US Long-Term Ecological Research Network

Modeled Organic Carbon, Dissolved Oxygen, and Secchi for six Wisconsin Lakes, 1995-2014

Abstract
This data package contains model output data, driving data, and supplemental information for a two-layer modeling study that investigated organic carbon and oxygen dynamics within six Wisconsin lakes over a twenty-year period (1995-2014). The six lakes are Lake Mendota, Lake Monona, Trout Lake, Allequash Lake, Big Muskellunge Lake, and Sparkling Lake. The model output includes daily predictions of six state variables: labile particulate organic carbon, recalcitrant particulate organic carbon, labile dissolved organic carbon, recalcitrant dissolved organic carbon, dissolved oxygen, and Secchi depth. The output also includes daily predictions of physical and metabolism fluxes that were used in the prediction of the state variables. This data package also contains model driving data for each lake and other supplemental information that was calculated during the modeling runs.<br/>
Core Areas
Creator
Dataset ID
421
Date Range
-
Methods
Data included in this package include output, driving data, and supplemental calculated information for a modeling study.<br/>
NTL Themes
Version Number
1

LAGOS-NE v.1.054.1 - Lake water quality time series and geophysical data from a 17-state region of the United States

Abstract
Time series of mean summer total nitrogen (TN), total phosphorus (TP), stoichiometry (TN:TP) and chlorophyll values from 2913 unique lakes in the Midwest and Northeast United States. Epilimnetic nutrient and chlorophyll observations were derived from the Lake Multi-Scaled Geospatial and Temporal Database LAGOS-NELIMNO version 1.054.1, and come from 54 disparate data sources. These data were used to assess long-term monotonic changes in water quality from 1990-2013, and the potential drivers of those trends (Oliver et al., submitted). Summer was used to approximate the stratified period, which was defined as June 15 to September 15. The median number of observations per summer for a given lake was 2, but ranged from 1 to 83. The rules for inclusion in the database were that, for a given water quality parameter, a lake must have an observation in each period of 1990-2000 and 2001-2011. Additionally, observations must span at least 5 years. Each unique lake with nutrient or chlorophyll data also has supporting geophysical data, including climate, atmospheric deposition, land use, hydrology, and topography derived at the lake watershed (variable prefix iws) and HUC 4 (variable prefix hu4) scale. Lake-specific characteristics, such as depth and area, are also reported. The geospatial data came from LAGOS-NEGEO version 1.03. For more specific information on how LAGOS-NE was created, see Soranno et al. (2015).
Soranno P.A., Bissell E.G., Cheruvelil K.S., Christel S.T., Collins S.M., Fergus C.E., Filstrup C.T., Lapierre J.-F., Lottig N.R., Oliver S.K., Scott C.E., Smith N.J., Stopyak S., Yuan S., Bremigan M.T., Downing J.A., Gries C., Henry E.N., Skaff N.K., Stanley E.H., Stow C.A., Tan P.-N., Wagner T., and Webster K.E. 2015. Building a multi-scaled geospatial temporal ecology database from disparate data sources: fostering open science and data reuse. Gigascience 4: 28. doi: 10.1186/s13742-015-0067-4.
Dataset ID
333
Date Range
-
Methods
See Oliver et al. (submitted) and Soranno et al. (2015) for details on sources of data, methods of collection, and derivation of parameters
Oliver S.K., Collins S.M., Soranno P.A., Wagner T., Stanley E.H., Jones J.R., Stow C.A., Lottig N.R. Unexpected stasis in a changing world: Lake nutrient and chlorophyll trends since 1990. Submitted to Global Change Biology.
Soranno P.A., Bissell E.G., Cheruvelil K.S., Christel S.T., Collins S.M., Fergus C.E., Filstrup C.T., Lapierre J.-F., Lottig N.R., Oliver S.K., Scott C.E., Smith N.J., Stopyak S., Yuan S., Bremigan M.T., Downing J.A., Gries C., Henry E.N., Skaff N.K., Stanley E.H., Stow C.A., Tan P.-N., Wagner T., and Webster K.E. 2015. Building a multi-scaled geospatial temporal ecology database from disparate data sources: fostering open science and data reuse. Gigascience 4: 28. doi: 10.1186/s13742-015-0067-4 .
NTL Themes
Version Number
15

LAGOS - Lake nitrogen, phosphorus, and stoichiometry data and geospatial data for lakes in a 17-state region of the U.S.

Abstract
This dataset includes information about total nitrogen (TN) concentrations, total phosphorus (TP) concentrations, TN:TP stoichiometry, and 12 driver variables that might predict nutrient concentrations and ratios. All observed values came from LAGOSLIMNO v. 1.054.1 and LAGOSGEO v. 1.03 (LAke multi-scaled GeOSpatial and temporal database), an integrated database of lake ecosystems (Soranno et al. 2015). LAGOS contains a complete census of lakes great than or equal to 4 ha with corresponding geospatial information for a 17-state region of the U.S., and a subset of the lakes has observational data on morphometry and chemistry. Approximately 54 different sources of data were compiled for this dataset and were mostly generated by government agencies (state, federal, tribal) and universities. Here, we compiled chemistry data from lakes with concurrent observations of TN and TP from the summer stratified season (June 15-September 15) in the most recent 10 years of data included in LAGOSLIMNO v. 1.054.1 (2002-2011). We report the median TN, TP and molar TN:TP values for each lake, which was calculated as the grand median of each yearly median value. We also include data for lake and landscape characteristics that might be important controls on lake nutrients, including: land use (agricultural, pasture, row crop, urban, forest), nitrogen deposition, temperature, precipitation, hydrology (baseflow), maximum depth, and the ratio of lake area to watershed area, which is used to approximate residence time. These data were used to identify drivers of lake nutrient stoichiometry at sub-continental and regional scales (Collins et al, submitted). This research was supported by the NSF Macrosystems Biology program (awards EF-1065786 and EF-1065818) and by the NSF Postdoctoral Research Fellowship in Biology (DBI-1401954).
