US Long-Term Ecological Research Network

LTREB Biological Limnology at Lake Myvatn 2012-current

Abstract
These data are part of a long-term monitoring program in the central part of Myvatn that represents the dominant habitat, with benthos consisting of diatomaceous ooze. The program was designed to characterize import benthis and pelagic variables across years as midge populations varied in abundance. Starting in 2012 samples were taken at roughly weekly inervals during June, July, and August, which corresponds to the summer generation of the dominant midge,<em>Tanytarsus gracilentus</em>.
Creator
Dataset ID
296
Date Range
-
Maintenance
Ongoing
Metadata Provider
Methods
Benthic Chlorophyll Field sampling (5 samples) (2012, 2013)1. Take 5 cores from the lake2. Cut the first 0.75 cm (1 chip) of the core with the extruder and place in deli container. Label with date and core number.3. Place deli containers into opaque container (cooler) and return to lab. This is the same sample that is used for the organic matter analysis.In 2014, the method for sampling benthic chlorophyll changed. The calculation of chlorophyll was changed to reflect the different area sampled. Below is the pertinent section from the methods protocols. Processing after the collection of the sample was not changed.Take sediment samples from the 5 cores collected for sediment characteristics. Take 4 syringes of sediment with 10mL syringe (15.96mm diameter). Take 4-5cm of sediment. Then, remove bottom 2cm and place top 2cm in the film canister.Filtering1. Measure volume of material in deli container with 60mL syringe and record.2. Homogenize and take 1mL sample with micropipette. The tip on the micropipette should be cut to avoid clogging with diatoms. Place the 1mL sample in a labeled film canister. Freeze sample at negative 20 degrees Celsius unless starting methanol extraction immediately.3. Add 20mL methanol. This methanol can be kept cool in the fridge, although then you will need a second bottle of methanol for the fluorometer. Shake for 5 sec.4. After 6-18 hours, shake container for 5 sec.Fluorometer1. Allow the film canisters to sit at room temperature for approximately 15 min to avoid excessive condensation on the glass tubes. Shake tubes for 5 sec after removing from fridge but then be careful to let them settle before removing sample.2. Record the sample information for all of the film canisters on the data sheet.3. Add 4mL of sample to a 13x100mL glass tube.4. Insert the sample into the fluorometer and record the reading in the Fluor Before Acid column. The sample reading should be close to one of the secondary solid standards (42ug/L or 230ug/L), if not, dilute the sample to within 25 per cent of the secondary solid standards (30-54ug/L or 180-280ug/L). It is a good idea to quickly check 2mL of a sample that is suspected to be too high to get an idea if other samples may need to be diluted. If possible, read the samples undiluted.5. If a sample needs to be diluted, use a 1000 microLiter pipette and add 2mL of methanol to a tube followed by 2mL of undiluted sample. Gently invert the tube twice and clean the bottom with a paper towel before inserting it into the fluorometer. If the sample is still outside of the ranges above, combine 1 mL of undiluted sample with 3 mL of methanol. Be sure to record the dilution information on the data sheet.6. Acidify the sample by adding 120microLiters of 0.1 N HCl (30microLiters for every one mL of sample). Then gently invert the sample and wait 90 seconds (we used 60 seconds in 2012, the protocol said 90) before putting the sample into the fluorometer and recording the reading in the Fluor After Acid column. Be sure to have acid in each tube for exactly the same amount of time. This means doing one tube at a time or spacing them 30-60 seconds apart.7. Double check the results and redo samples, which have suspicious numbers. Make sure that the after-acidification values make sense when compared to the before acidification value (the before acid/after acid ratio should be approximately the same for all samples).Clean up1. Methanol can be disposed of down the drain as long as at least 50 times as much water is flushed.2. Rinse the film canisters and lids well with tap water and scrub them out with a bottle brush making sure to remove any remaining filter paper. Give a final rinse with distilled water. Pelagic Chlorophyll Field sampling (5 samples)1. Take 2 samples at each of three depths, 1, 2, and 3m with Arni&rsquo;s zooplankton trap. For the 1m sample, drop the trap to the top of the chain. Each trap contains about 2.5L of water when full. 2. Empty into bucket by opening the bottom flap with your hand.3. Take bucket to lab.Filtering1. Filter 1L water from integrated water sample (or until the filter is clogged) through the 47 mm GF/F filter. The pressure used during filtering should be low ( less than 5 mm Hg) to prevent cell breakage. Filtering and handling of filters should be performed under dimmed lighting.2. Remove the filter with forceps, fold it in half (pigment side in), and put it in the film