US Long-Term Ecological Research Network

LTREB Biological Limnology at Lake Myvatn 2012-current

Abstract
These data are part of a long-term monitoring program in the central part of Myvatn that represents the dominant habitat, with benthos consisting of diatomaceous ooze. The program was designed to characterize import benthis and pelagic variables across years as midge populations varied in abundance. Starting in 2012 samples were taken at roughly weekly inervals during June, July, and August, which corresponds to the summer generation of the dominant midge,<em>Tanytarsus gracilentus</em>.
Creator
Dataset ID
296
Date Range
-
Maintenance
Ongoing
Metadata Provider
Methods
Benthic Chlorophyll Field sampling (5 samples) (2012, 2013)1. Take 5 cores from the lake2. Cut the first 0.75 cm (1 chip) of the core with the extruder and place in deli container. Label with date and core number.3. Place deli containers into opaque container (cooler) and return to lab. This is the same sample that is used for the organic matter analysis.In 2014, the method for sampling benthic chlorophyll changed. The calculation of chlorophyll was changed to reflect the different area sampled. Below is the pertinent section from the methods protocols. Processing after the collection of the sample was not changed.Take sediment samples from the 5 cores collected for sediment characteristics. Take 4 syringes of sediment with 10mL syringe (15.96mm diameter). Take 4-5cm of sediment. Then, remove bottom 2cm and place top 2cm in the film canister.Filtering1. Measure volume of material in deli container with 60mL syringe and record.2. Homogenize and take 1mL sample with micropipette. The tip on the micropipette should be cut to avoid clogging with diatoms. Place the 1mL sample in a labeled film canister. Freeze sample at negative 20 degrees Celsius unless starting methanol extraction immediately.3. Add 20mL methanol. This methanol can be kept cool in the fridge, although then you will need a second bottle of methanol for the fluorometer. Shake for 5 sec.4. After 6-18 hours, shake container for 5 sec.Fluorometer1. Allow the film canisters to sit at room temperature for approximately 15 min to avoid excessive condensation on the glass tubes. Shake tubes for 5 sec after removing from fridge but then be careful to let them settle before removing sample.2. Record the sample information for all of the film canisters on the data sheet.3. Add 4mL of sample to a 13x100mL glass tube.4. Insert the sample into the fluorometer and record the reading in the Fluor Before Acid column. The sample reading should be close to one of the secondary solid standards (42ug/L or 230ug/L), if not, dilute the sample to within 25 per cent of the secondary solid standards (30-54ug/L or 180-280ug/L). It is a good idea to quickly check 2mL of a sample that is suspected to be too high to get an idea if other samples may need to be diluted. If possible, read the samples undiluted.5. If a sample needs to be diluted, use a 1000 microLiter pipette and add 2mL of methanol to a tube followed by 2mL of undiluted sample. Gently invert the tube twice and clean the bottom with a paper towel before inserting it into the fluorometer. If the sample is still outside of the ranges above, combine 1 mL of undiluted sample with 3 mL of methanol. Be sure to record the dilution information on the data sheet.6. Acidify the sample by adding 120microLiters of 0.1 N HCl (30microLiters for every one mL of sample). Then gently invert the sample and wait 90 seconds (we used 60 seconds in 2012, the protocol said 90) before putting the sample into the fluorometer and recording the reading in the Fluor After Acid column. Be sure to have acid in each tube for exactly the same amount of time. This means doing one tube at a time or spacing them 30-60 seconds apart.7. Double check the results and redo samples, which have suspicious numbers. Make sure that the after-acidification values make sense when compared to the before acidification value (the before acid/after acid ratio should be approximately the same for all samples).Clean up1. Methanol can be disposed of down the drain as long as at least 50 times as much water is flushed.2. Rinse the film canisters and lids well with tap water and scrub them out with a bottle brush making sure to remove any remaining filter paper. Give a final rinse with distilled water. Pelagic Chlorophyll Field sampling (5 samples)1. Take 2 samples at each of three depths, 1, 2, and 3m with Arni&rsquo;s zooplankton trap. For the 1m sample, drop the trap to the top of the chain. Each trap contains about 2.5L of water when full. 2. Empty into bucket by opening the bottom flap with your hand.3. Take bucket to lab.Filtering1. Filter 1L water from integrated water sample (or until the filter is clogged) through the 47 mm GF/F filter. The pressure used during filtering should be low ( less than 5 mm Hg) to prevent cell breakage. Filtering and handling of filters should be performed under dimmed lighting.2. Remove the filter with forceps, fold it in half (pigment side in), and put it in the