Dataset ID
332
Methods
See Soranno, P.A., Bissell, E.G., Cheruvelil, K.S., Christel, S.T., Collins, S.M., Fergus, C.E., Filstrup, C.T., Lapierre, J.F., Lottig, N.R., Oliver, S.K., Scott, C.E., Smith, N.J., Stopyak, S., Yuan, S., Bremigan, M.T., Downing, J.A., Gries, C., Henry, E.N., Skaff, N.K., Stanley, E.H., Stow, C.A., Tan, P.-N., Wagner, T., and Webster, K.E. 2015. Building a multi-scaled geospatial temporal ecology database from disparate data sources: fostering open science and data reuse. Gigascience 4: 28. doi: 10.1186/s13742-015-0067-4 for details on how the observed values were obtained.
See Collins et al. Lake nutrient stoichiometry is less predictable than nutrient concentrations at regional and sub-continental scales, Submitted to Ecological Applications, for details on data filtering and relationships between nutrient chemistry and landscape characteristics
Version Number
12

Satellite derived secchi disk depth and other lake and landscape characteristics in Wisconsin, USA, 1991 - 2012

Abstract
This data supports the following publication: Rose, K.C., S.R. Greb, M. Diebel, and M.G. Turner. Annual precipitation as a regulator of spatial and temporal drivers of lake water clarity. Ecological Applications. The data uses satellite remotely sensed estimates of Secchi disk depth (Landsat imagery), landscape features, and lake characteristics to understand how and why lakes vary and respond to different drivers through time and space. The data were produced by the authors and their collaborators, as acknowledged in the manuscript. The Secchi disk depth data span the time period 1991-2012.
Contact
Dataset ID
331
Date Range
-
Methods
The complete methods for this manuscript are described in the manuscript: Rose, K.C., S.R. Greb, M. Diebel, and M.G. Turner. Annual precipitation as a regulator of spatial and temporal drivers of lake water clarity. Ecological Applications.
NTL Keyword
Version Number
16

River Nutrient Uptake and Transport at North Temperate Lakes LTER (2005-2011)

Abstract
These data were collected by Stephen Michael Powers and collaborators for his Ph.d. research, documented in his dissertation: River Nutrient Uptake and Transport Across Extremes in Channel Form and Drainage Characteristics. A major goal of this research was to better understand how ecosystem form and landscape setting dictate aquatic biogeochemical functioning and elemental transport through rivers. To achieve this goal, major and minor ions were measured in both northern and southern Wisconsin streams located in a variety of land use settings. In total, 27 different streams were sampled at 104 different stations (multiple stations per system) from both groundwater and surface water sources. Organic and inorganic carbon and nitrogen pools were also measured in northern and southern Wisconsin streams. The streams that were sampled in northern Wisconsin flow through wetland ecosystems. In sampling such streams, the goal was to better understand how wetland ecosystems influence river nutrient deliveries. There is a large amount of stream chemistry data for Big Spring Creek, WI; where the influence of a small reservoir on solute transportation and transformation was studied in an agricultural watershed. All stream chemistry data is incorporated in a single data file, Water Chemistry 2005-2011. While the data is not included in the dissertation, a sediment core study was also done in the small reservoir and channel of Big Spring (BS) Creek, WI. The results of this study are featured in three data tables: BS Creek Sediment Core Analysis, BS Creek Sediment Core Chemistry, and BS Creek Longitudinal Profile. Finally, two data tables list the geospatial information of sampling sites for stream chemistry and sediment coring in Big Spring Creek. Documentation: Powers, S.M., 2012. River nutrient uptake and transport across extremes in channel form and drainage characteristics. ProQuest Dissertations and Theses. The University of Wisconsin - Madison, United States -- Wisconsin, p. 140.
Dataset ID
281
Date Range
-
Metadata Provider
Methods
I. Stream chemistry sample collection methods: core-sediment core was taken from the benthic zone of the streamgeopump-geopump used to pump stream water into collection bottlegrab-collection bottle filled with stream water by hand and filtered in the fieldgrabfilter- stream water collected by hand and filtered in field. Unfiltered and filtered samples placed in separate collection bottles.isco- sample collected by use of an ISCO automated samplerpoint- sampled collected by method outlined in patent US8337121sedimentgrab- sediment sample taken in field by hand and placed in collection bottlesyringe- sample collected from stream by syringe and placed in collection bottlesyringe_filter- sample collected from stream by syringe filter. Unfiltered and filtered samples placed in separate collection bottles. II. Stream chemistry analytical methods: All water samples were kept on ice and in the dark following collection, then were either acidified (TN/TP, TDN/TDP) or frozen until analysis (all other analytes).no32_2- This is NO<sub>3-</sub>N which is operationally defined as nitrate nitrogen + nitrite nitrogen. Determined by flow injection analysis on Astoria Pacific Instruments Autoanalyzer (APIA).nh4_n, tn1, tp1, tdn, tdp- All analytes measured by flow injection analysis on Astoria Pacific Instruments Autoanalyzer (APIA).srp- measured colorometrically using the molybdate blue method [APHA 1995] and a Beckman spectrophotometer.doc- measured using a Shimadzu carbon analyzer.doc_qual- the goal in doing this analysis is to determine the source of dissolved organic carbon (doc) measured in a particular riverine ecosystem. This was achieved by UV absorbance which provides an estimate of the aromaticity of the doc in a sample, and by extension, the potential source of the doc.cl, no2, no3, br, and so4- all measured by ion chromatography. See http://www.nemi.gov; method number 4110C. Detection limits for method number 4110C: cl-20&micro;g/l, no2-15&micro;g/l, no3-17&micro;g/l, br-75&micro;g/l, and so4-75&micro;g/l.ysi_cond, do, ph_field, wtemp- all measured