US Long-Term Ecological Research Network

North Temperate Lakes LTER: Physical and Chemical Limnology of Lake Kegonsa and Lake Waubesa 1994 - current

Abstract
Physical and chemicals parameters of two Madison-area lakes in the Yahara chain not included as core NTL-LTER study lakes. Parameters include intermittently sampled water temperature, dissolved oxygen, ph, total alkalinity, chloride and sulfate. Nutrient data has been collected since 2015. Number of sites: 2.
Dataset ID
401
Date Range
-
DOI
10.6073/pasta/cc6f0e4d317d29200234c7243471472a
Maintenance
ongoing
Metadata Provider
Methods
see abstract
Short Name
NTLCH01
Version Number
1

North Temperate Lakes LTER Long-term winter chemical limnology and days since ice-on for primary study lakes 1983 - 2014

Abstract
This data set integrates long-term data sets on winter nutrient chemistry with ice phenology (number of days since ice-on), focusing on the subset of measurements taken during ice cover. Parameters characterizing limnology of 5 primary lakes (Allequash, Big Muskellunge, Crystal, Sparkling, and Trout lakes, are measured at one station in the deepest part of each lake at the surface, middle, and deep (~1 meter above bottom). These parameters include nitrate-N, ammonium-N, total dissolved phosphorus, dissolved inorganic carbon, water temperature, dissolved oxygen, and pH. Water temperature and dissolved oxygen values are the zonal averages from more complete depth profiles. Sampling Frequency: every 6 weeks during ice-covered season for the northern lakes. Number of sites: 5
Dataset ID
341
Date Range
-
Maintenance
completed
Methods
This is a compilation of three data sets

North Temperate Lakes LTER: Chemical Limnology of Primary Study Lakes: Nutrients, pH and Carbon 1981 - current
https://lter.limnology.wisc.edu/dataset/north-temperate-lakes-lter-chemical-limnology-primary-study-lakes-nutrients-ph-and-carbon-19

North Temperate Lakes LTER: Physical Limnology of Primary Study Lakes 1981 - current
https://lter.limnology.wisc.edu/dataset/north-temperate-lakes-lter-physical-limnology-primary-study-lakes-1981-current

North Temperate Lakes LTER: Ice Duration - Trout Lake Area 1981 - current
https://lter.limnology.wisc.edu/dataset/north-temperate-lakes-lter-ice-duration-trout-lake-area-1981-current
Version Number
6

River Nutrient Uptake and Transport at North Temperate Lakes LTER (2005-2011)