film canister. Take care to not touch the pigments with the forceps.3. Add 20mL methanol. This methanol can be kept cool in the fridge, although then you will need a second bottle of methanol for the fluorometer. Shake for 5 sec. and place in fridge.4. After 6-18 hours, shake container for 5 sec.5. Analyze sample in fluorometer after 24 hours.Fluorometer1. Allow the film canisters to sit at room temperature for approximately 15 min to avoid excessive condensation on the glass tubes. Shake tubes for 5 sec after removing from fridge but then be careful to let them settle before removing sample.2. Record the sample information for all of the film canisters on the data sheet.3. Add 4mL of sample to a 13x100mL glass tube.4. Insert the sample into the fluorometer and record the reading in the Fluor Before Acid column. The sample reading should be close to one of the secondary solid standards (42ug/L or 230ug/L), if not, dilute the sample to within 25 percent of the secondary solid standards (30-54ug/L or 180-280ug/L). It is a good idea to quickly check 2mL of a sample that is suspected to be too high to get an idea if other samples may need to be diluted. If possible, read the samples undiluted.5. If a sample needs to be diluted, use a 1000uL pipette and add 2mL of methanol to a tube followed by 2mL of undiluted sample. Gently invert the tube twice and clean the bottom with a paper towel before inserting it into the fluorometer. If the sample is still outside of the ranges above, combine 1 mL of undiluted sample with 3 mL of methanol. Be sure to record the dilution information on the data sheet.6. Acidify the sample by adding 120 microLiters of 0.1 N HCl (30 microLiters for every one mL of sample). Then gently invert the sample and wait 90 seconds (we used 60 seconds in 2012, the protocol said 90) before putting the sample into the fluorometer and recording the reading in the Fluor After Acid column. Be sure to have acid in each tube for exactly the same amount of time. This means doing one tube at a time or spacing them 30-60 seconds apart.7. Double check the results and redo samples, which have suspicious numbers. Make sure that the after-acidification values make sense when compared to the before acidification value (the before acid/after acid ratio should be approximately the same for all samples).Clean up1. Methanol can be disposed of down the drain as long as at least 50 times as much water is flushed.2. Rinse the film canisters and lids well with tap water and scrub them out with a bottle brush making sure to remove any remaining filter paper. Give a final rinse with distilled water. Pelagic Zooplankton Counts Field samplingUse Arni&rsquo;s zooplankton trap (modified Schindler) to take 2 samples at each of 1, 2, and 3m (6 total). For the 1m sample, drop the trap to the top of the chain. Each trap contains about 2.5L of water when full. Integrate samples in bucket and bring back to lab for further processing.Sample preparation in lab1. Sieve integrated plankton tows through 63&micro;m mesh and record volume of full sample2. Collect in Nalgene bottles and make total volume to 50mL3. Add 8 drops of lugol to fix zooplankton.4. Label bottle with sample date, benthic or pelagic zooplankton, and total volume sieved. Samples can be stored in the fridge until time of countingCounting1. Remove sample from fridge2. Sieve sample with 63 micro meter mesh over lab sink to remove Lugol&rsquo;s solution (which vaporizes under light)3. Suspend sample in water in sieve and flush from the back with squirt bottle into counting tray4. Homogenize sample with forceps or plastic pipette with tip cut off5. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted as well.6. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridgeSubsamplingIf homogenized original sample contains more than 500 individuals in the first line of counting tray, you may subsample under the following procedure.1. Return original sample to Nalgene bottle and add water to 50mL2. Homogenize sample by swirling Nalgene bottle3. Collect 10mL of zooplankton sample with Hensen-Stempel pipette4. Empty contents of Hensen-Stempel pipette into large Bogorov tray5. Homogenize sample in tray with forceps or plastic pipette with tip cut off6. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too! 7. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridge Benthic Microcrustacean Counts Field samplingLeave benthic zooplankton sampler for 24h. Benthic sampler consists of 10 inverted jars with funnel traps in metal grid with 4 feet. Set up on bench using feet (on side) to get a uniform height of the collection jars (lip of jar = 5cm above frame). Upon collection, pull sampler STRAIGHT up, remove jars, homogenize in bucket and bring back to lab. Move the boat slightly to avoid placing sampler directly over cored sediment.Sample preparation in lab1. Sieve integrated samples through 63 micrometer mesh and record volume of full sample2. Collect in Nalgene bottles and make total volume to 50mL3. Add 8 drops of lugol to fix zooplankton.4. Label bottle with sample date, benthic or pelagic zooplankton, and total volume sieved. Samples can be stored in the fridge until time of countingCounting1. Remove sample from fridge2. Sieve sample with 63 micrometer mesh over lab sink to remove Lugol&rsquo;s solution (which vaporizes under light)3. Suspend sample in water in sieve and flush from the back with squirt bottle into counting tray4. Homogenize sample with forceps or plastic pipette with tip cut off5. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too!6. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridgeSubsamplingIf homogenized original sample contains more than 500 individuals in the first line of counting tray, you may subsample under the following procedure.1. Return original sample to Nalgene bottle and add water to 50mL2. Homogenize sample by swirling Nalgene bottle3. Collect 10mL of zooplankton sample with Hensen-Stempel pipette4. Empty contents of Hensen-Stempel pipette into large Bogorov tray5. Homogenize sample in tray with forceps or plastic pipette with tip cut off6. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too! 7. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridge Chironomid Counts (2012, 2013) For first instar chironomids in top 1.5cm of sediment only (5 samples)1. Use sink hose to sieve sediment through 63 micrometer mesh. You may use moderate pressure to break up tubes.2. Back flush sieve contents into small deli container.3. Return label to deli cup (sticking to underside of lid works well).For later instar chironomids in the section 1.5-11.5cm (5 samples)4. Sieve with 125 micrometer mesh in the field.5. Sieve through 125micrometer mesh again in lab to reduce volume of sample.6. Transfer sample to deli container or pitfall counting tray.For all chironomid samples7. Under dissecting scope, pick through sieved contents for midge larvae. You may have to open tubes with forceps in order to check for larvae inside.8. Remove larvae with forceps while counting, and place into a vial containing 70 percent ethanol. Larvae will eventually be sorted into taxonomic groups (see key). You may sort them into taxonomic groups as you pick the larvae, or you can identify the larvae while measuring head capsules if chironomid densities are low (under 50 individuals per taxanomic group).9. For a random sample of up to 50 individuals of each taxonomic group, measure head capsule, see Chironomid size (head capsule width).10. Archive samples from each sampling date together in a single 20mL glass vial with screw cap in 70 percent ethanol and label with sample contents , Chir, sample date, lake ID, station ID, and number of cores. Chironomid Cound (2014) In 2014, the method for sampling chironomid larvae changed starting with the sample on 2014-06-27; the variable &quot;top_bottom&quot; is coded as a 2. In contrast to previous measurements, the top and bottom core samples were combined and then subsampled. Below is the pertinent section of the protocols.Chironomid samples should be counted within 24 hours of collection. This ensures that larvae are as active and easily identified as possible, and also prevents predatory chironomids from consuming other larvae. Samples should be refrigerated upon returning from the field.<strong>For first instar chironomids in top 1.5cm of sediment only (5 samples)</strong>1. Use sink hose to sieve sediment through 63&micro;m mesh. You may use moderate pressure to break up tubes.2. Back flush sieve contents using a water bottle into small deli container.3. Return label to deli cup (sticking to underside of lid works well).<strong>For larger instar chironomids in the section 1.5-11.5cm (5 samples)</strong>4. Sieve with 125&micro;m mesh in the field.5. Sieve through 125&micro;m mesh again in lab to reduce volume of sample and break up tubes.6. Transfer sample to deli container with the appropriate label.<strong>Subsample if necessary</strong>If necessary, subsample with the following protocol.a. Combine top and bottom samples from each core (1-5) in midge sample splitter.b. Homogenize sample thoroughly, collect one half in deli container, and label container with core number and &ldquo;1/2&rdquo;c. If necessary, split the half that remains in the sampler into quarters, and collect each in deli containers labeled with core number, &ldquo;1/4&rdquo;, and replicate 1 or 2d. Store all deli containers in fridge until counted, and save until all counting is complete&quot; Chironomid Size (head capsule width) 1. Obtain picked samples preserved in ethanol and empty onto petri dish.2. Sort larvae by family groups, arranging in same orientation for easy measurment.3. Set magnification to 20, diopter, x 50 times4. Take measurments for up to 50 or more individuals of each taxa. Round to nearest optical micrometer unit.5. Fill out data sheet for number of larvae in each taxa, Chironomid measurements for each taxa, date of sample, station sample was taken from, which core the sample came from, who picked the core, and your name as the measurer.6. Enter data into shared sheetSee &quot;Chironomid Counts&quot; for changes in sampling chironomid larvae in 2014.