by use of a standard YSI meter.tss- measured by standard methods. A thoroughly mixed sample is filtered and dried at 103-105 degreesCelcius. The obtained residue represents the amount of solids suspended in the sample solution. See http://www.nemi.giv; method number D5907.tot_om- measured by standard methods. The residue obtained from the tss procedure is ignited at 550 degreesCelcius and weighed, the difference in weight representing total volatile solids. Total volatile solids represents the portion of the residue that is composed of organic molecules. See http://www.nemi.gov; method number 160.4.turbid- measured by use of a nephelometer. III. Big Spring Sediment Coring Methods A. Field Methods- collecting sediment coresSediment core samples taken with WDNR piston core samplerB. Sediment Analysis- HydrometerDocumentation: Robertson, G.P., Coleman, D.C., Bledsoe, C.S. and Sollins, P., 1999. Standard Soil Methods for Long-Term Ecological Research. Oxford University Press, New York, 462 pp.Hydrometer Analysis- procedure used to determine percent clay:<p style="margin-left:.25in;">1. Dry the sample in a pre-weighed aluminum pan for at least 24 hr at 105 C. Make sure sample is completely dry before weighing.<p style="margin-left:.25in;">2. Weigh the dried sample, then ash for at least 8 hr at 550 C. Make sure to break up any large clumps before ashing.<p style="margin-left:.25in;">3. Weigh the ashed sample, then crush any aggregates with a pestal. Mix sample thoroughly.<p style="margin-left:.25in;">4. Transfer 40g, plus or minus one gram, of the sample into a 500mL wide mouth bottle<p style="margin-left:.25in;">5. Add 10g of sodium hexametaphosphate to the bottle.<p style="margin-left:.25in;">6. Add approx 200mL of deionized water to bottle. Shake vigorously with hand.<p style="margin-left:.25in;">7. Stir samples on shaker table for at least 8 hr at speed 40. Putting them in a box and fastening with bungee cords works best.<p style="margin-left:.25in;">8. Transfer sample to 1L cylinder, making sure to get all of sample out of bottle. Fill cylinder with deionized water up to the 1L mark.<p style="margin-left:.25in;">9. Prepare a blank cylinder by adding 10g of sodium hexametaphosphate and filling to 1L.<p style="margin-left:.25in;">10. Allow all cylinders to equilibrate to room temperature ( approx 30 min).<p style="margin-left:.25in;">11. Starting with the blank cylinder, put stopper into cylinder and shake end-over-end for approx 5 min. Rinse stopper. Repeat this step for all cylinders, rinsing stopper between cylinders.<p style="margin-left:.25in;">12. Record the time that you stopped shaking each cylinder.<p style="margin-left:.25in;">13. At 1.5 hr from time of shaking, record temperature and hydrometer level of the blank cylinder. Then record the 1.5 hr hydrometer level for each successive cylinder.<p style="margin-left:.25in;">14. At 24 hr from time of shaking, record temperature and hydrometer level of the blank cylinder. Then record the 24 hr hydrometer level for each successive cylinder. Sieve Analysis- procedure used to determine quantity of sand and silt<p style="margin-left:.25in;">1. After hydrometer analysis, pour the entire sample into the .063mm sieve. Rinse the sample thoroughly until all the clay is out. Try to break up any clay clumps you see.<p style="margin-left:.25in;">2. Transfer the sample to a pre-weighed and labeled aluminum pan. You will probably need to backwash the sieve to get the entire sample out. You can use a syringe to pull water from the pan if it gets too full. Dry the sample for 48 hours at 50-60C.<p style="margin-left:.25in;">3. Before transferring the dried sample to the sieves, make sure you pre-weigh the sieves and put their weight on the data sheet. You will need to do this before every sample as you might not get all the sample out of the sieves from the previous sample. Stack the sieves in the following order, top to bottom : 4mm, 2mm, 1mm, 0.5mm, 0.25mm, 0.125mm, 0.063mm, and pan. Pour the sample into the top sieve. Place the lid on, located on sieve shaker, and put the stack of sieves into the sieve shaker. Fasten the tie downs. Set shaker for 3 minutes. <p style="margin-left:.25in;">4. Remove stack of sieves from shaker. It&rsquo;s ok to leave the pan behind temporarily as it might be tight. Weigh each sieve and record the weight in the data sheet. If you see any clay clumps, break them up with your fingers and re-shake the stack a little, using hands is okay.<p style="margin-left:.25in;">5. Dump the sample out in the trash and clean the sieve with the brush. At the end of the day it might be necessary to backwash the sieves with water and dry overnight in the oven. <p style="margin-left:.25in;"> Calculations:1. percent clay was determined by the hydrometer analysis- P1.5, P24, X1.5, X24, and m are the variables that were calculated to determine percent clay by the hydrometer analysis.P1.5= ((sample hydrometer reading at 1.5 hours- blank hydrometer reading at 1.5 hours)/ (sample weight)) multiplied by 100.P24= ((sample hydrometer reading at 24 hours- blank hydrometer reading at 24 hours)/ (sample weight)) multiplied by 100X1.5= 1000*(.00019*(-.164* (sample hydrometer reading at 1.5 hours)+16.3)<sup>2</sup> *8100X24=1000*(.00019*(-.164* (sample hydrometer reading at 24 hours)+16.3)<sup>2</sup> *8100m= (P1.5-P24)/(ln(X1.5/X24))percent clay = m * ln(2/X24)) + P24clay (grams) = total weight * ( percent clay/ 100)2. percent Sand and percent Silt were determined based on the results of the sieve analysis which determined the grams of sand and silt.percent sand= total weight * (percent sand/ 100)percent silt= total weight * (percent silt/ 100)3. Othersorganic matter (grams) was calculated in this analysis as dry weight (grams) &ndash; ashed weight (grams)percwnt organic matter was calculated as ((organic matter (grams))/(total dry weight (grams)) multiplied by 100 C. Sediment Chemical Analysis1. SRP/ NaOH-PChemical analysis was done according to the protocol outlined in Pionke and Kunishi (1992). Each sample was first centrifuged and separated into aqueous and sediment fractions. The sediment fraction was then dried. The aqueous fraction was analyzed for soluble reactive phosphorus (srp) by automated colorimetry Nemi Method Number 365.4; see http://www.nemi.gov. NaOH P was then determined by NaOH extractions as described in Pionke and Kunishi (1992). Documentation: Pionke HB, Kunishi HM (1992) Phosphorus status and content of suspended sediment in a Pennsylvania watershed. Soil Sci 153:452&ndash;462.2. NH4 / KCl-NH4 The exact procedure that was used to analyze samples for ammonium is unknown. However, it is known that a KCl extraction was used. The KCl-NH4 was calculated as the concentration of ammonium in milliGramsPerLiter divided by the sediment weight in grams. 