canister. Take care to not touch the pigments with the forceps.3. Add 20mL methanol. This methanol can be kept cool in the fridge, although then you will need a second bottle of methanol for the fluorometer. Shake for 5 sec. and place in fridge.4. After 6-18 hours, shake container for 5 sec.5. Analyze sample in fluorometer after 24 hours.Fluorometer1. Allow the film canisters to sit at room temperature for approximately 15 min to avoid excessive condensation on the glass tubes. Shake tubes for 5 sec after removing from fridge but then be careful to let them settle before removing sample.2. Record the sample information for all of the film canisters on the data sheet.3. Add 4mL of sample to a 13x100mL glass tube.4. Insert the sample into the fluorometer and record the reading in the Fluor Before Acid column. The sample reading should be close to one of the secondary solid standards (42ug/L or 230ug/L), if not, dilute the sample to within 25 percent of the secondary solid standards (30-54ug/L or 180-280ug/L). It is a good idea to quickly check 2mL of a sample that is suspected to be too high to get an idea if other samples may need to be diluted. If possible, read the samples undiluted.5. If a sample needs to be diluted, use a 1000uL pipette and add 2mL of methanol to a tube followed by 2mL of undiluted sample. Gently invert the tube twice and clean the bottom with a paper towel before inserting it into the fluorometer. If the sample is still outside of the ranges above, combine 1 mL of undiluted sample with 3 mL of methanol. Be sure to record the dilution information on the data sheet.6. Acidify the sample by adding 120 microLiters of 0.1 N HCl (30 microLiters for every one mL of sample). Then gently invert the sample and wait 90 seconds (we used 60 seconds in 2012, the protocol said 90) before putting the sample into the fluorometer and recording the reading in the Fluor After Acid column. Be sure to have acid in each tube for exactly the same amount of time. This means doing one tube at a time or spacing them 30-60 seconds apart.7. Double check the results and redo samples, which have suspicious numbers. Make sure that the after-acidification values make sense when compared to the before acidification value (the before acid/after acid ratio should be approximately the same for all samples).Clean up1. Methanol can be disposed of down the drain as long as at least 50 times as much water is flushed.2. Rinse the film canisters and lids well with tap water and scrub them out with a bottle brush making sure to remove any remaining filter paper. Give a final rinse with distilled water. Pelagic Zooplankton Counts Field samplingUse Arni&rsquo;s zooplankton trap (modified Schindler) to take 2 samples at each of 1, 2, and 3m (6 total). For the 1m sample, drop the trap to the top of the chain. Each trap contains about 2.5L of water when full. Integrate samples in bucket and bring back to lab for further processing.Sample preparation in lab1. Sieve integrated plankton tows through 63&micro;m mesh and record volume of full sample2. Collect in Nalgene bottles and make total volume to 50mL3. Add 8 drops of lugol to fix zooplankton.4. Label bottle with sample date, benthic or pelagic zooplankton, and total volume sieved. Samples can be stored in the fridge until time of countingCounting1. Remove sample from fridge2. Sieve sample with 63 micro meter mesh over lab sink to remove Lugol&rsquo;s solution (which vaporizes under light)3. Suspend sample in water in sieve and flush from the back with squirt bottle into counting tray4. Homogenize sample with forceps or plastic pipette with tip cut off5. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted as well.6. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridgeSubsamplingIf homogenized original sample contains more than 500 individuals in the first line of counting tray, you may subsample under the following procedure.1. Return original sample to Nalgene bottle and add water to 50mL2. Homogenize sample by swirling Nalgene bottle3. Collect 10mL of zooplankton sample with Hensen-Stempel pipette4. Empty contents of Hensen-Stempel pipette into large Bogorov tray5. Homogenize sample in tray with forceps or plastic pipette with tip cut off6. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too! 7. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridge Benthic Microcrustacean Counts Field samplingLeave benthic zooplankton sampler for 24h. Benthic sampler consists of 10 inverted jars with funnel traps in metal grid with 4 feet. Set up on bench using feet (on side) to get a uniform height of the collection jars (lip of jar = 5cm above frame). Upon collection, pull sampler STRAIGHT up, remove jars, homogenize in bucket and bring back to lab. Move the boat slightly to avoid placing sampler directly over cored sediment.Sample preparation in lab1. Sieve integrated samples through 63 micrometer mesh and record volume of full sample2. Collect in Nalgene bottles and make total volume to 50mL3. Add 8 drops of lugol to fix zooplankton.4. Label bottle with sample date, benthic or pelagic zooplankton, and total volume sieved. Samples can be stored in the fridge until time of countingCounting1. Remove sample from fridge2. Sieve sample with 63 micrometer mesh over lab sink to remove Lugol&rsquo;s solution (which vaporizes under light)3. Suspend sample in water in sieve and flush from the back with squirt bottle into counting tray4. Homogenize sample with forceps or plastic pipette with tip cut off5. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too!6. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridgeSubsamplingIf homogenized original sample contains more than 500 individuals in the first line of counting tray, you may subsample under the following procedure.1. Return original sample to Nalgene bottle and add water to 50mL2. Homogenize sample by swirling Nalgene bottle3. Collect 10mL of zooplankton sample with Hensen-Stempel pipette4. Empty contents of Hensen-Stempel pipette into large Bogorov tray5. Homogenize sample in tray with forceps or plastic pipette with tip cut off6. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too! 7. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridge Chironomid Counts (2012, 2013) For first instar chironomids in top 1.5cm of sediment only (5 samples)1. Use sink hose to sieve sediment through 63 micrometer mesh. You may use moderate pressure to break up tubes.2. Back flush sieve contents into small deli container.3. Return label to deli cup (sticking to underside of lid works well).For later instar chironomids in the section 1.5-11.5cm (5 samples)4. Sieve with 125 micrometer mesh in the field.5. Sieve through 125micrometer mesh again in lab to reduce volume of sample.6. Transfer sample to deli container or pitfall counting tray.For all chironomid samples7. Under dissecting scope, pick through sieved contents for midge larvae. You may have to open tubes with forceps in order to check for larvae inside.8. Remove larvae with forceps while counting, and place into a vial containing 70 percent ethanol. Larvae will eventually be sorted into taxonomic groups (see key). You may sort them into taxonomic groups as you pick the larvae, or you can identify the larvae while measuring head capsules if chironomid densities are low (under 50 individuals per taxanomic group).9. For a random sample of up to 50 individuals of each taxonomic group, measure head capsule, see Chironomid size (head capsule width).10. Archive samples from each sampling date together in a single 20mL glass vial with screw cap in 70 percent ethanol and label with sample contents , Chir, sample date, lake ID, station ID, and number of cores. Chironomid Cound (2014) In 2014, the method for sampling chironomid larvae changed starting with the sample on 2014-06-27; the variable &quot;top_bottom&quot; is coded as a 2. In contrast to previous measurements, the top and bottom core samples were combined and then subsampled. Below is the pertinent section of the protocols.Chironomid samples should be counted within 24 hours of collection. This ensures that larvae are as active and easily identified as possible, and also prevents predatory chironomids from consuming other larvae. Samples should be refrigerated upon returning from the field.<strong>For first instar chironomids in top 1.5cm of sediment only (5 samples)</strong>1. Use sink hose to sieve sediment through 63&micro;m mesh. You may use moderate pressure to break up tubes.2. Back flush sieve contents using a water bottle into small deli container.3. Return label to deli cup (sticking to underside of lid works well).<strong>For larger instar chironomids in the section 1.5-11.5cm (5 samples)</strong>4. Sieve with 125&micro;m mesh in the field.5. Sieve through 125&micro;m mesh again in lab to reduce volume of sample and break up tubes.6. Transfer sample to deli container with the appropriate label.<strong>Subsample if necessary</strong>If necessary, subsample with the following protocol.a. Combine top and bottom samples from each core (1-5) in midge sample splitter.b. Homogenize sample thoroughly, collect one half in deli container, and label container with core number and &ldquo;1/2&rdquo;c. If necessary, split the half that remains in the sampler into quarters, and collect each in deli containers labeled with core number, &ldquo;1/4&rdquo;, and replicate 1 or 2d. Store all deli containers in fridge until counted, and save until all counting is complete&quot; Chironomid Size (head capsule width) 1. Obtain picked samples preserved in ethanol and empty onto petri dish.2. Sort larvae by family groups, arranging in same orientation for easy measurment.3. Set magnification to 20, diopter, x 50 times4. Take measurments for up to 50 or more individuals of each taxa. Round to nearest optical micrometer unit.5. Fill out data sheet for number of larvae in each taxa, Chironomid measurements for each taxa, date of sample, station sample was taken from, which core the sample came from, who picked the core, and your name as the measurer.6. Enter data into shared sheetSee &quot;Chironomid Counts&quot; for changes in sampling chironomid larvae in 2014.
Version Number
17