Version Number
17

LTREB Chemical and Physical Limnology at Lake Myvatn 2012-current

Abstract
These data are part of a long-term monitoring program at station 33 in the central part of Myvatn that represents the dominant habitat, with benthos consisting of diatomaceous ooze. The program was designed to characterize import benthis and pelagic variables across years as midge populations varied in abundance. Starting in 2012 samples were taken at roughly weekly inervals during June, July, and August, which corresponds to the summer generation of the dominant midge, Tanytarsus gracilentus.
Creator
Dataset ID
287
Date Range
-
Maintenance
Ongoing
Metadata Provider
Methods
Water Profile1. Take Light, DO, pH, Temp profile every 0.5mUse YSI DO probe, pH meter, and Li Cor light meter. Take the light profile from the sunny side of the boat.2. Take Secchi depthLower Secchi disk slowly until you can never see clear boundaries between white and black quarters, record this distance to the surface of the water as lower Secchi disk observation. Then pull the Secchi up until you can always see clear boundaries between white and black quarters, record this distance to the surface as the upper Secchi observation.Benthic Net Primary Production1. Measure light, temperature, percentDO, DO, and pH at 0.5m intervals at the sampling location.2. Take 10 clean/undisturbed cores. Try to get a uniform distance between the sediment and top of tube, so the cores have the same volume of water. Cover in boat with tarp to exclude light.3. Collect water from the shore of the boat and measure temp, percentDO, and DO. Save in bucket.4. Measure light intensity at 0 (out) and 0.5m depth where the cores will be incubated.5. Set up HOBO light recorder on the incubator.6. For each tube, take initial temp, percentDO, and DO. Before taking DO measurement, move the DO probe up and down three times to ensure no DO gradient (but do not disturb sediment). Add, slowly and without bubbling, 10 to 20mL of water (just the amount needed) to the core from bucket (number 3) to ensure no air space, and replace the stopper. Measure the distance from sediment to bottom of stopper to the nearest 0.5cm (column_depth).7. Place cores 1, 3, 5, and 7 in dark chambers (opaque tubes), so there are 4 dark and 6 light treatments.8. Incubate the cores using the metal structure at saturation light intensity if possible (300 mol per meter squared per second at 0.5m depth) for about 3h.9. Before taking DO measurement, move the DO probe up and down three times to ensure no DO gradient (but do not disturb sediment), and then measure percentDO, DO, and temperature in each core.Light controlsOnce a month (June, July, August), on a sunny day, incubate 10 cores for 3h with different light intensities to determine primary productivity under different light intensities and different temperatures. It would be best to do this the day after routine sampling (i.e., when retrieving the benthic sampler) so that the results can be compared to those from the routine sampling. Different light levels are obtained using white mesh bags around the core tubes.Core 1 and 6, lightCore 2 and 7, 2xCore 3 and 8, 4xCore 4 and 9, 8xCore 5 and 10, darkIMPORTANT: After the incubations, measure light intensity inside a core tube covered for the different treatments. This is done by removing the light meter from the metal holder and placing it facing up in a core using zip ties and a blue stopper at the bottom. Then place treatment bags over the top and measure light when holding the core at the level they reach in the incubator; use the marking on the light meter cord to make sure this is standardized for all measurements. This should be done 8 times total (each bag plus twice without bags).Light saturationOnce a month in the summer of 2013, we conducted sediment core incubations with varying amounts of shade cloth applied to the cores. Sediment cores received 0, 2, 4, 8, or 15 layers of shade cloth, with two cores in each treatment. All