extends to 2500 ppb. The detection limit for total phosphorus is approximately 3 ppb and the analytical range for the method extends to 800 ppb. Method Log: Prior to January 2006 samples, total nitrogen was determined on a Technicon segmented flow autoanalyzer. From 2006 to present, total nitrogen is determined by an Astoria-Pacific Astoria II segmented flow autoanalyzer. pH We sample at the deepest part of the lake using a peristaltic pump and tubing, monthly during open water and approximately every five weeks during ice cover. We collect two types of pH samples at each sampling depth: one in 20ml vials with cone cap inserts to exclude all air from the vial, and one in 125ml bottles to be air equilibrated before analysis. The depths for sample collection are based on thermal stratification: top and bottom of the epilimnion, mid thermocline, and top, middle,and bottom of the hypolimnion. During mixis we sample at the surface, mid water column, and bottom. We analyze for pH the same day that samples are collected, keeping them cold and dark until just before analysis. Samples are warmed to room temperature in a dark container, and the air equilibrated samples are bubbled with outside air for at least 15 minutes prior to measurement. We measure pH using a Radiometer combination pH electrode and Orion 4Star pH meter. Protocol Log: 1981-1988 -- used a PHM84 Research pH meter. 1986 -- began analyzing air equilibrated pH. 1988 - July 2010 -- used an Orion model 720 pH meter.</p>
Short Name
NTLGW02
Version Number
23

North Temperate Lakes LTER: Chemical Limnology of Primary Study Lakes: Nutrients, pH and Carbon 1981 - current

Abstract
Parameters characterizing the nutrient chemistry of the eleven primary lakes (Allequash, Big Muskellunge, Crystal, Sparkling, and Trout lakes, unnamed lakes 27-02 [Crystal Bog] and 12-15 [Trout Bog], Mendota, Monona, Wingra, and Fish) are measured at multiple depths throughout the year. These parameters include total nitrogen, total dissolved nitrogen, nitrite+nitrate-N, ammonium-N, total phosphorus, total dissolved phosphorus, dissolved reactive phosphorus (only in the southern lakes and not in Wingra and Fish after 2003), bicarbonate-reactive filtered and unfiltered silica (both discontinued in 2003), dissolved reactive silica, pH, air equilibrated pH (discontinued in 2014 in the northern lakes and in 2020 in the southern lakes), total alkalinity, total inorganic carbon, dissolved inorganic carbon, total organic carbon, dissolved organic carbon, and total particulate matter (only in the northern lakes in this data set; total particulate matter in southern lakes starting in 2000 is available in a separate dataset). Sampling Frequency: Northern lakes- monthly during ice-free season -- every 5 weeks during ice-covered season. Southern lakes- Southern lakes samples are collected every 2-4 weeks during the summer stratified period, at least monthly during the fall, and typically only once during the winter, depending on ice conditions. Number of sites: 11
Note that years 2020 & 2021 are not complete but we are publishing the data that we have. The dataset will be updated as new data is received.
Dataset ID
1
Date Range
-
DOI
10.6073/pasta/cc6f0e4d317d29200234c7243471472a
Maintenance
ongoing
Metadata Provider
Methods
Inorganic and organic carbon: Samples for inorganic and organic carbon are collected together with a peristaltic pump and tubing and in-line filtered, if necessary, (through a 0.40 micron polycarbonate filter) into glass, 24 ml vials (that are compatible with the carbon analyzer autosampler), and capped with septa, leaving no head space. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 2-3 weeks. The detection limit for inorganic carbon is 0.15 ppm, and the analytical range for the method is 60 ppm. The detection limit for organic carbon is 0.30 ppm and the analytical range for the method is 30 ppm. Method Log: Prior to May 2006 samples, inorganic carbon was analyzed by phosphoric acid addition on an OI Model 700 Carbon Analyzer. From May 2006 to present, inorganic carbon is still analyzed by phosphoric acid addition, but on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer. Method Log: Prior to May 2006 samples, organic carbon was analyzed by heated persulfate digestion on an OI Model 700 Carbon Analyzer. From May 2006 to present, Organic carbon is analyzed by combustion, on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer. Dissolved reactive silica Samples for silica are collected with a peristaltic pump and tubing and in-line filtered (through a 45 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 ml of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. Dissolved reactive silica is determined by the Heteropoly Blue Method and the absorption is measured at 820 nm. The detection limit for silica is 6 ppb and the analytical range is 15000 ppb. Method Log These determinations were performed manually using a Bausch and Lomb Spectrophotometer from the beginning of the project until April 1984. From 1984 through 2005, dissolved reactive silica was determined on a Technicon Auto Analyzer II. From January 2006 to present, samples are run on an Astoria-Pacific Astoria II Autoanalyzer. total and dissolved nitrogen and phosphorus Samples for total and dissolved nitrogen and phosphorus analysis are collected together with a peristaltic pump and tubing and in-line filtered, when necessary, (through a 45 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 mL of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. The samples must first be prepared for analysis by adding an NaOH–Persulfate digestion reagent and heated for an hour at 120 degrees C and 18-20 psi in an autoclave. The samples are analyzed for total nitrogen and total phosphorus simultaneously by automated colorimetric spectrophotometry, using a segmented flow autoanalyzer. Total nitrogen is determined by utilizing the automated cadmium reduction method, as described in Standard Methods, where the absorption is monitored at 520 nm. The detection limit for total and dissolved nitrogen is approximately 21 ppb and the analytical range for the method extends to 2500 ppb. The detection limit for total phosphorus is approximately 3 ppb and the analytical range for the method extends to 800 ppb. Method Log: Prior to January 2006 samples, total nitrogen was determined on a Technicon segmented flow autoanalyzer. From 2006 to present, total nitrogen is determined by an Astoria-Pacific Astoria II segmented flow autoanalyzer.
Short Name
NTLCH01
Version Number
59