Trout Lake USGS Water, Energy, and Biogeochemical Budgets (WEBB) Stream Data 1975-current

Abstract
This data was collected by the United States Geological Survey (USGS) for the Water, Energy, and Biogeochemical Budget Project. The data set is primarily composed of water chemistry variables, and was collected from four USGS stream gauge stations in the Northern Highland Lake District of Wisconsin, near Trout Lake. The four USGS stream gauge stations are Allequash Creek at County Highway M (USGS-05357215), Stevenson Creek at County Highway M (USGS-05357225), North Creek at Trout Lake (USGS-05357230), and the Trout River at Trout Lake (USGS-05357245), all near Boulder Junction, Wisconsin. The project has collected stream water chemistry data for a maximum of 36 different chemical parameters,. and three different physical stream parameters: temperature, discharge, and gauge height. All water chemistry samples are collected as grab samples and sent to the USGS National Water Quality Lab in Denver, Colorado. There is historic data for Stevenson Creek from 1975-1977, and then beginning again in 1991. The Trout Lake WEBB project began during the summer of 1991 and sampling of all four sites continues to date.
Creator
Dataset ID
276
Date Range
-
Maintenance
Completed.
Metadata Provider
Methods
DL is used to represent “detection limit” where known.NOTE (1): Each method listed below corresponds with a USGS Parameter Code, which is listed after the variable name. NOTE (2): If the NEMI method # is known, it is also specified at the end of each method description.NOTE (3): Some of the variables are calculated using algorithms within QWDATA. If this is the case see Appendix D of the NWIS User’s Manual for additional information. However, appendix D does not list the algorithm used by the USGS. If a variable is calculated with an algorithm the term: algor, will be listed after the variable name.anc: 99431, Alkalinity is determined in the field by using the gran function plot methods, see TWRI Book 9 Chapter A6.1. anc_1: 90410 and 00410, Alkalinity is determined by titrating the water sample with a standard solution of a strong acid. The end point of the titration is selected as pH 4.5. See USGS TWRI 5-A1/1989, p 57, NEMI method #: I-2030-89.2. c13_c12_ratio: 82081, Exact method unknown. The following method is suspected: Automated dual inlet isotope ratio analysis with sample preparation by precipitation with ammoniacal strontium chloride solution, filtration, purification, acidified of strontium carbonate; sample size is greater than 25 micromoles of carbon; one-sigma uncertainty is approximately ± 0.1 ‰. See USGS Determination of the delta13 C of Dissolved Inorganic Carbon in Water, RSIL Lab Code 1710. Chapter 18 of Section C, Stable Isotope-Ratio Methods Book 10, Methods of the Reston Stable Isotope Laboratory.3. ca, mg, mn, na, and sr all share the same method. The USGS parameter codes are listed first, then the method description with NEMI method #, and finally DL’s:ca- 00915, mg- 00925, mn- 01056, na- 00930, sr- 01080All metals are determined simultaneously on a single sample by a direct reading emission spectrometric method using an inductively coupled argon plasma as an excitation source. Samples are pumped into a crossflow pneumatic nebulizer, and introduced into the plasma through a spray chamber and torch assembly. Each analysis is determined on the basis of the average of three replicate integrations, each of which is background corrected by a spectrum shifting technique except for lithium (670.7 nm) and sodium (589.0 nm). A series of five mixed-element standards and a blank are used for calibration. Method requires an autosampler and emission spectrometry system. See USGS OF 93-125, p 101, NEMI Method #: I-1472-87.DL’s: ca- .02 mg/l, mg-.01 