Abstract
These data were collected by Stephen Michael Powers and collaborators for his Ph.d. research, documented in his dissertation: River Nutrient Uptake and Transport Across Extremes in Channel Form and Drainage Characteristics. A major goal of this research was to better understand how ecosystem form and landscape setting dictate aquatic biogeochemical functioning and elemental transport through rivers. To achieve this goal, major and minor ions were measured in both northern and southern Wisconsin streams located in a variety of land use settings. In total, 27 different streams were sampled at 104 different stations (multiple stations per system) from both groundwater and surface water sources. Organic and inorganic carbon and nitrogen pools were also measured in northern and southern Wisconsin streams. The streams that were sampled in northern Wisconsin flow through wetland ecosystems. In sampling such streams, the goal was to better understand how wetland ecosystems influence river nutrient deliveries. There is a large amount of stream chemistry data for Big Spring Creek, WI; where the influence of a small reservoir on solute transportation and transformation was studied in an agricultural watershed. All stream chemistry data is incorporated in a single data file, Water Chemistry 2005-2011. While the data is not included in the dissertation, a sediment core study was also done in the small reservoir and channel of Big Spring (BS) Creek, WI. The results of this study are featured in three data tables: BS Creek Sediment Core Analysis, BS Creek Sediment Core Chemistry, and BS Creek Longitudinal Profile. Finally, two data tables list the geospatial information of sampling sites for stream chemistry and sediment coring in Big Spring Creek. Documentation: Powers, S.M., 2012. River nutrient uptake and transport across extremes in channel form and drainage characteristics. ProQuest Dissertations and Theses. The University of Wisconsin - Madison, United States -- Wisconsin, p. 140.
Dataset ID
281
Date Range
-
Metadata Provider
Methods
I. Stream chemistry sample collection methods: core-sediment core was taken from the benthic zone of the streamgeopump-geopump used to pump stream water into collection bottlegrab-collection bottle filled with stream water by hand and filtered in the fieldgrabfilter- stream water collected by hand and filtered in field. Unfiltered and filtered samples placed in separate collection bottles.isco- sample collected by use of an ISCO automated samplerpoint- sampled collected by method outlined in patent US8337121sedimentgrab- sediment sample taken in field by hand and placed in collection bottlesyringe- sample collected from stream by syringe and placed in collection bottlesyringe_filter- sample collected from stream by syringe filter. Unfiltered and filtered samples placed in separate collection bottles. II. Stream chemistry analytical methods: All water samples were kept on ice and in the dark following collection, then were either acidified (TN/TP, TDN/TDP) or frozen until analysis (all other analytes).no32_2- This is NO<sub>3-</sub>N which is operationally defined as nitrate nitrogen + nitrite nitrogen. Determined by flow injection analysis on Astoria Pacific Instruments Autoanalyzer (APIA).nh4_n, tn1, tp1, tdn, tdp- All analytes measured by flow injection analysis on Astoria Pacific Instruments Autoanalyzer (APIA).srp- measured colorometrically using the molybdate blue method [APHA 1995] and a Beckman spectrophotometer.doc- measured using a Shimadzu carbon analyzer.doc_qual- the goal in doing this analysis is to determine the source of dissolved organic carbon (doc) measured in a particular riverine ecosystem. This was achieved by UV absorbance which provides an estimate of the aromaticity of the doc in a sample, and by extension, the potential source of the doc.cl, no2, no3, br, and so4- all measured by ion chromatography. See http://www.nemi.gov; method number 4110C. Detection limits for method number 4110C: cl-20&micro;g/l, no2-15&micro;g/l, no3-17&micro;g/l, br-75&micro;g/l, and so4-75&micro;g/l.ysi_cond, do, ph_field, wtemp- all measured by use of a standard YSI meter.tss- measured by standard methods. A thoroughly mixed sample is filtered and dried at 103-105 degreesCelcius. The obtained residue represents the amount of solids suspended in the sample solution. See http://www.nemi.giv; method number D5907.tot_om- measured by standard methods. The residue obtained from the tss procedure is ignited at 550 degreesCelcius and weighed, the difference in weight representing total volatile solids. Total volatile solids represents the portion of the residue that is composed of organic molecules. See http://www.nemi.gov; method number 160.4.turbid- measured by use of a nephelometer. III. Big Spring Sediment Coring Methods A. Field Methods- collecting sediment coresSediment core samples taken with WDNR piston core samplerB. Sediment Analysis- HydrometerDocumentation: Robertson, G.P., Coleman, D.C., Bledsoe, C.S. and Sollins, P., 1999. Standard Soil Methods for Long-Term Ecological Research. Oxford University Press, New York, 462 pp.Hydrometer Analysis- procedure used to determine percent clay:<p style="margin-left:.25in;">1. Dry the sample in a pre-weighed aluminum pan for at least 24 hr at 105 C. Make sure sample is completely dry before weighing.<p style="margin-left:.25in;">2. Weigh the dried sample, then ash for at least 8 hr at 550 C. Make sure to break up any large clumps before ashing.<p style="margin-left:.25in;">3. Weigh the ashed sample, then crush any aggregates with a pestal. Mix sample thoroughly.<p style="margin-left:.25in;">4. Transfer 40g, plus or minus one gram, of the sample into a 500mL wide mouth bottle<p style="margin-left:.25in;">5. Add 10g of sodium hexametaphosphate to the bottle.<p style="margin-left:.25in;">6. Add approx 200mL of deionized water to bottle. Shake vigorously with hand.<p style="margin-left:.25in;">7. Stir samples on shaker table for at least 8 hr at speed 40. Putting them in a box and fastening with bungee cords works best.