Little Rock Lake Experiment at North Temperate Lakes LTER: Nutrients 1996 - 2000

Abstract
The Little Rock Acidification Experiment was a joint project involving the USEPA (Duluth Lab), University of Minnesota-Twin Cities, University of Wisconsin-Superior, University of Wisconsin-Madison, and the Wisconsin Department of Natural Resources. Little Rock Lake is a bi-lobed lake in Vilas County, Wisconsin, USA. In 1983 the lake was divided in half by an impermeable curtain and from 1984-1989 the northern basin of the lake was acidified with sulfuric acid in three two-year stages. The target pHs for 1984-5, 1986-7, and 1988-9 were 5.7, 5.2, and 4.7, respectively. Starting in 1990 the lake was allowed to recover naturally with the curtain still in place. Data were collected through 2000. The main objective was to understand the population, community, and ecosystem responses to whole-lake acidification. Funding for this project was provided by the USEPA and NSF. Parameters characterizing the nutrient chemistry of the treatment and reference basins of Little Rock Lake are measured at one station in the deepest part of each basin at the top and bottom of the epilimnion, mid-thermocline, and top, middle, and bottom of the hypolimnion. These parameters include total nitrogen, total dissolved nitrogen, nitrate, ammonia, total phosphorus, total dissolved phosphorus, dissolved reactive phosphorus, bicarbonite-reactive filtered and unfiltered silica, dissolved reactive silica, total inorganic carbon, dissolved inorganic carbon, total organic carbon, dissolved organic carbon, and total particulate matter. Sampling Frequency: varies - Number of sites: 2
Dataset ID
246
Date Range
-
Maintenance
completed
Metadata Provider
Methods
Inorganic and organic carbonSamples for inorganic and organic carbon are collected together with a peristaltic pump and tubing and in-line filtered, if necessary, (through a 0.40 micron polycarbonate filter) into glass, 24 ml vials (that are compatible with the carbon analyzer autosampler), and capped with septa, leaving no head space. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 2-3 weeks.The detection limit for inorganic carbon is 0.15 ppm, and the analytical range for the method is 60 ppm.The detection limit for organic carbon is 0.30 ppm and the analytical range for the method is 30 ppm.Method Log: Prior to May 2006 samples, inorganic carbon was analyzed by phosphoric acid addition on an OI Model 700 Carbon Analyzer. From May 2006 to present, inorganic carbon is still analyzed by phosphoric acid addition, but on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer.Method Log: Prior to May 2006 samples, organic carbon was analyzed by heated persulfate digestion on an OI Model 700 Carbon Analyzer. From May 2006 to present, Organic carbon is analyzed by combustion, on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer.Dissolved reactive siliconSamples for silicon are collected with a peristaltic pump and tubing and in-line filtered (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 ml of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius.Dissolved reactive silica is determined by the Heteropoly Blue Method and the absorption is measured at 820 nm.The detection limit for silicon is 6 ppb and the analytical range is 15000 ppb.Method Log These determinations were performed manually using a Bausch and Lomb Spectrophotometer from the beginning of the project until April 1984. From 1984 through 2005, dissolved reactive silicon was determined on a Technicon Auto Analyzer II. From January 2006 to present, samples are run on an Astoria-Pacific Astoria II Autoanalyzer.total and dissolved nitrogen and phosphorusSamples for total and dissolved nitrogen and phosphorus analysis are collected together with a peristaltic pump and tubing and in-line filtered, when necessary, (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 mL of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius.The samples must first be prepared for analysis by adding an NaOH–Persulfate digestion reagent and heated for an hour at 120 degrees C and 18-20 psi in an autoclave.The samples are analyzed for total nitrogen and total phosphorus simultaneously by automated colorimetric spectrophotometry, using a segmented flow autoanalyzer. Total nitrogen is determined by utilizing the automated cadmium reduction method, as described in Standard Methods, where the absorption is monitored at 520 nm.The detection limit for total and dissolved nitrogen is approximately 21 ppb and the analytical range for the method extends to 2500 ppb.The detection limit for total phosphorus is approximately 3 ppb and the analytical range for the method extends to 800 ppb.Method Log: Prior to January 2006 samples, total nitrogen was determined on a Technicon segmented flow autoanalyzer. From 2006 to present, total nitrogen is determined by an Astoria-Pacific Astoria II segmented flow autoanalyzer.
Short Name
LRNUTR1
Version Number
4

Cascade Project at North Temperate Lakes LTER: Nutrients 1991 - 2007

Abstract
Physical and chemical variables are measured at one central station near the deepest point of each lake. In most cases these measurements are made in the morning (0800 to 0900). Vertical profiles are taken at varied depth intervals. Chemical measurements are sometimes made in a pooled mixed layer sample (PML); sometimes in the epilimnion, metalimnion, and hypolimnion; and sometimes in vertical profiles. In the latter case, depths for sampling usually correspond to the surface plus depths of 50percent, 25percent, 10percent, 5percent and 1percent of surface irradiance.The 1991-1999 chemistry data obtained from the Lachat auto-analyzer. Like the process data, there are up to seven samples per sampling date due to Van Dorn collections across a depth interval according to percent irradiance. Voichick and LeBouton (1994) describe the autoanalyzer procedures in detail.Nutrient samples were sent to the Cary Institute of Ecosystem Studies for analysis beginning in 2000. The Kjeldahl method for measuring nitrogen is not used at IES, and so measurements reported from 2000 onwards are Total Nitrogen.
Core Areas
Dataset ID
78
Date Range
-
LTER Keywords
Maintenance
completed
Metadata Provider
Methods
Methods for 1984-1990 were described by Carpenter and Kitchell (1993) and methods for 1991-1997 were described by Carpenter et al. (2001).Carpenter, S.R. and J.F. Kitchell (eds.). 1993. The Trophic Cascade in Lakes. Cambridge University Press, Cambridge, England.Carpenter, S.R., J.J. Cole, J.R. Hodgson, J.F. Kitchell, M.L. Pace,D. Bade, K.L. Cottingham, T.E. Essington, J.N. Houser and D.E. Schindler. 2001. Trophic cascades, nutrients and lake productivity: whole-lake experiments. Ecological Monographs 71: 163-186.Additional methods are described in the Cascade Methods manual, which can be found here:http://c13.valuemembers.net/Pages/methods_09.html
Short Name
CPHYS3
Version Number
4