3. NO3 / KCl-NO3The exact procedure that was used to analyze samples for nitrate is also unknown. Again, it is known that a KCL extraction was used. The KCl-NO3 was calculated as the concentration of nitrate in milliGramsPerLiter divided by the sediment weight in grams.Note: The same sediment sample was used to measure ammonium and nitrate IV. Big Spring Creek Longitudinal Profile A standard longitudinal stream profile was conducted at Big Spring Creek, WI (wbic=176400) on unknown date(s). It is speculated that the profile was done during the summer of 2005, during which the rest of the data for Big Spring Creek was collected. Measurements for the profile began at the Big Spring Dam site (43.67035,-89.64225), a dam which was subsequently removed. The first (x_dist, y_dist) of (2.296, 5.57) corresponds to the location where the stream crosses Golden Court Road, whereas the second coordinate pair of (-2.615, -36.303) corresponds to the point below the previous Big Spring Creek Dam site. The third (x_dist, y_dist) of (-9.472, 7.681) corresponds to the top of the dam gates and is assigned a distance=0 as it is the starting point.
Version Number
23

WDNR Yahara Lakes Fisheries: Fish Lengths and Weights 1987-1998

Abstract
These data were collected by the Wisconsin Department of Natural Resources (WDNR) from 1987-1998. Most of these data (1987-1993) precede 1995, the year that the University of Wisconsin NTL-LTER program took over sampling of the Yahara Lakes. However, WDNR data collected from 1997-1998 (unrelated to LTER sampling) is also included. In 1987 a joint project by the WDNR and the University of Wisconsin-Madison, Center for Limnology (CFL) was initiated on Lake Mendota. The project involved biomanipulation of fish communities within the lake, which was acheived by stocking game fish species (northern pike and walleye). The goal was to induce a trophic cascade that would improve the water clarity of Lake Mendota. See Lathrop et al. 2002. Stocking piscivores to improve fishing and water clarity: a synthesis of the Lake Mendota biomanipulation project. Freshwater Biology 47, 2410-2424. In collecting these data, the objective was to gather population data and monitor populations to track the progress of the biomanipulation. The data is dominated by an assesssment of the game fishery in Lake Mendota, however other Yahara Lakes and non-game fish species are also represented. A combination of gear types was used to gather the population data including boom shocking, fyke netting, mini-fyke netting, seining, and gill netting. Not every sampling year includes length and weight data from all gear types. The WDNR also carried out randomized, access-point creel surveys to estimate fishing pressure, catch rates, harvest, and exploitation rates. Five data files each include length-weight data, and are organized by the type of gear or method which was used to collect the data: 1) fyke, mini-fyke, and seine netting 2) boom shocking 3) gill netting (1993 only) 4)walleye age as determined by scale and spine analysis (1987 only), and 5) creel survey. The final data file contains creel survey information: number of anglers fishing the shoreline, and number of anglers that started and completed trips from public and private access points.
Core Areas
Dataset ID
279
Date Range
-
Metadata Provider
Methods
BOOM SHOCKING1987:A standard WDNR electrofishing boat was used on Lake Mendota set at 300 volts and 2.5 amps (mean) DC, with a 20 % duty cycle and 60 pulses per second. On all sampling dates two people netted fish, the total electrofishing crew was three people. Shocking was divided into stations. For each station, the actual starting and ending time was recorded. Starting and ending points of each station were plotted on a nap. A 7.5 minute topographic map (published 1983) and a cartometer was used to develop a standardized shoreline mileage numbering scheme. Starting at the Yahara River outlet at Tenney Park and measuring counterclockwise, the shoreline was numbered according to the number of miles from the outlet. The length of shoreline shocked for each station was determined using the same maps. The objectives of the fall 1987 electrofishing was: to gather CPE data for comparison with previous surveys of the lake; develop a database for relating fall electroshocker CPE to predator density; collect fall predator diet data; make mark-recapture population estimates of YOY predators; and determine year-class-strength of some nonpredators (yellow perch, yellow bass, and white bass).1993: Electrofishing was used to continue marking largemouth and smallmouth bass (because of low CPE in fyke nets), to recapture fish marked in fyke netting, and to mark and recapture walleyes ( less than 11.0 in.) on Lake Mendota. Four person crews electrofished after sunset from May 05 to June 03, 1993. A standard WDNR electrofishing boat was used, set at about 300 volts and 15.0 amps (mean) DC, with a 20 % duty cycle at 60 pulses per second. On all sampling dates two people netted fish; thus, CPE data are given as catch per two netter hour or mile. Shocking was divided into stations. For each station the actual starting and ending time and the generator s meter times was recorded. Starting and ending points of each station were plotted on a map. 7.5 minute topographic maps (published in 1983) were used in addition to a cartometer to develop a standardized shoreline mileage numbering scheme. Starting at the Yahara River outlet at