<p style="margin-left:.25in;">8. Transfer sample to 1L cylinder, making sure to get all of sample out of bottle. Fill cylinder with deionized water up to the 1L mark.<p style="margin-left:.25in;">9. Prepare a blank cylinder by adding 10g of sodium hexametaphosphate and filling to 1L.<p style="margin-left:.25in;">10. Allow all cylinders to equilibrate to room temperature ( approx 30 min).<p style="margin-left:.25in;">11. Starting with the blank cylinder, put stopper into cylinder and shake end-over-end for approx 5 min. Rinse stopper. Repeat this step for all cylinders, rinsing stopper between cylinders.<p style="margin-left:.25in;">12. Record the time that you stopped shaking each cylinder.<p style="margin-left:.25in;">13. At 1.5 hr from time of shaking, record temperature and hydrometer level of the blank cylinder. Then record the 1.5 hr hydrometer level for each successive cylinder.<p style="margin-left:.25in;">14. At 24 hr from time of shaking, record temperature and hydrometer level of the blank cylinder. Then record the 24 hr hydrometer level for each successive cylinder. Sieve Analysis- procedure used to determine quantity of sand and silt<p style="margin-left:.25in;">1. After hydrometer analysis, pour the entire sample into the .063mm sieve. Rinse the sample thoroughly until all the clay is out. Try to break up any clay clumps you see.<p style="margin-left:.25in;">2. Transfer the sample to a pre-weighed and labeled aluminum pan. You will probably need to backwash the sieve to get the entire sample out. You can use a syringe to pull water from the pan if it gets too full. Dry the sample for 48 hours at 50-60C.<p style="margin-left:.25in;">3. Before transferring the dried sample to the sieves, make sure you pre-weigh the sieves and put their weight on the data sheet. You will need to do this before every sample as you might not get all the sample out of the sieves from the previous sample. Stack the sieves in the following order, top to bottom : 4mm, 2mm, 1mm, 0.5mm, 0.25mm, 0.125mm, 0.063mm, and pan. Pour the sample into the top sieve. Place the lid on, located on sieve shaker, and put the stack of sieves into the sieve shaker. Fasten the tie downs. Set shaker for 3 minutes. <p style="margin-left:.25in;">4. Remove stack of sieves from shaker. It&rsquo;s ok to leave the pan behind temporarily as it might be tight. Weigh each sieve and record the weight in the data sheet. If you see any clay clumps, break them up with your fingers and re-shake the stack a little, using hands is okay.<p style="margin-left:.25in;">5. Dump the sample out in the trash and clean the sieve with the brush. At the end of the day it might be necessary to backwash the sieves with water and dry overnight in the oven. <p style="margin-left:.25in;"> Calculations:1. percent clay was determined by the hydrometer analysis- P1.5, P24, X1.5, X24, and m are the variables that were calculated to determine percent clay by the hydrometer analysis.P1.5= ((sample hydrometer reading at 1.5 hours- blank hydrometer reading at 1.5 hours)/ (sample weight)) multiplied by 100.P24= ((sample hydrometer reading at 24 hours- blank hydrometer reading at 24 hours)/ (sample weight)) multiplied by 100X1.5= 1000*(.00019*(-.164* (sample hydrometer reading at 1.5 hours)+16.3)<sup>2</sup> *8100X24=1000*(.00019*(-.164* (sample hydrometer reading at 24 hours)+16.3)<sup>2</sup> *8100m= (P1.5-P24)/(ln(X1.5/X24))percent clay = m * ln(2/X24)) + P24clay (grams) = total weight * ( percent clay/ 100)2. percent Sand and percent Silt were determined based on the results of the sieve analysis which determined the grams of sand and silt.percent sand= total weight * (percent sand/ 100)percent silt= total weight * (percent silt/ 100)3. Othersorganic matter (grams) was calculated in this analysis as dry weight (grams) &ndash; ashed weight (grams)percwnt organic matter was calculated as ((organic matter (grams))/(total dry weight (grams)) multiplied by 100 C. Sediment Chemical Analysis1. SRP/ NaOH-PChemical analysis was done according to the protocol outlined in Pionke and Kunishi (1992). Each sample was first centrifuged and separated into aqueous and sediment fractions. The sediment fraction was then dried. The aqueous fraction was analyzed for soluble reactive phosphorus (srp) by automated colorimetry Nemi Method Number 365.4; see http://www.nemi.gov. NaOH P was then determined by NaOH extractions as described in Pionke and Kunishi (1992). Documentation: Pionke HB, Kunishi HM (1992) Phosphorus status and content of suspended sediment in a Pennsylvania watershed. Soil Sci 153:452&ndash;462.2. NH4 / KCl-NH4 The exact procedure that was used to analyze samples for ammonium is unknown. However, it is known that a KCl extraction was used. The KCl-NH4 was calculated as the concentration of ammonium in milliGramsPerLiter divided by the sediment weight in grams. 3. NO3 / KCl-NO3The exact procedure that was used to analyze samples for nitrate is also unknown. Again, it is known that a KCL extraction was used. The KCl-NO3 was calculated as the concentration of nitrate in milliGramsPerLiter divided by the sediment weight in grams.Note: The same sediment sample was used to measure ammonium and nitrate IV. Big Spring Creek Longitudinal Profile A standard longitudinal stream profile was conducted at Big Spring Creek, WI (wbic=176400) on unknown date(s). It is speculated that the profile was done during the summer of 2005, during which the rest of the data for Big Spring Creek was collected. Measurements for the profile began at the Big Spring Dam site (43.67035,-89.64225), a dam which was subsequently removed. The first (x_dist, y_dist) of (2.296, 5.57) corresponds to the location where the stream crosses Golden Court Road, whereas the second coordinate pair of (-2.615, -36.303) corresponds to the point below the previous Big Spring Creek Dam site. The third (x_dist, y_dist) of (-9.472, 7.681) corresponds to the top of the dam gates and is assigned a distance=0 as it is the starting point.
Version Number
23