mg/l, mn-1.0 ug/l, na- .2 mg/l, sr- .5 ug/l4. cl, f, and so4 all share the same method. The USGS parameter codes are listed first, then the method description with NEMI method #, and finally DL’s:cl- 00940, f-00950, so4-00945All three anions (chloride, flouride, and sulfate) are separated chromatographically following a single sample injection on an ion exchange column. Ions are separated on the basis of their affinity for the exchange sites of the resin. The separated anions in their acid form are measured using an electrical conductivity cell. Anions are identified on the basis of their retention times compared with known standards. 19 The peak height or area is measured and compared with an analytical curve generated from known standards to quantify the results. See USGS OF 93-125, p 19, NEMI method #: I-2057.DL’s: cl-.2 mg/l, f-.1 mg/l, so4-.2 mg/lco2: 00405, algor, see NWIS User's Manual, QW System, Appendix D, Page 285.co3: 00445, algor.color: 00080, The color of the water is compared to that of the colored glass disks that have been calibrated to correspond to the platinum-cobalt scale of Hazen (1892), See USGS TWRI 5-A1 or1989, P.191, NEMI Method #: I-1250. DL: 1 Pt-Co colorconductance_field: 00094 and 00095, specific conductance is determined in the field using a standard YSI multimeter, See USGS TWRI 9, 6.3.3.A, P. 13, NEMI method #: NFM 6.3.3.A-SW.conductance_lab: 90095, specific conductance is determined by using a wheat and one bridge in which a variable resistance is adjusted so that it is equal to the resistance of the unknown solution between platinized electrodes of a standardized conductivity cell, sample at 25 degrees celcius, See USGS TWRI 5-A1/1989, p 461, NEMI method #: I-1780-85.dic: 00691, This test method can be used to make independent measurements of IC and TC and can also determine TOC as the difference of TC and IC. The basic steps of the procedure are as follows:(1) Removal of IC, if desired, by vacuum degassing;(2) Conversion of remaining inorganic carbon to CO<sub>2</sub> by action of acid in both channels and oxidation of total carbon to CO<sub>2</sub> by action of ultraviolet (UV) radiation in the TC channel. For further information, See ASTM Standards, NEMI method #: D6317. DL: n/adkn: 00623 and 99894, Organic nitrogen compounds are reduced to the ammonium ion by digestion with sulfuric acid in the presence of mercuric sulfate, which acts as a catalyst, and potassium sulfate. The ammonium ion produced by this digestion, as well as the ammonium ion originally present, is determined by reaction with sodium salicylate, sodium nitroprusside, and sodium hypochlorite in an alkaline medium. The resulting color is directly proportional to the concentration of ammonia present, see USGS TWRI 5-A1/1989, p 327, NEMI method #: 351.2. DL: .10 mg/Ldo: 0300, Dissolved oxygen is measured in the field with a standard YSI multimeter, NEMI Method #: NFM 6.2.1-Lum. DL: 1 mg/L.doc: 00681, The sample is acidified, purged to remove carbonates and bicarbonates, and the organic carbon is oxidized to carbon dioxide with persulfate, in the presence of an ultraviolet light. The carbon dioxide is measured by nondispersive infrared spectrometry, see USGS OF 92-480, NEMI Method #: O-1122-92. DL: .10 mg/L.don: 00607, algor, see NWIS User's Manual, QW System, Appendix D, page 291.dp: 00666 and 99893, All forms of phosphorus, including organic phosphorus, are converted to orthophosphate ions using reagents and reaction parameters identical to those used in the block digester procedure for determination of organic nitrogen plus ammonia, that is, sulfuric acid, potassium sulfate, and mercury (II) at a temperature of 370 deg, see USGS OF Report 92-146, or USGS TWRI 5-A1/1979, p 453, NEMI method #: I-2610-91. DL= .012 mg/L.fe: 01046, Iron is