Little Rock Lake Experiment at North Temperate Lakes LTER: Nutrients 1996 - 2000

Abstract
The Little Rock Acidification Experiment was a joint project involving the USEPA (Duluth Lab), University of Minnesota-Twin Cities, University of Wisconsin-Superior, University of Wisconsin-Madison, and the Wisconsin Department of Natural Resources. Little Rock Lake is a bi-lobed lake in Vilas County, Wisconsin, USA. In 1983 the lake was divided in half by an impermeable curtain and from 1984-1989 the northern basin of the lake was acidified with sulfuric acid in three two-year stages. The target pHs for 1984-5, 1986-7, and 1988-9 were 5.7, 5.2, and 4.7, respectively. Starting in 1990 the lake was allowed to recover naturally with the curtain still in place. Data were collected through 2000. The main objective was to understand the population, community, and ecosystem responses to whole-lake acidification. Funding for this project was provided by the USEPA and NSF. Parameters characterizing the nutrient chemistry of the treatment and reference basins of Little Rock Lake are measured at one station in the deepest part of each basin at the top and bottom of the epilimnion, mid-thermocline, and top, middle, and bottom of the hypolimnion. These parameters include total nitrogen, total dissolved nitrogen, nitrate, ammonia, total phosphorus, total dissolved phosphorus, dissolved reactive phosphorus, bicarbonite-reactive filtered and unfiltered silica, dissolved reactive silica, total inorganic carbon, dissolved inorganic carbon, total organic carbon, dissolved organic carbon, and total particulate matter. Sampling Frequency: varies - Number of sites: 2
Dataset ID
246
Date Range
-
Maintenance
completed
Metadata Provider
Methods
Inorganic and organic carbonSamples for inorganic and organic carbon are collected together with a peristaltic pump and tubing and in-line filtered, if necessary, (through a 0.40 micron polycarbonate filter) into glass, 24 ml vials (that are compatible with the carbon analyzer autosampler), and capped with septa, leaving no head space. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 2-3 weeks.The detection limit for inorganic carbon is 0.15 ppm, and the analytical range for the method is 60 ppm.The detection limit for organic carbon is 0.30 ppm and the analytical range for the method is 30 ppm.Method Log: Prior to May 2006 samples, inorganic carbon was analyzed by phosphoric acid addition on an OI Model 700 Carbon Analyzer. From May 2006 to present, inorganic carbon is still analyzed by phosphoric acid addition, but on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer.Method Log: Prior to May 2006 samples, organic carbon was analyzed by heated persulfate digestion on an OI Model 700 Carbon Analyzer. From May 2006 to present, Organic carbon is analyzed by combustion, on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer.Dissolved reactive siliconSamples for silicon are collected with a peristaltic pump and tubing and in-line filtered (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 ml of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius.Dissolved reactive silica is determined by the Heteropoly Blue Method and the absorption is measured at 820 nm.The detection limit for silicon is 6 ppb and the analytical range is 15000 ppb.Method Log These determinations were performed manually using a Bausch and Lomb Spectrophotometer from the beginning of the project until April 1984. From 1984 through 2005, dissolved reactive silicon was determined on a Technicon Auto Analyzer II. From January 2006 to present, samples are run on an Astoria-Pacific Astoria II Autoanalyzer.total and dissolved nitrogen and phosphorusSamples for total and dissolved nitrogen and phosphorus analysis are collected together with a peristaltic pump and tubing and in-line filtered, when necessary, (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 mL of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius.The samples must first be prepared for analysis by adding an NaOH&ndash;Persulfate digestion reagent and heated for an hour at 120 degrees C and 18-20 psi in an autoclave.The samples are analyzed for total nitrogen and total phosphorus simultaneously by automated colorimetric spectrophotometry, using a segmented flow autoanalyzer. Total nitrogen is determined by utilizing the automated cadmium reduction method, as described in Standard Methods, where the absorption is monitored at 520 nm.The detection limit for total and dissolved nitrogen is approximately 21 ppb and the analytical range for the method extends to 2500 ppb.The detection limit for total phosphorus is approximately 3 ppb and the analytical range for the method extends to 800 ppb.Method Log: Prior to January 2006 samples, total nitrogen was determined on a Technicon segmented flow autoanalyzer. From 2006 to present, total nitrogen is determined by an Astoria-Pacific Astoria II segmented flow autoanalyzer.
Short Name
LRNUTR1
Version Number
4
Subscribe to carbon