Fluxes project at North Temperate Lakes LTER: Random lake survey 2004

Abstract
The overarching goal of this project is to understand carbon and nutrient cycles for a landscape on which terrestrial and freshwater systems are intimately connected in multiple and reciprocal ways. In the Northern Highlands region of Wisconsin, they are studying a spatially complex landscape in which water features make up almost half of the land area, with wetlands (27% of land surface) and lakes (13%) both prevalent throughout the region, interspersed in upland forests.Weather and limnological data from a set of 170 lakes in the NHLD samples summer 2004. The sampled lakes were from a random stratified subsample (N=300 of 7588 total) of all the lakes in the NHLD.
Contact
Core Areas
Dataset ID
277
Date Range
-
Maintenance
completed
Metadata Provider
Methods
Hanson PC, Carpenter S, Cardille JA, Coe MT, Winslow LA. 2007. Small lakes dominate a random sample of regional lake characteristics. Freshwater Biology. 52:814-22Lakes were selected from unique Water Body Identification Codes (WBICs). Linear features and water bodies identified as impoundments or stream openings were identified from maps digitised by the Departments of Natural Resources of Michigan and Wisconsin (1 : 24 000 USGS 7.5&rsquo; topographic quadrangles) and were excluded. More than 7500 lakes ranging in size from about 0.01 to over 2800 ha remained in the data set. We used a stratified random survey, an approach consistent with the Environmental Monitoring and Assessment Program (EMAP) guidelines (Larsen et al., 1994) of the U.S. Environmental Protection Agency, to select and sample 300 lakes from the data set as follows. All lakes were ordered by area and divided into 20 bins of equal population. From each bin, 15 lakes were chosen at random. Because of logistical issues in travelling to many lakes scattered over a wide geographical region, we clustered lakes into 31 geographically small regions of about 150 km2 each. The order of regions sampled was randomised to reduce correlation of geographic region with time. For any one sampling date we visited only one region, although not all lakes in a region could be visited on a single trip. After all 31 regions were visited, the regions were again selected at random, and lakes previously not visited were sampled. There were 45 sampling days spread between May 20 and August 19. Some lakes that were chosen for sampling could not be visited. Difficulty portaging the sampling gear to a lake or failure to gain access to a lake through private property were reasons for abandoning a sampling effort.Lakes were sampled at their approximate geographic centre. Lake depth and water clarity were measured with a Secchi disk. Our measurement of lake depth was neither a measurement of the maximum nor the mean depth. Because the measurement was made in the middle of the lake and most lakes in the region tend to be bowl shaped, our measurement was probably between mean and maximum depth. Dissolved oxygen (DO) and thermal profiles were obtained from a YSI Model 58 (YSI, Inc., Yellow Springs, OH, U.S.A.) metre (DO air calibrated; temperature calibrated in the laboratory), and the approximate middle of the epilimnion was estimated from the profile. Thermal stratification was calculated from the thermal profile according to the methods listed on the Internet at the North Temperate Lakes Long Term Ecological Research (NTL-LTER) program Web site (http://lter.limnology.wisc.edu). Water samples for later analyses (Table 1, chemical variables) were obtained from the middle of the epilimnion, using a peristaltic pump. For samples that required filtration [dissolved inorganic carbon (DIC), DOC, cations and anions], a 0.45 μm filter was attached in-line. All samples were refrigerated upon returning to the vehicle, and samples for total nitrogen (TN) and total phosphorus (TP) were preserved by acidification. Acid neutralizing capacity (ANC) and pH were determined the day of sampling by Gran alkalinity titration (for ANC) and measurement by pH probe (Accumet 950; Fisher Scientific, Hanover Park, IL U.S.A.). pH was not air equilibrated. DIC and DOC were measured with a carbon analyzer (TOC-V; Shimadzu Scientific Instruments, Columbia, MD, U.S.A.). TN and TP were measured with a segmented flow auto-analyzer (Astoria-Pacific, Inc., Clackamas, OR, U.S.A.). Anions were measured using an ion chromatograph (DX500; Dionex Corporation, Sunnyvale, CA, U.S.A.), and cations using mass spectrometry (ICP-MS; PerkinElmer Life and Analytical Sciences, Shelton, CT, U.S.A.). Details of chemical analyses are available on the Internet at the NTL-LTER Web site listed above.To correct for bias introduced by not sampling all 300 lakes, we replaced missing data using multiple imputation (Levy, 1999). Multiple imputation is a technique for estimating the uncertainty of imputed variables. For each variable for each lake not sampled in a given bin, we chose at random (with replacement) a value from lakes sampled in that bin. We repeated the imputation 1000 times to provide a distribution of estimates for each variable in the lakes not sampled. The distribution mean for each variable in each lake was used in the calculation of the median for the regional lake population. We chose to present the median for the 300 lakes because distributions tended to be highly skewed. For comparison purposes, we also calculated the median from sampled lakes only (i.e. excluding imputed data). The mean cumulative distributions for some variables, including 95% confidence intervals, were plotted from the 1000 cumulative distributions generated by multiple imputation.We fit a Pareto distribution to the regional lake area data set to compare the size distribution of NHLD lakes with those of other regions. We used the maximum likelihood estimator for parameter estimates (Bernardo &amp; Smith, 2000). Of particular interest is the parameter (β) that describes the logarithmic decline in number of lakes with lake area, because this parameter has been used previously (Downing et al., 2006, Table 1) to compare lake area distributions among regions and to estimate the global abundance of lakes.Where indicated, results have been area weighted to reflect the influence of lake size. For correlations, data were transformed (log10) to normalise distributions and linearise relationships. Shoreline development factor (SDF), an index of the irregular shape of lakes, was calculated for each lake according to Kalff (2002). The minimum SDF, 1, indicates a lake is a perfect circle.
NTL Keyword
Version Number
25