Tenney Park and measuring counterclockwise the shoreline was numbered according to the number of miles from the outlet. The length of shoreline shocked for each station was determined using these maps. The 4 person electroshocker crews were used again from September 20 to October 19. Fall shocking had several objectives: to gather CPE data for comparison with previous surveys of the lake; develop a database for relating fall electroshocker CPE to piscivore density; and make mark recapture population estimates of young of year (YOY) piscivores.1997:5/13/1997-5/20/1997: Electrofishing was completed at night on lakes: Mendota, Monona, and Waubesa. A standard WDNR electrofishing boat was used, set from 320-420 volts and 16-22 amps DC, with a 20 % duty cycle at 50 pulses per second. Two netters were used for each shocking event. At a particular station, starting and ending times where shocking took place were recorded. The location of the designated shocking stations is unknown.9/23/1997-10/14/1997: Electrofishing was completed at night on Mendota, Monona, Waubesa, and Wingra. A standard WDNR electrofishing boat was used, set from 315-400 volts and 16-24 amps DC, with a 20% duty cycle at 60 pulses per second. Two netters were used for each shocking event. Starting and ending time at each shocking station was listed. The location of the designated shocking stations is unknown.1998:Electrofishing was completed at night on Mendota, Monona, Wingra, and Waubesa from 5/12/1998- 10/28/1998. A standard WDNR electrofishing boat was used, set from 240-410 volts and 15-22 amps DC, with a 20% duty cycle at 50-100 pulses per second. Two netters were used for each shocking event. Starting and ending time at each shocking station was listed. The location of the designated shocking stations is unknown. FYKE NETTING1987:Fyke nets were fished daily from March 17 to April 24, 1987 on Lake Mendota. The nets were constructed of 1.25 inch (stretch) mesh with a lead length of 50 ft. (a few 25 ft. leads were used). The hoop diameter was 3 ft. and the frame measured 3 ft. by 6 ft. Total length of the net was 28 ft. plus the lead length. Nets were set in 48 unknown locations. Initially, effort was concentrated around traditional northern pike spawning sites (Cherokee Marsh, Sixmile Creek, Pheasant Branch Creek, and University Bay). As northern pike catch-per-effort (CPE) declined some nets were moved onto rocky shorelines of the lake to capture walleyes. All adult predators (northern pike, hybrid muskie, largemouth and smallmouth bass, walleye, gar, bowfin, and channel catfish) captured were tagged and scale sampled. Measurements on non-predator species captured in fyke nets were made one day per week. This sampling was used to index size structure and abundance, and to collect age and growth data. In each net, total length and weight of 20 fish of each species caught was measured, and the remaining caught were counted.1993:Same methods as 1987, except fyke nets were fished from 4/8/1993-4/29/1993 on Lake Mendota. The 1993 fyke net data also specifies the &ldquo;mile&rdquo; at which the fyke net was set. This is defined as the number of miles from the outlet of the Yahara River at Tenney Park, moving counterclockwise around the lake. In addition, abundance and lengths of non-gamefish species captured in fyke nets were recorded one day per week. Six nets were randomly selected to sample for non-gamefish data. This sampling was used to index size structure and abundance, and to collect age and growth data. In each randomly selected net, total length and weight was measured for 20 fish of each species, and the remaining caught were counted.1998:There is no formal documentation for the exact methods used for fyke netting from 3/3/1998-8/12/1998 on Lake Mendota. However, given that the data is similar to data collected in 1987 and 1993 it is speculated that the same methods were used.MINI-FYKE NETTING1989:There is no formal documentation for the exact methods used for mini-fyke netting on Lake Mendota and Lake Monona from 7/26/1989-8/25/1989. However, given that the data is similar to data collected from 1990-1993 it is speculated that the same methods were used. In the sampling year of 1989, mini-fyke nets were placed at 22 different unknown stations.1990-1993: Mini-fyke nets were fished on Lake Mendota and Lake Monona during July-September at 20, 29, 13, and 15 sites per month during 1990, 1991, 1992, and 1993, respectively to estimate year-class strength, relative abundance, and size structure of fishes in the littoral zone. Nets were constructed with 3/16 in. mesh, 2 ft. diameter hoops, 2 ft. x 3 ft. frame, and a 25 ft. lead. Sites were comparable to seine sites used in previous surveys. Sites included a variety of substrate types and macrophyte densities. To exclude turtles and large piscivores from minifyke nets, some nets were constructed with approximately 2 in. by 2 in. mesh at the entrance to the net. Thus, mini-fyke net data are most accurate for YOY fishes, and should not be used to make inferences about fishes larger than the exclusion mesh size. 1997:There is no formal documentation for the mini-fyke methods which were used on Lake Waubesa and Lake Wingra from 9/16/1997-9/18/1997. However, given that the data is similar to data collected in 1989, and 1990-1993, it is speculated that the methods used during 1997 are the same. SEINE NETTING1989, 1993: Monthly shoreline seining surveys were conducted on Lake Mendota and Lake Monona during June through September to estimate year class-strength, relative abundance, and size structure of the littoral zone fish community. Twenty sites were identified based on previous studies. Sites included a variety of substrate types and macrophyte densities. Seine hauls were made with a 25ft bag seine with 1/8 inch mesh pulled perpendicular to shore starting from a depth of 1 m. Twenty fish of each species were measured from each haul and any additional fish were counted. Gill Netting (1993)Experimental gill nets were fished in weekly periods during June through August, 1993. Gill nets were used to capture piscivores for population estimates of