determined by atomic absorption spectrometry by direct aspiration of the sample solution into an air-acetylene flame, see USGS TWRI 5-A1/1985, NEMI method #: I-1381. DL= 10µg/L.h_ion: 00191, algor.h20_hardness: 00900, algor.h20_hardness_2: 00902, algor.hco3: 00440, algor.k: 00935, Potassium is determined by atomic absorption spectrometry by direct aspiration of the sample solution into an air-acetylene flame , see USGS TWRI 5-A1/1989, p 393, NEMI method #: I-1630-85. DL= .01 mg/L.n_mixed: 00600, algor.n_mixed_1: 00602, algor.n_mixed_2: 71887, algor.nh3_nh4: 00608, Ammonia reacts with salicylate and hypochlorite ions in the presence of ferricyanide ions to form the salicylic acid analog of indophenol blue (Reardon and others, 1966; Patton and Crouch, 1977; Harfmann and Crouch, 1989). The resulting color is directly proportional to the concentration of ammonia present, See USGS OF 93-125, p 125/1986 (mg/l as N), NEMI Method #: I-2525. DL= .01 mg/L.nh3_nh4_1: 71846, algor.nh3_nh4_2: 00610, same method as 00608, except see USGS TWRI 5-A1/1989, p 321. DL = .01 mg/L.nh3_nh4_3: 71845, algor.no2: 00613, Nitrite ion reacts with sulfanilamide under acidic conditions to form a diazo compound which then couples with N-1-naphthylethylenediamine dihydrochloride to form a red compound, the absorbance of which is measured colorimetrically, see USGS TWRI 5-A1/1989, p 343, NEMI method #: I-2540-90. DL= .01 mg/L.no2_2: 71856, algor.no3: 00618, Nitrate is determined sequentially with six other anions by ion-exchange chromatography, see USGS TWRI 5-A1/1989, P. 339, NEMI method #: I-2057. DL= .05 mg/L.no3_2: 71851, algor.no32: 00630, An acidified sodium chloride extraction procedure is used to extract nitrate and nitrite from samples of bottom material for this determination(Jackson, 1958). Nitrate is reduced to nitrite by cadmium metal. Imidazole is used to buffer the analytical stream. The sample stream then is treated with sulfanilamide to yield a diazo compound, which couples with N-lnaphthylethylenediamine dihydrochloride to form an azo dye, the absorbance of which is measured colorimetrically. Procedure is used to extract nitrate and nitrite from bottom material for this determination (Jackson, 1958), see USGS TWRI 5-A1/1989, p 351. DL= .1 mg/Lno32_2: 00631, same as description for no32, except see USGS OF 93-125, p 157. DL= .1 mg/L.o18_o16_ratio: 82085, Sample preparation by equilibration with carbon dioxide and automated analysis; sample size is 0.1 to 2.0 milliliters of water. For 2-mL samples, the 2-sigma uncertainties of oxygen isotopic measurement results are 0.2 ‰. This means that if the same sample were resubmitted for isotopic analysis, the newly measured value would lie within the uncertainty bounds 95 percent of the time. Water is extracted from soils and plants by distillation with toluene; recommended sample size is 1-5 ml water per analysis, see USGS Determination of the Determination of the delta (18 O or 16O) of Water, RSIL Lab Code 489.o2sat: Dissolved oxygen is measured in the field with a standard YSI multimeter, which also measures % oxygen saturation, NEMI Method #: NFM 6.2.1-Lum.ph_field: 00400, pH determined in situ, using a standard YSI multimeter, see USGS Techniques of Water-Resources Investigations, book 9, Chaps. A1-A9, Chap. A6.4 "pH," NEMI method # NFM 6.4.3.A-SW. DL= .01 pH.ph_lab: 00403, involves use of laboratory pH meter, see USGS TWRI 5-A1/1989, p 363, NEMI method #: I-1586.po4: 00660, algor, see NWIS User's Manual, QW System, Appendix D, Page 286.po4_2: 00671, see USGS TWRI 5-A1/1989, NEMI method #: I-2602. DL= .01 mg/L.s: 63719, cannot determine exact method used. USGS method code: 7704-34-9 is typically used to measure sulfur as a percentage, with an DL =.01 µg/L. It is known that the units for sulfur measurements in this data