Trout Lake USGS Water, Energy, and Biogeochemical Budgets (WEBB) Stream Data 1975-current

Abstract
This data was collected by the United States Geological Survey (USGS) for the Water, Energy, and Biogeochemical Budget Project. The data set is primarily composed of water chemistry variables, and was collected from four USGS stream gauge stations in the Northern Highland Lake District of Wisconsin, near Trout Lake. The four USGS stream gauge stations are Allequash Creek at County Highway M (USGS-05357215), Stevenson Creek at County Highway M (USGS-05357225), North Creek at Trout Lake (USGS-05357230), and the Trout River at Trout Lake (USGS-05357245), all near Boulder Junction, Wisconsin. The project has collected stream water chemistry data for a maximum of 36 different chemical parameters,. and three different physical stream parameters: temperature, discharge, and gauge height. All water chemistry samples are collected as grab samples and sent to the USGS National Water Quality Lab in Denver, Colorado. There is historic data for Stevenson Creek from 1975-1977, and then beginning again in 1991. The Trout Lake WEBB project began during the summer of 1991 and sampling of all four sites continues to date.
Creator
Dataset ID
276
Date Range
-
Maintenance
Completed.
Metadata Provider
Methods
DL is used to represent “detection limit” where known.NOTE (1): Each method listed below corresponds with a USGS Parameter Code, which is listed after the variable name. NOTE (2): If the NEMI method # is known, it is also specified at the end of each method description.NOTE (3): Some of the variables are calculated using algorithms within QWDATA. If this is the case see Appendix D of the NWIS User’s Manual for additional information. However, appendix D does not list the algorithm used by the USGS. If a variable is calculated with an algorithm the term: algor, will be listed after the variable name.anc: 99431, Alkalinity is determined in the field by using the gran function plot methods, see TWRI Book 9 Chapter A6.1. anc_1: 90410 and 00410, Alkalinity is determined by titrating the water sample with a standard solution of a strong acid. The end point of the titration is selected as pH 4.5. See USGS TWRI 5-A1/1989, p 57, NEMI method #: I-2030-89.2. c13_c12_ratio: 82081, Exact method unknown. The following method is suspected: Automated dual inlet isotope ratio analysis with sample preparation by precipitation with ammoniacal strontium chloride solution, filtration, purification, acidified of strontium carbonate; sample size is greater than 25 micromoles of carbon; one-sigma uncertainty is approximately ± 0.1 ‰. See USGS Determination of the delta13 C of Dissolved Inorganic Carbon in Water, RSIL Lab Code 1710. Chapter 18 of Section C, Stable Isotope-Ratio Methods Book 10, Methods of the Reston Stable Isotope Laboratory.3. ca, mg, mn, na, and sr all share the same method. The USGS parameter codes are listed first, then the method description with NEMI method #, and finally DL’s:ca- 00915, mg- 00925, mn- 01056, na- 00930, sr- 01080All metals are determined simultaneously on a single sample by a direct reading emission spectrometric method using an inductively coupled argon plasma as an excitation source. Samples are pumped into a crossflow pneumatic nebulizer, and introduced into the plasma through a spray chamber and torch assembly. Each analysis is determined on the basis of the average of three replicate integrations, each of which is background corrected by a spectrum shifting technique except for lithium (670.7 nm) and sodium (589.0 nm). A series of five mixed-element standards and a blank are used for calibration. Method requires an autosampler and emission spectrometry system. See USGS OF 93-125, p 101, NEMI Method #: I-1472-87.DL’s: ca- .02 mg/l, mg-.01 mg/l, mn-1.0 ug/l, na- .2 mg/l, sr- .5 ug/l4. cl, f, and so4 all share the same method. The USGS parameter codes are listed first, then the method description with NEMI method #, and finally DL’s:cl- 00940, f-00950, so4-00945All three anions (chloride, flouride, and sulfate) are separated chromatographically following a single sample injection on an ion exchange column. Ions are separated on the basis of their affinity for the exchange sites of the resin. The separated anions in their acid form are measured using an electrical conductivity cell. Anions are identified on the basis of their retention times compared with known standards. 19 The peak height or area is measured and compared with an analytical curve generated from known standards to quantify the results. See USGS OF 93-125, p 19, NEMI method #: I-2057.DL’s: cl-.2 mg/l, f-.1 mg/l, so4-.2 mg/lco2: 00405, algor, see NWIS User's Manual, QW System, Appendix D, Page 285.co3: 00445, algor.color: 00080, The color of the water is compared to that of the colored glass disks that have been calibrated to correspond to the platinum-cobalt scale of Hazen (1892), See USGS TWRI 5-A1 or1989, P.191, NEMI Method #: I-1250. DL: 1 Pt-Co colorconductance_field: 00094 and 00095, specific conductance is determined in the field using a standard YSI multimeter, See USGS TWRI 9, 6.3.3.A, P. 13, NEMI method #: NFM 6.3.3.A-SW.conductance_lab: 90095, specific conductance is determined by using a wheat and one bridge in which a variable resistance is adjusted so that it is equal to the resistance of the unknown solution between platinized electrodes of a standardized conductivity cell, sample at 25 degrees celcius, See USGS TWRI 5-A1/1989, p 461, NEMI method #: I-1780-85.dic: 00691, This test method can be used to make independent measurements of IC and TC and can also determine TOC as the difference of TC and IC. The basic steps of the procedure are as follows:(1) Removal of IC, if desired, by vacuum degassing;(2) Conversion of remaining inorganic carbon to CO<sub>2</sub> by action of acid in both channels and oxidation of total carbon to CO<sub>2</sub> by action of ultraviolet (UV) radiation in the TC channel. For further information, See ASTM Standards, NEMI method #: D6317. DL: n/adkn: 00623 and 99894, Organic nitrogen compounds are reduced to the ammonium ion by digestion with sulfuric acid in the presence of mercuric sulfate, which acts as a catalyst, and potassium sulfate. The ammonium ion produced by this digestion, as well as the ammonium ion originally present, is determined by reaction with sodium salicylate, sodium nitroprusside, and sodium hypochlorite in an alkaline medium. The resulting color is directly proportional to the concentration of ammonia present, see USGS TWRI 5-A1/1989, p 327, NEMI method #: 351.2. DL: .10 mg/Ldo: 0300, Dissolved oxygen is measured in the field with a standard YSI multimeter, NEMI Method #: NFM 6.2.1-Lum. DL: 1 mg/L.doc: 00681, The sample is acidified, purged to remove carbonates and bicarbonates, and the organic carbon is oxidized to carbon dioxide with persulfate, in the presence of an ultraviolet light. The carbon dioxide is measured by nondispersive infrared spectrometry, see USGS OF 92-480, NEMI Method #: O-1122-92. DL: .10 mg/L.don: 00607, algor, see NWIS User's Manual, QW System, Appendix D, page 291.dp: 00666 and 99893, All forms of phosphorus, including organic phosphorus, are converted to orthophosphate ions using reagents and reaction parameters identical to those used in the block digester procedure for determination of organic nitrogen plus ammonia, that is, sulfuric acid, potassium sulfate, and mercury (II) at a temperature of 370 deg, see USGS OF Report 92-146, or USGS TWRI 5-A1/1979, p 453, NEMI method #: I-2610-91. DL= .012 mg/L.fe: 01046, Iron is