fish marked in fyke nets. All nets were constructed of five 2.5-4.5 in. mesh panels, and were 125 ft. long. Nets set in water shallower than 10 ft. were 3ft. high or less; all others were 6ft. high or less. Sampling locations were selected randomly from up to three strata: 1) offshore reef sets, 2) inshore sets, 6.0-9.9 ft. deep, and 3) mid-depth sets, 10-29.9 ft. deep. The exact location at which the gill nets were set on the lake is unknown because the latitude and longitude values which were recorded by the WDNR are invalid. Temperature and dissolved oxygen profiles were used to monitor the development of the thermocline and guide net placement during July and August. After the thermocline was established nets were set out to the 30 ft. contour or to the maximum depth with dissolved oxygen greater than 2 ppm. Walleye Age: Scale and Spine Analysis (1987) Scales were taken from walleye that were shocked during the fall of 1987 electrofishing events on Lake Mendota. Scales were taken from 10 fish per one-inch length increment. The scales were removed from behind the left pectoral fin, and from the nape on the left side on esocids. In addition, the second dorsal spine was removed from 10 walleyes per sex and inch increment (to age and compare with scale ages for fish over 20 inches). CREEL SURVEYS1989:Fishing pressure, catch rates, harvest, and exploitation rates were estimated from a randomized, access-point creel survey. The schedule was stratified into weekday and weekend/holiday day types. Shifts were selected randomly and were either 07:00-15:00 h or 15:00-23:00 h. In addition, two 23:00-03:00 h shifts and two 03:00-07:00 h shifts were sampled per month to estimate the same parameters during night time hours. During the ice fishing season (January-February) 22 access points around Lake Mendota and upstream to the Highway 113 bridge were sampled. The clerk counted the number of anglers starting and completing trips during the scheduled stop at each access point. During openwater (March-December) 13 access points were sampled; 10 were boat ramps and 3 were popular shore fishing sites<strong>. </strong>At each of these sites, an instantaneous count of shore anglers was made upon arrival at the site, continuous counts of anglers starting and completing trips at public and private access points were made. Boat occupants and ice fishing anglers were only interviewed if they were completing a trip. Both complete and incomplete interviews were made of shore anglers. Number caught and number kept of each species, and percent of time seeking a particular species were recorded. All predators possessed by anglers were measured, weighed, and inspected for finclips and tags. We measured a random sample of at least 20 fish of each non-predator species per day.1990-1993: Same as 1989, except 23 access points were used during the ice fishing season. In addition, 13 access points were sampled during the openwater (May-December) season; 9 sites were boat ramps and 4 sites were popular shore fishing sites. 1994-1999: No formal documentation exists, but given the similarity in the data and consistency through the years; it is speculated tha tthe methods are the same.
Version Number
19

Trout Lake USGS Water, Energy, and Biogeochemical Budgets (WEBB) Stream Data 1975-current

Abstract
This data was collected by the United States Geological Survey (USGS) for the Water, Energy, and Biogeochemical Budget Project. The data set is primarily composed of water chemistry variables, and was collected from four USGS stream gauge stations in the Northern Highland Lake District of Wisconsin, near Trout Lake. The four USGS stream gauge stations are Allequash Creek at County Highway M (USGS-05357215), Stevenson Creek at County Highway M (USGS-05357225), North Creek at Trout Lake (USGS-05357230), and the Trout River at Trout Lake (USGS-05357245), all near Boulder Junction, Wisconsin. The project has collected stream water chemistry data for a maximum of 36 different chemical parameters,. and three different physical stream parameters: temperature, discharge, and gauge height. All water chemistry samples are collected as grab samples and sent to the USGS National Water Quality Lab in Denver, Colorado. There is historic data for Stevenson Creek from 1975-1977, and then beginning again in 1991. The Trout Lake WEBB project began during the summer of 1991 and sampling of all four sites continues to date.
Creator
Dataset ID
276
Date Range
-
Maintenance
Completed.
Metadata Provider
Methods
DL is used to represent “detection limit” where known.NOTE (1): Each method listed below corresponds with a USGS Parameter Code, which is listed after the variable name. NOTE (2): If the NEMI method # is known, it is also specified at the end of each method description.NOTE (3): Some of the variables are calculated using algorithms within QWDATA. If this is the case see Appendix D of the NWIS User’s Manual for additional information. However, appendix D does not list the algorithm used by the USGS. If a variable is calculated with an algorithm the term: algor, will be listed after the variable name.anc: 99431, Alkalinity is determined in the field by using the gran function plot methods, see TWRI Book 9 Chapter A6.1. anc_1: 90410 and 00410, Alkalinity is determined by titrating the water sample with a standard solution of a strong acid. The end point of the titration is selected as pH 4.5. See USGS TWRI 5-A1/1989, p 57, NEMI method #: I-2030-89.2. c13_c12_ratio: 82081, Exact method unknown. The following method is suspected: Automated dual inlet isotope ratio analysis with sample preparation by precipitation with ammoniacal strontium chloride solution, filtration, purification, acidified of strontium carbonate; sample size is greater than 25 micromoles of carbon; one-sigma uncertainty is approximately ± 0.1 ‰. See USGS Determination of the delta13 C of Dissolved Inorganic Carbon in Water, RSIL Lab Code 1710. Chapter 18 of Section C, Stable Isotope-Ratio Methods Book 10, Methods of the Reston Stable Isotope Laboratory.3. ca, mg, mn, na, and sr all share the same method. The USGS parameter codes are listed