set are micrograms per liter.sar: 00931, algor, see NWIS User's Manual, QW System, Appendix D, Page 288.si: 00955, Silica reacts with molybdate reagent in acid media to form a yellow silicomolybdate complex. This complex is reduced by ascorbic acid to form the molybdate blue color. The silicomolybdate complex may form either as an alpha or beta polymorph or as a mixture of both. Because the two polymorphic forms have absorbance maxima at different wavelengths, the pH of the mixture is kept below 2.5, a condition that favors formation of the beta polymorph (Govett, 1961; Mullen and Riley, 1955; Strickland, 1952), see USGS TWRI 5-A1/1989, p 417, NEMI method #: I-2700-85. DL= .10 mg/L.spc: 00932, algor, see NWIS User's Manual, QW System, Appendix D, Page 289.tds: 70300 and 70301, A well-mixed sample is filtered through a standard glass fiber filter. The filtrate is evaporated and dried to constant weight at 180 deg C, see " Filterable Residue by Drying Oven," NEMI method #: 160.1, DL= 10 mg/l. Note: despite DL values occur in the data set that are less than 10 mg/l.tds_1: 70301, algor, see NWIS User's Manual, QW System, Appendix D, Page 289.tds_2: 70303, algor, see NWIS User's Manual, QW System, Appendix D, Page 290.tkn: 00625 and 99892, Block digester procedure for determination of organic nitrogen plus ammonia, that is, sulfuric acid, potassium sulfate, and Mercury (II) at a temperature of 370°C. See the USGS Open File Report 92-146 for further details. DL: .10 mg/L.toc: 00680, The sample is acidified, purged to remove carbonates and bicarbonates, and the organic carbon is oxidized to carbon dioxide with persulfate, in the presence of an ultraviolet light. The carbon dioxide is measured by nondispersive infrared spectrometry, see USGS TWRI 5-A3/1987, p 15, NEMI Method #: O-1122-92. DL=.10 mg/L.ton: 00605, algor, See NWIS User's Manual, QW System, Appendix D, page 286.tp: 00665 and 99891, This method may be used to analyze most water, wastewater, brines, and water-suspended sediment containing from 0.01 to 1.0 mg/L of phosphorus. Samples containing greater concentrations need to be diluted, see USGS TWRI 5-A1/1989, p 367, NEMI method #: I-4607. tp_2: 71886, algor.tpc: 00694, The basic steps of this test method are:1) Conversion of remaining IC to CO2 by action of acid, 2) Removal of IC, if desired, by vacuum degassing, 3) Split of flow into two streams to provide for separate IC and TC measurements, 4) Oxidation of TC to CO2 by action of acid-persulfate aided by ultraviolet (UV) radiation in the TC channel, 5) Detection of CO2 by passing each liquid stream over membranes that allow the specific passage of CO2 to high-purity water where change in conductivity is measured, and 6) Conversion of the conductivity detector signal to a display of carbon concentration in parts per million (ppm = mg/L) or parts per billion (ppb = ug/L). The IC channel reading is subtracted from the TC channel reading to give a TOC reading, see ASTM Standards, NEMI Method #: D5997. DL= .06 µg/L.tpn: 49570, A weighed amount of dried particulate (from water) or sediment is combusted at a high temperature using an elemental analyzer. The combustion products are passed over a copper reduction tube to covert nitrogen oxides to molecular nitrogen. Carbon dioxide, nitrogen, and water vapor are mixed at a known volume, temperature, and pressure. The concentrations of nitrogen and carbon are determined using a series of thermal conductivity detectors/traps, measuring in turn by difference hydrogen (as water vapor), carbon (as carbon dioxide), and nitrogen (as molecular nitrogen). Procedures also are provided to differentiate between organic and inorganic carbon, if desired, see USEPA Method 440, NEMI method #: 440. DL= .01 mg/L.
Short Name
TL-USGS-WEBB Data
Version Number
15