determined by atomic absorption spectrometry by direct aspiration of the sample solution into an air-acetylene flame, see USGS TWRI 5-A1/1985, NEMI method #: I-1381. DL= 10µg/L.h_ion: 00191, algor.h20_hardness: 00900, algor.h20_hardness_2: 00902, algor.hco3: 00440, algor.k: 00935, Potassium is determined by atomic absorption spectrometry by direct aspiration of the sample solution into an air-acetylene flame , see USGS TWRI 5-A1/1989, p 393, NEMI method #: I-1630-85. DL= .01 mg/L.n_mixed: 00600, algor.n_mixed_1: 00602, algor.n_mixed_2: 71887, algor.nh3_nh4: 00608, Ammonia reacts with salicylate and hypochlorite ions in the presence of ferricyanide ions to form the salicylic acid analog of indophenol blue (Reardon and others, 1966; Patton and Crouch, 1977; Harfmann and Crouch, 1989). The resulting color is directly proportional to the concentration of ammonia present, See USGS OF 93-125, p 125/1986 (mg/l as N), NEMI Method #: I-2525. DL= .01 mg/L.nh3_nh4_1: 71846, algor.nh3_nh4_2: 00610, same method as 00608, except see USGS TWRI 5-A1/1989, p 321. DL = .01 mg/L.nh3_nh4_3: 71845, algor.no2: 00613, Nitrite ion reacts with sulfanilamide under acidic conditions to form a diazo compound which then couples with N-1-naphthylethylenediamine dihydrochloride to form a red compound, the absorbance of which is measured colorimetrically, see USGS TWRI 5-A1/1989, p 343, NEMI method #: I-2540-90. DL= .01 mg/L.no2_2: 71856, algor.no3: 00618, Nitrate is determined sequentially with six other anions by ion-exchange chromatography, see USGS TWRI 5-A1/1989, P. 339, NEMI method #: I-2057. DL= .05 mg/L.no3_2: 71851, algor.no32: 00630, An acidified sodium chloride extraction procedure is used to extract nitrate and nitrite from samples of bottom material for this determination(Jackson, 1958). Nitrate is reduced to nitrite by cadmium metal. Imidazole is used to buffer the analytical stream. The sample stream then is treated with sulfanilamide to yield a diazo compound, which couples with N-lnaphthylethylenediamine dihydrochloride to form an azo dye, the absorbance of which is measured colorimetrically. Procedure is used to extract nitrate and nitrite from bottom material for this determination (Jackson, 1958), see USGS TWRI 5-A1/1989, p 351. DL= .1 mg/Lno32_2: 00631, same as description for no32, except see USGS OF 93-125, p 157. DL= .1 mg/L.o18_o16_ratio: 82085, Sample preparation by equilibration with carbon dioxide and automated analysis; sample size is 0.1 to 2.0 milliliters of water. For 2-mL samples, the 2-sigma uncertainties of oxygen isotopic measurement results are 0.2 ‰. This means that if the same sample were resubmitted for isotopic analysis, the newly measured value would lie within the uncertainty bounds 95 percent of the time. Water is extracted from soils and plants by distillation with toluene; recommended sample size is 1-5 ml water per analysis, see USGS Determination of the Determination of the delta (18 O or 16O) of Water, RSIL Lab Code 489.o2sat: Dissolved oxygen is measured in the field with a standard YSI multimeter, which also measures % oxygen saturation, NEMI Method #: NFM 6.2.1-Lum.ph_field: 00400, pH determined in situ, using a standard YSI multimeter, see USGS Techniques of Water-Resources Investigations, book 9, Chaps. A1-A9, Chap. A6.4 "pH," NEMI method # NFM 6.4.3.A-SW. DL= .01 pH.ph_lab: 00403, involves use of laboratory pH meter, see USGS TWRI 5-A1/1989, p 363, NEMI method #: I-1586.po4: 00660, algor, see NWIS User's Manual, QW System, Appendix D, Page 286.po4_2: 00671, see USGS TWRI 5-A1/1989, NEMI method #: I-2602. DL= .01 mg/L.s: 63719, cannot determine exact method used. USGS method code: 7704-34-9 is typically used to measure sulfur as a percentage, with an DL =.01 µg/L. It is known that the units for sulfur measurements in this data set are micrograms per liter.sar: 00931, algor, see NWIS User's Manual, QW System, Appendix D, Page 288.si: 00955, Silica reacts with molybdate reagent in acid media to form a yellow silicomolybdate complex. This complex is reduced by ascorbic acid to form the molybdate blue color. The silicomolybdate complex may form either as an alpha or beta polymorph or as a mixture of both. Because the two polymorphic forms have absorbance maxima at different wavelengths, the pH of the mixture is kept below 2.5, a condition that favors formation of the beta polymorph (Govett, 1961; Mullen and Riley, 1955; Strickland, 1952), see USGS TWRI 5-A1/1989, p 417, NEMI method #: I-2700-85. DL= .10 mg/L.spc: 00932, algor, see NWIS User's Manual, QW System, Appendix D, Page 289.tds: 70300 and 70301, A well-mixed sample is filtered through a standard glass fiber filter. The filtrate is evaporated and dried to constant weight at 180 deg C, see " Filterable Residue by Drying Oven," NEMI method #: 160.1, DL= 10 mg/l. Note: despite DL values occur in the data set that are less than 10 mg/l.tds_1: 70301, algor, see NWIS User's Manual, QW System, Appendix D, Page 289.tds_2: 70303, algor, see NWIS User's Manual, QW System, Appendix D, Page 290.tkn: 00625 and 99892, Block digester procedure for determination of organic nitrogen plus ammonia, that is, sulfuric acid, potassium sulfate, and Mercury (II) at a temperature of 370°C. See the USGS Open File Report 92-146 for further details. DL: .10 mg/L.toc: 00680, The sample is acidified, purged to remove carbonates and bicarbonates, and the organic carbon is oxidized to carbon dioxide with persulfate, in the presence of an ultraviolet light. The carbon dioxide is measured by nondispersive infrared spectrometry, see USGS TWRI 5-A3/1987, p 15, NEMI Method #: O-1122-92. DL=.10 mg/L.ton: 00605, algor, See NWIS User's Manual, QW System, Appendix D, page 286.tp: 00665 and 99891, This method may be used to analyze most water, wastewater, brines, and water-suspended sediment containing from 0.01 to 1.0 mg/L of phosphorus. Samples containing greater concentrations need to be diluted, see USGS TWRI 5-A1/1989, p 367, NEMI method #: I-4607. tp_2: 71886, algor.tpc: 00694, The basic steps of this test method are:1) Conversion of remaining IC to CO2 by action of acid, 2) Removal of IC, if desired, by vacuum degassing, 3) Split of flow into two streams to provide for separate IC and TC measurements, 4) Oxidation of TC to CO2 by action of acid-persulfate aided by ultraviolet (UV) radiation in the TC channel, 5) Detection of CO2 by passing each liquid stream over membranes that allow the specific passage of CO2 to high-purity water where change in conductivity is measured, and 6) Conversion of the conductivity detector signal to a display of carbon concentration in parts per million (ppm = mg/L) or parts per billion (ppb = ug/L). The IC channel reading is subtracted from the TC channel reading to give a TOC reading, see ASTM Standards, NEMI Method #: D5997. DL= .06 µg/L.tpn: 49570, A weighed amount of dried particulate (from water) or sediment is combusted at a high temperature using an elemental analyzer. The combustion products are passed over a copper reduction tube to covert nitrogen oxides to molecular nitrogen. Carbon dioxide, nitrogen, and water vapor are mixed at a known volume, temperature, and pressure. The concentrations of nitrogen and carbon are determined using a series of thermal conductivity detectors/traps, measuring in turn by difference hydrogen (as water vapor), carbon (as carbon dioxide), and nitrogen (as molecular nitrogen). Procedures also are provided to differentiate between organic and inorganic carbon, if desired, see USEPA Method 440, NEMI method #: 440. DL= .01 mg/L.
Short Name
TL-USGS-WEBB Data
Version Number
15