first, then the method description with NEMI method #, and finally DL’s:ca- 00915, mg- 00925, mn- 01056, na- 00930, sr- 01080All metals are determined simultaneously on a single sample by a direct reading emission spectrometric method using an inductively coupled argon plasma as an excitation source. Samples are pumped into a crossflow pneumatic nebulizer, and introduced into the plasma through a spray chamber and torch assembly. Each analysis is determined on the basis of the average of three replicate integrations, each of which is background corrected by a spectrum shifting technique except for lithium (670.7 nm) and sodium (589.0 nm). A series of five mixed-element standards and a blank are used for calibration. Method requires an autosampler and emission spectrometry system. See USGS OF 93-125, p 101, NEMI Method #: I-1472-87.DL’s: ca- .02 mg/l, mg-.01 mg/l, mn-1.0 ug/l, na- .2 mg/l, sr- .5 ug/l4. cl, f, and so4 all share the same method. The USGS parameter codes are listed first, then the method description with NEMI method #, and finally DL’s:cl- 00940, f-00950, so4-00945All three anions (chloride, flouride, and sulfate) are separated chromatographically following a single sample injection on an ion exchange column. Ions are separated on the basis of their affinity for the exchange sites of the resin. The separated anions in their acid form are measured using an electrical conductivity cell. Anions are identified on the basis of their retention times compared with known standards. 19 The peak height or area is measured and compared with an analytical curve generated from known standards to quantify the results. See USGS OF 93-125, p 19, NEMI method #: I-2057.DL’s: cl-.2 mg/l, f-.1 mg/l, so4-.2 mg/lco2: 00405, algor, see NWIS User's Manual, QW System, Appendix D, Page 285.co3: 00445, algor.color: 00080, The color of the water is compared to that of the colored glass disks that have been calibrated to correspond to the platinum-cobalt scale of Hazen (1892), See USGS TWRI 5-A1 or1989, P.191, NEMI Method #: I-1250. DL: 1 Pt-Co colorconductance_field: 00094 and 00095, specific conductance is determined in the field using a standard YSI multimeter, See USGS TWRI 9, 6.3.3.A, P. 13, NEMI method #: NFM 6.3.3.A-SW.conductance_lab: 90095, specific conductance is determined by using a wheat and one bridge in which a variable resistance is adjusted so that it is equal to the resistance of the unknown solution between platinized electrodes of a standardized conductivity cell, sample at 25 degrees celcius, See USGS TWRI 5-A1/1989, p 461, NEMI method #: I-1780-85.dic: 00691, This test method can be used to make independent measurements of IC and TC and can also determine TOC as the difference of TC and IC. The basic steps of the procedure are as follows:(1) Removal of IC, if desired, by vacuum degassing;(2) Conversion of remaining inorganic carbon to CO<sub>2</sub> by action of acid in both channels and oxidation of total carbon to CO<sub>2</sub> by action of ultraviolet (UV) radiation in the TC channel. For further information, See ASTM Standards, NEMI method #: D6317. DL: n/adkn: 00623 and 99894, Organic nitrogen compounds are reduced to the ammonium ion by digestion with sulfuric acid in the presence of mercuric sulfate, which acts as a catalyst, and potassium sulfate. The ammonium ion produced by this digestion, as well as the ammonium ion originally present, is determined by reaction with sodium salicylate, sodium nitroprusside, and sodium hypochlorite in an alkaline medium. The resulting color is directly proportional to the concentration of ammonia present, see USGS TWRI 5-A1/1989, p 327, NEMI method #: 351.2. DL: .10 mg/Ldo: 0300, Dissolved oxygen is measured in the field with a standard YSI multimeter, NEMI Method #: NFM 6.2.1-Lum. DL: 1 mg/L.doc: 00681, The sample is acidified, purged to remove carbonates and bicarbonates, and the organic carbon is oxidized to carbon dioxide with persulfate, in the presence of an ultraviolet light. The carbon dioxide is measured by nondispersive infrared spectrometry, see USGS OF 92-480, NEMI Method #: O-1122-92. DL: .10 mg/L.don: 00607, algor, see NWIS User's Manual, QW System, Appendix D, page 291.dp: 00666 and 99893, All forms of phosphorus, including organic phosphorus, are converted to orthophosphate ions using reagents and reaction parameters identical to those used in the block digester procedure for determination of organic nitrogen plus ammonia, that is, sulfuric acid, potassium sulfate, and mercury (II) at a temperature of 370 deg, see USGS OF Report 92-146, or USGS TWRI 5-A1/1979, p 453, NEMI method #: I-2610-91. DL= .012 mg/L.fe: 01046, Iron is determined by atomic absorption spectrometry by direct aspiration of the sample solution into an air-acetylene flame, see USGS TWRI 5-A1/1985, NEMI method #: I-1381. DL= 10µg/L.h_ion: 00191, algor.h20_hardness: 00900, algor.h20_hardness_2: 00902, algor.hco3: 00440, algor.k: 00935, Potassium is determined by atomic absorption spectrometry by direct aspiration of the sample solution into an air-acetylene flame , see USGS TWRI 5-A1/1989, p 393, NEMI method #: I-1630-85. DL= .01 mg/L.n_mixed: 00600, algor.n_mixed_1: 00602, algor.n_mixed_2: 71887, algor.nh3_nh4: 00608, Ammonia reacts with salicylate and hypochlorite ions in the presence of ferricyanide ions to form the salicylic acid analog of indophenol blue (Reardon and others, 1966; Patton and Crouch, 1977; Harfmann and Crouch, 1989). The resulting color is directly proportional to the concentration of ammonia present, See USGS OF 93-125, p 125/1986 (mg/l as N), NEMI Method #: I-2525. DL= .01 mg/L.nh3_nh4_1: 71846, algor.nh3_nh4_2: 00610, same method as 00608, except see USGS TWRI 5-A1/1989, p 321. DL = .01 mg/L.nh3_nh4_3: 71845, algor.no2: 00613, Nitrite ion reacts with sulfanilamide under acidic conditions to form a diazo compound which then couples with N-1-naphthylethylenediamine dihydrochloride to form a red compound, the absorbance of which is measured colorimetrically, see USGS TWRI 5-A1/1989, p 343, NEMI method #: I-2540-90. DL= .01 mg/L.no2_2: 71856, algor.no3: 00618, Nitrate is determined sequentially with