cores were then incubated in the lake over the same 3hr period at a depth of 0.5m.Sediment Dry Weight and Weight on Combustion1. Remove 0.75cm of sediment from a core into a plastic deli container. This should be done on a fresh core. This is the same sample that is used for chl analysis.2. Subsample 5 to 10mL sediment solution and place in a pre-weighed tin tray in oven at 60C for at least 12 hours. When dry, weigh for dry weight.In 2014, the method for sampling benthic chlorophyll changed. Sediment Dry Weight measurements were taken from these samples as well. Below is the pertinent section from the methods protocols. Processing after the collection of the sample was not changed.Take sediment samples from the 5 cores collected for sediment characteristics. Take 4 syringes of sediment with 10mL syringe (15.3 mm diameter). Take 4-5cm of sediment. Then, remove bottom 2cm and place top 2cm in the film canister.3. Combust at 550C for 4.5 hours. Weigh tray.4. If not analyzing combusted samples immediately, place in drying oven before weighing.
Version Number
15

Lake Wingra Exclosure Experiment at North Temperate Lakes LTER: Sampledate Conditions 2005 - 2008

Abstract
Starting in late summer 2005, Wisconsin Dept of Natural Resources (WDNR), Dane County, Friends of Lake Wingra (FOLW), and NTL-LTER initiated a 3-year experiment in Lake Wingra to test the response of the native macrophyte community to clearer water produced from a major carp reduction program. This demonstration-scale experiment includes the construction of a 1.0-hectare rectangular carp exclosure with its solid vinyl walls extending from the lake shoreline to a water depth of 2.9 meters. NTL-LTER conducts the routine limnological monitoring of the lake and exclosure and is leading the science evaluation of potential lake restoration activities. The exclosure experiment was terminated in the fall of 2008. The exclosure was removed from Lake Wingra at that time. Sampling is done both within the exclosure and at a control site located nearby in the littoral zone. The sample location within the exclosure is equidistant from the side walls and approximately 75 meters from the shore in a water depth of approximately 2.5 meters. The control site sample location is approximately 75 meters west of the exclosure sample site at the same approximate distance from shore and water depth. Samples are taken at the same time and on the same schedule as the NTL-LTER limnological sampling on Lake Wingra, e.g., biweekly spring through summer, every 4 weeks in the fall, and once during the winter depending on ice conditions. Parameters measured within the exclosure and at the control site include water temperature, dissolved oxygen, secchi depth and chlorophyll-a. Additional parameters measured only within the exclosure include total Kjeldahl nitrogen, nitrate + nitrite nitrogen, ammonia nitrogen, total phosphorus, dissolved reactive phosphorus and dissolved reactive silica. Auxiliary data collected while sampling for the exclosure experiment. Data include time of day, air temperature, cloud cover, wave height, bottom depth, wind speed and direction. Sampling Frequency: generally bi-weekly during ice-free season from late March or early April through early September, then every 4 weeks through late November. Number of sites: 2
Dataset ID
244
Date Range
-
Maintenance
completed
Metadata Provider
Methods
Measuring Air Temperature, Wind Speed, Wind Direction, percent Cloud Cover, and Wave Height1. Estimate air temperature and check forecast before and after going into the field.2. Estimate the wind speed. Record a range if the wind is variable (e.g. 10-15 mph).3. Face the direction that the wind is coming from. Use lake maps to determine which direction the wind is flowing.4. Estimate and record the percent cloud cover.5. Estimate and record the wave height in cm (record the vertical distance from wave crest to the wave trough).
Short Name
FOLWEXSMP
Version Number
18
Subscribe to sample conditons