South: Field Sampling Routine

A. Nutrient Sampling: Refer to the Field Sheet to see which bottles need to be sampled at which depths and the 'Southern Lakes LTER Bottle Codes’ for preservation, filtering, and coding information.
 
1.     Purge the lines: Whenever sampling from a new depth, the peristaltic pump tubing must be purged of the water from the previous depth. After reaching the proper sampling depth, use a graduated cylinder to measure the volume of water purged before beginning the sampling. Purge at least 1200 mL of water for each 20 meters of tu

North Temperate Lakes LTER: Groundwater Chemistry 1984 - current

Abstract
Water chemistry is measured annually in 11 monitoring wells to characterize regional groundwater chemistry in the Trout Lake area. The chemical parameters measured include pH, conductivity, total alkalinity, dissolved inorganic and organic carbon, total nitrogen, nitrate, ammonia, total phosphorus, calcium, magnesium, sodium, potassium, chloride, sulfate, iron, manganese, total silica and dissolved reactive silica. Chemical data are available at a quarterly sampling frequency for some years. In addition (see related data set - Groundwater Level), water levels in 37 monitoring wells are measured several times per year. The wells are scattered throughout the Trout Lake hydrological basin and the data are used to calibrate and test regional groundwater flow models. Sampling Frequency: annually - with some earlier data from quarterly sampling Number of sites: 11
Dataset ID
10
Date Range
-
Maintenance
ongoing
Metadata Provider
Methods
Ammonium, Nitrate, Nitrit Samples for ammonium and nitrate or nitrite are collected together with a peristaltic pump and tubing and in-line filtered (through a 0.40 micron polycarbonate filter) into new, 20 ml HDPE plastic containers with conical caps. The samples are stored frozen until analysis, which should occur within 6 months. The samples are analyzed for ammonium (and nitrateornitrite) simultaneously by automated colorimetric spectrophotometry, using a segmented flow autoanalyzer. Ammonium is determined by utilizing the Berthelot Reaction, producing a blue colored indophenol compound, where the absorption is monitored at 660 nm. The detection limit for ammonium is approximately 3 ppb and the analytical range for the method extends to 4000 ppb. The detection limit for nitrateornitrite is approximately 2 ppb and the analytical range for the method extends to 4000 ppb. Method Log: Prior to January 2006 samples, ammonium was determined on a Technicon segmented flow autoanalyzer. From 2006 to present, ammonium is determined by an Astoria-Pacific Astoria II segmented flow autoanalyzer. Chloride, Sulfate Samples for chloride and sulfate are collected together with a peristaltic pump and tubing and in-line filtered (through a 0.40 micron polycarbonate filter) into new, 20 ml HDPE plastic containers with conical caps. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 6 months. The samples are analyzed for chloride (and sulfate) simultaneously by Ion Chromatography, using a hydroxide eluent. The detection limit for chloride is approximately 0.01 ppm and the analytical range for the method extends to 100 ppm. The detection limit for sulfate is approximately 0.01 ppm and the analytical range for the method extends to 60 ppm. Method Log: Prior to January 1998 samples, chloride was determined on a Dionex DX10 Ion Chromatograph, using a chemical fiber suppressor. From 1998 to 2011, chloride was determined by a Dionex model DX500, using an electro-chemical suppressor. From January 2011 until present, chloride is determined by a Dionex model ICS 2100 using an electro-chemical suppressor. Calcium, magnesium, sodium, potassium, iron, and manganese Samples for calcium analysis (as well as dissolved nitrogen and phosphorus, magnesium, sodium, potassium, iron, and manganese) are collected together with a peristaltic pump and tubing and in-line filtered (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 ml of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. Calcium, as well as magnesium, sodium, potassium, iron, and manganese are analyzed simultaneously on an optical inductively-coupled plasma emission spectrophotometer (ICP-OES). The acidified samples are directly aspirated into the instrument without a digestion. Calcium is analyzed at 317.933 nm and at 315.887 nm and viewed axially for low-level analysis and radially for high level analysis. The detection limit for calcium is 0.06 ppm with an analytical range of the method extends to 50 ppm. The detection limit for iron is 0.02 ppm with an analytical range of the method extends to 20 ppm. The detection limit for magnesium is 0.03 ppm with an analytical range of the method extends to 50 ppm. The detection limit for manganese is 0.01 ppm with an analytical range of the method extends to 2 ppm. The detection limit for potassium is 0.06 ppm with an analytical range of the method extends to 10 ppm. The detection limit for sodium is 0.06 ppm with an analytical range of the method extends to 50 ppm. Method Log: Prior to January 2002, calcium, magnesium, sodium, potassium, iron, and manganese were determined on a Perkin-Elmer model 503 Atomic Absorption Spectrophotometer. Lanthanum at a 0.8percent concentration was added as a matrix modifier to suppress chemical interferences. From January 2002 to present, samples are analyzed for calcium on a Perkin-Elmer model 4300 DV ICP. Inorganic and organic carbon Samples for inorganic and organic carbon are collected together with a peristaltic pump and tubing and in-line filtered, if necessary, (through a 0.40 micron polycarbonate filter) into glass, 24 ml vials (that are compatible with the carbon analyzer autosampler), and capped with septa, leaving no head space. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 2-3 weeks. The detection limit for inorganic carbon is 0.15 ppm, and the analytical range for the method is 60 ppm. The detection limit for organic carbon is 0.30 ppm and the analytical range for the method is 30 ppm. Method Log: Prior to May 2006 samples, inorganic carbon was analyzed by phosphoric acid addition on an OI Model 700 Carbon Analyzer. From May 2006 to present, inorganic carbon is still analyzed by phosphoric acid addition, but on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer. Method Log: Prior to May 2006 samples, organic carbon was analyzed by heated persulfate digestion on an OI Model 700 Carbon Analyzer. From May 2006 to present, Organic carbon is analyzed by combustion, on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer. Dissolved reactive silicon Samples for silicon are collected with a peristaltic pump and tubing and in-line filtered (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 ml of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. Dissolved reactive silica is determined by the Heteropoly Blue Method and the absorption is measured at 820 nm. The detection limit for silicon is 6 ppb and the analytical range is 15000 ppb. Method Log These determinations were performed manually using a Bausch and Lomb Spectrophotometer from the beginning of the project until April 1984. From 1984 through 2005, dissolved reactive silicon was determined on a Technicon Auto Analyzer II. From January 2006 to present, samples are run on an Astoria-Pacific Astoria II Autoanalyzer. total and dissolved nitrogen and phosphorus Samples for total and dissolved nitrogen and phosphorus analysis are collected together with a peristaltic pump and tubing and in-line filtered, when necessary, (through a 40 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 mL of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. The samples must first be prepared for analysis by adding an NaOH–Persulfate digestion reagent and heated for an hour at 120 degrees C and 18-20 psi in an autoclave. The samples are analyzed for total nitrogen and total phosphorus simultaneously by automated colorimetric spectrophotometry, using a segmented flow autoanalyzer. Total nitrogen is determined by utilizing the automated cadmium reduction method, as described in Standard Methods, where the absorption is monitored at 520 nm. The detection limit for total and dissolved nitrogen is approximately 21 ppb and the analytical range for the method extends to 2500 ppb. The detection limit for total phosphorus is approximately 3 ppb and the analytical range for the method extends to 800 ppb. Method Log: Prior to January 2006 samples, total nitrogen was determined on a Technicon segmented flow autoanalyzer. From 2006 to present, total nitrogen is determined by an Astoria-Pacific Astoria II segmented flow autoanalyzer. pH We sample at the deepest part of the lake using a peristaltic pump and tubing, monthly during open water and approximately every five weeks during ice cover. We collect two types of pH samples at each sampling depth: one in 20ml vials with cone cap inserts to exclude all air from the vial, and one in 125ml bottles to be air equilibrated before analysis. The depths for sample collection are based on thermal stratification: top and bottom of the epilimnion, mid thermocline, and top, middle,and bottom of the hypolimnion. During mixis we sample at the surface, mid water column, and bottom. We analyze for pH the same day that samples are collected, keeping them cold and dark until just before analysis. Samples are warmed to room temperature in a dark container, and the air equilibrated samples are bubbled with outside air for at least 15 minutes prior to measurement. We measure pH using a Radiometer combination pH electrode and Orion 4Star pH meter. Protocol Log: 1981-1988 -- used a PHM84 Research pH meter. 1986 -- began analyzing air equilibrated pH. 1988 - July 2010 -- used an Orion model 720 pH meter.</p>
Short Name
NTLGW02
Version Number
23

North Temperate Lakes LTER: Chemical Limnology of Primary Study Lakes: Nutrients, pH and Carbon 1981 - current