six other anions by ion-exchange chromatography, see USGS TWRI 5-A1/1989, P. 339, NEMI method #: I-2057. DL= .05 mg/L.no3_2: 71851, algor.no32: 00630, An acidified sodium chloride extraction procedure is used to extract nitrate and nitrite from samples of bottom material for this determination(Jackson, 1958). Nitrate is reduced to nitrite by cadmium metal. Imidazole is used to buffer the analytical stream. The sample stream then is treated with sulfanilamide to yield a diazo compound, which couples with N-lnaphthylethylenediamine dihydrochloride to form an azo dye, the absorbance of which is measured colorimetrically. Procedure is used to extract nitrate and nitrite from bottom material for this determination (Jackson, 1958), see USGS TWRI 5-A1/1989, p 351. DL= .1 mg/Lno32_2: 00631, same as description for no32, except see USGS OF 93-125, p 157. DL= .1 mg/L.o18_o16_ratio: 82085, Sample preparation by equilibration with carbon dioxide and automated analysis; sample size is 0.1 to 2.0 milliliters of water. For 2-mL samples, the 2-sigma uncertainties of oxygen isotopic measurement results are 0.2 ‰. This means that if the same sample were resubmitted for isotopic analysis, the newly measured value would lie within the uncertainty bounds 95 percent of the time. Water is extracted from soils and plants by distillation with toluene; recommended sample size is 1-5 ml water per analysis, see USGS Determination of the Determination of the delta (18 O or 16O) of Water, RSIL Lab Code 489.o2sat: Dissolved oxygen is measured in the field with a standard YSI multimeter, which also measures % oxygen saturation, NEMI Method #: NFM 6.2.1-Lum.ph_field: 00400, pH determined in situ, using a standard YSI multimeter, see USGS Techniques of Water-Resources Investigations, book 9, Chaps. A1-A9, Chap. A6.4 "pH," NEMI method # NFM 6.4.3.A-SW. DL= .01 pH.ph_lab: 00403, involves use of laboratory pH meter, see USGS TWRI 5-A1/1989, p 363, NEMI method #: I-1586.po4: 00660, algor, see NWIS User's Manual, QW System, Appendix D, Page 286.po4_2: 00671, see USGS TWRI 5-A1/1989, NEMI method #: I-2602. DL= .01 mg/L.s: 63719, cannot determine exact method used. USGS method code: 7704-34-9 is typically used to measure sulfur as a percentage, with an DL =.01 µg/L. It is known that the units for sulfur measurements in this data set are micrograms per liter.sar: 00931, algor, see NWIS User's Manual, QW System, Appendix D, Page 288.si: 00955, Silica reacts with molybdate reagent in acid media to form a yellow silicomolybdate complex. This complex is reduced by ascorbic acid to form the molybdate blue color. The silicomolybdate complex may form either as an alpha or beta polymorph or as a mixture of both. Because the two polymorphic forms have absorbance maxima at different wavelengths, the pH of the mixture is kept below 2.5, a condition that favors formation of the beta polymorph (Govett, 1961; Mullen and Riley, 1955; Strickland, 1952), see USGS TWRI 5-A1/1989, p 417, NEMI method #: I-2700-85. DL= .10 mg/L.spc: 00932, algor, see NWIS User's Manual, QW System, Appendix D, Page 289.tds: 70300 and 70301, A well-mixed sample is filtered through a standard glass fiber filter. The filtrate is evaporated and dried to constant weight at 180 deg C, see " Filterable Residue by Drying Oven," NEMI method #: 160.1, DL= 10 mg/l. Note: despite DL values occur in the data set that are less than 10 mg/l.tds_1: 70301, algor, see NWIS User's Manual, QW System, Appendix D, Page 289.tds_2: 70303, algor, see NWIS User's Manual, QW System, Appendix D, Page 290.tkn: 00625 and 99892, Block digester procedure for determination of organic nitrogen plus ammonia, that is, sulfuric acid, potassium sulfate, and Mercury (II) at a temperature of 370°C. See the USGS Open File Report 92-146 for further details. DL: .10 mg/L.toc: 00680, The sample is acidified, purged to remove carbonates and bicarbonates, and the organic carbon is oxidized to carbon dioxide with persulfate, in the presence of an ultraviolet light. The carbon dioxide is measured by nondispersive infrared spectrometry, see USGS TWRI 5-A3/1987, p 15, NEMI Method #: O-1122-92. DL=.10 mg/L.ton: 00605, algor, See NWIS User's Manual, QW System, Appendix D, page 286.tp: 00665 and 99891, This method may be used to analyze most water, wastewater, brines, and water-suspended sediment containing from 0.01 to 1.0 mg/L of phosphorus. Samples containing greater concentrations need to be diluted, see USGS TWRI 5-A1/1989, p 367, NEMI method #: I-4607. tp_2: 71886, algor.tpc: 00694, The basic steps of this test method are:1) Conversion of remaining IC to CO2 by action of acid, 2) Removal of IC, if desired, by vacuum degassing, 3) Split of flow into two streams to provide for separate IC and TC measurements, 4) Oxidation of TC to CO2 by action of acid-persulfate aided by ultraviolet (UV) radiation in the TC channel, 5) Detection of CO2 by passing each liquid stream over membranes that allow the specific passage of CO2 to high-purity water where change in conductivity is measured, and 6) Conversion of the conductivity detector signal to a display of carbon concentration in parts per million (ppm = mg/L) or parts per billion (ppb = ug/L). The IC channel reading is subtracted from the TC channel reading to give a TOC reading, see ASTM Standards, NEMI Method #: D5997. DL= .06 µg/L.tpn: 49570, A weighed amount of dried particulate (from water) or sediment is combusted at a high temperature using an elemental analyzer. The combustion products are passed over a copper reduction tube to covert nitrogen oxides to molecular nitrogen. Carbon dioxide, nitrogen, and water vapor are mixed at a known volume, temperature, and pressure. The concentrations of nitrogen and carbon are determined using a series of thermal conductivity detectors/traps, measuring in turn by difference hydrogen (as water vapor), carbon (as carbon dioxide), and nitrogen (as molecular nitrogen). Procedures also are provided to differentiate between organic and inorganic carbon, if desired, see USEPA Method 440, NEMI method #: 440. DL= .01 mg/L.
Short Name
TL-USGS-WEBB Data
Version Number
15
Subscribe to water quality