South: Fish Crew Sampling

NIGHT SEINING
 
Night seining is conducted to achieve relative abundances of small fish species such as minnows, darters, sculpin, and young gamefish species on a yearly basis. Seining is most effective on small fish at night, due to reduced net avoidance, and is one of the most effective methods of catching small fish species.
 
A.     The seine used is 12.2 m long by 1.2 m deep, consisting of two 5.5 x 1.2 m wings surrounding a 1.2 x 1.2 x 1.2 m central bag.

South: Fish Crew Equipment List

Common Gear for all Fish Sampling:
 
  • Scale Envelopes
  • Spring scales (2 of each, with one set in separate dry place): 10, 30, 50, 100, 500, 1000 mg, 5 kg, 12 kg
  • Measuring Boards
  • Dip Nets
  • iPaq               
  • Bins for storing fish
  • aerator(s)
  • GPS
  • Site Book
  • Collector’s Permit
  • Tool box
Forceps
Needle nose pliers
Wire cutter

South: Macrophyte Sampling

Macrophyte Sampling Schedule

1.       Macrophytes are sampled on Lakes Mendota, Monona, Wingra, and Fish Lake. Keep the sampling dates as consistent to past years as much as possible (see previous years’ field sheet dates). Working around the routine LTER sampling, schedule the macrophyte sampling well in advance in order to sign out a vehicle and boat when necessary.
 

Macrophyte Sampling Preparation

South: Total Particulate Matter

 Total particulate material (TPM) is an estimate of the mass of particles in the water column.  In this method particles are defined as material not passing through a polycarbonate track-etched (PCTE) filter having a 0.4mm pore size.
 
 
SUPPLIES NEEDED
  • PCTE filters with pore size of 0.4 µm (Fisher Catalog No. 09-732-37)
  • petri dishes for filter storage (Fisher Catalog No.

South: Field Sampling Routine

A. Nutrient Sampling: Refer to the Field Sheet to see which bottles need to be sampled at which depths and the 'Southern Lakes LTER Bottle Codes’ for preservation, filtering, and coding information.
 
1.     Purge the lines: Whenever sampling from a new depth, the peristaltic pump tubing must be purged of the water from the previous depth. After reaching the proper sampling depth, use a graduated cylinder to measure the volume of water purged before beginning the sampling. Purge at least 1200 mL of water for each 20 meters of tu
Subscribe to sampling