Abstract
Parameters characterizing the nutrient chemistry of the eleven primary lakes (Allequash, Big Muskellunge, Crystal, Sparkling, and Trout lakes, unnamed lakes 27-02 [Crystal Bog] and 12-15 [Trout Bog], Mendota, Monona, Wingra, and Fish) are measured at multiple depths throughout the year. These parameters include total nitrogen, total dissolved nitrogen, nitrite+nitrate-N, ammonium-N, total phosphorus, total dissolved phosphorus, dissolved reactive phosphorus (only in the southern lakes and not in Wingra and Fish after 2003), bicarbonate-reactive filtered and unfiltered silica (both discontinued in 2003), dissolved reactive silica, pH, air equilibrated pH (discontinued in 2014 in the northern lakes and in 2020 in the southern lakes), total alkalinity, total inorganic carbon, dissolved inorganic carbon, total organic carbon, dissolved organic carbon, and total particulate matter (only in the northern lakes in this data set; total particulate matter in southern lakes starting in 2000 is available in a separate dataset). Sampling Frequency: Northern lakes- monthly during ice-free season -- every 5 weeks during ice-covered season. Southern lakes- Southern lakes samples are collected every 2-4 weeks during the summer stratified period, at least monthly during the fall, and typically only once during the winter, depending on ice conditions. Number of sites: 11
Note that years 2020 & 2021 are not complete but we are publishing the data that we have. The dataset will be updated as new data is received.
Dataset ID
1
Date Range
-
DOI
10.6073/pasta/cc6f0e4d317d29200234c7243471472a
Maintenance
ongoing
Metadata Provider
Methods
Inorganic and organic carbon: Samples for inorganic and organic carbon are collected together with a peristaltic pump and tubing and in-line filtered, if necessary, (through a 0.40 micron polycarbonate filter) into glass, 24 ml vials (that are compatible with the carbon analyzer autosampler), and capped with septa, leaving no head space. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 2-3 weeks. The detection limit for inorganic carbon is 0.15 ppm, and the analytical range for the method is 60 ppm. The detection limit for organic carbon is 0.30 ppm and the analytical range for the method is 30 ppm. Method Log: Prior to May 2006 samples, inorganic carbon was analyzed by phosphoric acid addition on an OI Model 700 Carbon Analyzer. From May 2006 to present, inorganic carbon is still analyzed by phosphoric acid addition, but on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer. Method Log: Prior to May 2006 samples, organic carbon was analyzed by heated persulfate digestion on an OI Model 700 Carbon Analyzer. From May 2006 to present, Organic carbon is analyzed by combustion, on a Shimadzu TOC-V-csh Total Organic Carbon Analyzer. Dissolved reactive silica Samples for silica are collected with a peristaltic pump and tubing and in-line filtered (through a 45 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 ml of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. Dissolved reactive silica is determined by the Heteropoly Blue Method and the absorption is measured at 820 nm. The detection limit for silica is 6 ppb and the analytical range is 15000 ppb. Method Log These determinations were performed manually using a Bausch and Lomb Spectrophotometer from the beginning of the project until April 1984. From 1984 through 2005, dissolved reactive silica was determined on a Technicon Auto Analyzer II. From January 2006 to present, samples are run on an Astoria-Pacific Astoria II Autoanalyzer. total and dissolved nitrogen and phosphorus Samples for total and dissolved nitrogen and phosphorus analysis are collected together with a peristaltic pump and tubing and in-line filtered, when necessary, (through a 45 micron polycarbonate filter) into 120 ml LDPE bottles and acidified to a 1percent HCl matrix by adding 1 mL of ultra pure concentrated HCl to 100 mls of sample. For every sample acidification event, three acid blanks are created by adding the same acid used on the samples to 100 mls of ultra pure water supplied from the lab. Once acidified, the samples are stable at room temperature until analysis, which should occur within one year. Until acidification, the samples should be refrigerated at 4 degrees Celsius. The samples must first be prepared for analysis by adding an NaOH–Persulfate digestion reagent and heated for an hour at 120 degrees C and 18-20 psi in an autoclave. The samples are analyzed for total nitrogen and total phosphorus simultaneously by automated colorimetric spectrophotometry, using a segmented flow autoanalyzer. Total nitrogen is determined by utilizing the automated cadmium reduction method, as described in Standard Methods, where the absorption is monitored at 520 nm. The detection limit for total and dissolved nitrogen is approximately 21 ppb and the analytical range for the method extends to 2500 ppb. The detection limit for total phosphorus is approximately 3 ppb and the analytical range for the method extends to 800 ppb. Method Log: Prior to January 2006 samples, total nitrogen was determined on a Technicon segmented flow autoanalyzer. From 2006 to present, total nitrogen is determined by an Astoria-Pacific Astoria II segmented flow autoanalyzer.
Short Name
NTLCH01
Version Number
59

North Temperate Lakes LTER: Chemical Limnology of Primary Study Lakes: Major Ions 1981 - current

Abstract
Parameters characterizing the major ions of the eleven primary lakes (Allequash, Big Muskellunge, Crystal, Sparkling, Trout, bog lakes 27-02 [Crystal Bog], and 12-15 [Trout Bog], Mendota, Monona, Wingra and Fish) are measured at one station in the deepest part of each lake at the top and bottom of the epilimnion, mid-thermocline, and top, middle, and bottom of the hypolimnion. These parameters include chloride, sulfate, calcium, magnesium, sodium, potassium, iron, manganese, and specific conductance (northern lakes only). Sampling Frequency: quarterly (winter, spring and fall mixis, and summer stratified periods) Number of sites: 11
Core Areas
Dataset ID
2
Date Range
-
Maintenance
ongoing
Metadata Provider
Methods
Chloride, Sulfate Samples for chloride and sulfate are collected together with a peristaltic pump and tubing and in-line filtered (through a 0.40 micron polycarbonate filter) into new, 20 ml HDPE plastic containers with conical caps. The samples are stored refrigerated at 4 degrees Celsius until analysis, which should occur within 6 months. The samples are analyzed for chloride (and sulfate) simultaneously by Ion Chromatography, using a hydroxide eluent. The detection limit for chloride is approximately 0.01 ppm and the analytical range for the method extends to 100 ppm. The detection limit for sulfate is approximately 0.01 ppm and the analytical range for the method extends to 60 ppm. Method Log: Prior to January 1998 samples, chloride was determined on a Dionex DX10 Ion Chromatograph, using a chemical fiber suppressor. From 1998 to 2011, chloride was determined by a Dionex model DX500, using an electro-chemical suppressor. From January 2011 until present, chloride is determined by a Dionex model ICS 2100 using an electro-chemical suppressor.
Short Name
NTLCH02
Version Number
37
Subscribe to water chemistry