US Long-Term Ecological Research Network

Cascade Project at North Temperate Lakes LTER High Frequency Sonde Data from Food Web Resilience Experiment 2008 - 2011

Abstract
High-frequency sonde data collected from the surface waters of two lakes in Upper Peninsula of Michigan during the summers of 2008-2011. The food web of Peter Lake was slowly transformed by gradual additions of Largemouth bass (Micropterus salmoides) while Paul Lake was an unmanipulated reference. Sonde data were used to calculate resilience indicators to evaluate the stability of the food web and to calculate ecosystem metabolism.
Dataset ID
360
Date Range
-
Methods
Data were collected at 5 minute intervals using in-situ automated sensors (sondes). All measurements and samples were collected from a stationary raft over the deepest part of the lake.
Sondes were suspended from floats with probes at a depth of 0.75m below the surface. Sonde sensors were cleaned daily in the field and calibrated monthly following manufacturer guidelines. Peter and Paul lakes were each monitored with two YSI multiparameter sondes (model 6600 V2-4) fitted with optical DO (model 6150), pH (model 6561), optical Chl-a (model 6025), and conductivity-temperature (model 6560) probes. Sensor measurements were made at 0.75 m every 5 min and were calibrated weekly. PAR was measured and the UNDERC meteorology station maintained by the University of Notre Dame or by the North Temperate Lakes Weather Station at Woodruff Airport.
Outliers were replaced by NA. Occasional gaps in the record due to instrument cleaning are NA.
Version Number
1

LTREB Biological Limnology at Lake Myvatn 2012-current

Abstract
These data are part of a long-term monitoring program in the central part of Myvatn that represents the dominant habitat, with benthos consisting of diatomaceous ooze. The program was designed to characterize import benthis and pelagic variables across years as midge populations varied in abundance. Starting in 2012 samples were taken at roughly weekly inervals during June, July, and August, which corresponds to the summer generation of the dominant midge,<em>Tanytarsus gracilentus</em>.
Creator
Dataset ID
296
Date Range
-
Maintenance
Ongoing
Metadata Provider
Methods
Benthic Chlorophyll Field sampling (5 samples) (2012, 2013)1. Take 5 cores from the lake2. Cut the first 0.75 cm (1 chip) of the core with the extruder and place in deli container. Label with date and core number.3. Place deli containers into opaque container (cooler) and return to lab. This is the same sample that is used for the organic matter analysis.In 2014, the method for sampling benthic chlorophyll changed. The calculation of chlorophyll was changed to reflect the different area sampled. Below is the pertinent section from the methods protocols. Processing after the collection of the sample was not changed.Take sediment samples from the 5 cores collected for sediment characteristics. Take 4 syringes of sediment with 10mL syringe (15.96mm diameter). Take 4-5cm of sediment. Then, remove bottom 2cm and place top 2cm in the film canister.Filtering1. Measure volume of material in deli container with 60mL syringe and record.2. Homogenize and take 1mL sample with micropipette. The tip on the micropipette should be cut to avoid clogging with diatoms. Place the 1mL sample in a labeled film canister. Freeze sample at negative 20 degrees Celsius unless starting methanol extraction immediately.3. Add 20mL methanol. This methanol can be kept cool in the fridge, although then you will need a second bottle of methanol for the fluorometer. Shake for 5 sec.4. After 6-18 hours, shake container for 5 sec.Fluorometer1. Allow the film canisters to sit at room temperature for approximately 15 min to avoid excessive condensation on the glass tubes. Shake tubes for 5 sec after removing from fridge but then be careful to let them settle before removing sample.2. Record the sample information for all of the film canisters on the data sheet.3. Add 4mL of sample to a 13x100mL glass tube.4. Insert the sample into the fluorometer and record the reading in the Fluor Before Acid column. The sample reading should be close to one of the secondary solid standards (42ug/L or 230ug/L), if not, dilute the sample to within 25 per cent of the secondary solid standards (30-54ug/L or 180-280ug/L). It is a good idea to quickly check 2mL of a sample that is suspected to be too high to get an idea if other samples may need to be diluted. If possible, read the samples undiluted.5. If a sample needs to be diluted, use a 1000 microLiter pipette and add 2mL of methanol to a tube followed by 2mL of undiluted sample. Gently invert the tube twice and clean the bottom with a paper towel before inserting it into the fluorometer. If the sample is still outside of the ranges above, combine 1 mL of undiluted sample with 3 mL of methanol. Be sure to record the dilution information on the data sheet.6. Acidify the sample by adding 120microLiters of 0.1 N HCl (30microLiters for every one mL of sample). Then gently invert the sample and wait 90 seconds (we used 60 seconds in 2012, the protocol said 90) before putting the sample into the fluorometer and recording the reading in the Fluor After Acid column. Be sure to have acid in each tube for exactly the same amount of time. This means doing one tube at a time or spacing them 30-60 seconds apart.7. Double check the results and redo samples, which have suspicious numbers. Make sure that the after-acidification values make sense when compared to the before acidification value (the before acid/after acid ratio should be approximately the same for all samples).Clean up1. Methanol can be disposed of down the drain as long as at least 50 times as much water is flushed.2. Rinse the film canisters and lids well with tap water and scrub them out with a bottle brush making sure to remove any remaining filter paper. Give a final rinse with distilled water. Pelagic Chlorophyll Field sampling (5 samples)1. Take 2 samples at each of three depths, 1, 2, and 3m with Arni&rsquo;s zooplankton trap. For the 1m sample, drop the trap to the top of the chain. Each trap contains about 2.5L of water when full. 2. Empty into bucket by opening the bottom flap with your hand.3. Take bucket to lab.Filtering1. Filter 1L water from integrated water sample (or until the filter is clogged) through the 47 mm GF/F filter. The pressure used during filtering should be low ( less than 5 mm Hg) to prevent cell breakage. Filtering and handling of filters should be performed under dimmed lighting.2. Remove the filter with forceps, fold it in half (pigment side in), and put it in the film canister. Take care to not touch the pigments with the forceps.3. Add 20mL methanol. This methanol can be kept cool in the fridge, although then you will need a second bottle of methanol for the fluorometer. Shake for 5 sec. and place in fridge.4. After 6-18 hours, shake container for 5 sec.5. Analyze sample in fluorometer after 24 hours.Fluorometer1. Allow the film canisters to sit at room temperature for approximately 15 min to avoid excessive condensation on the glass tubes. Shake tubes for 5 sec after removing from fridge but then be careful to let them settle before removing sample.2. Record the sample information for all of the film canisters on the data sheet.3. Add 4mL of sample to a 13x100mL glass tube.4. Insert the sample into the fluorometer and record the reading in the Fluor Before Acid column. The sample reading should be close to one of the secondary solid standards (42ug/L or 230ug/L), if not, dilute the sample to within 25 percent of the secondary solid standards (30-54ug/L or 180-280ug/L). It is a good idea to quickly check 2mL of a sample that is suspected to be too high to get an idea if other samples may need to be diluted. If possible, read the samples undiluted.5. If a sample needs to be diluted, use a 1000uL pipette and add 2mL of methanol to a tube followed by 2mL of undiluted sample. Gently invert the tube twice and clean the bottom with a paper towel before inserting it into the fluorometer. If the sample is still outside of the ranges above, combine 1 mL of undiluted sample with 3 mL of methanol. Be sure to record the dilution information on the data sheet.6. Acidify the sample by adding 120 microLiters of 0.1 N HCl (30 microLiters for every one mL of sample). Then gently invert the sample and wait 90 seconds (we used 60 seconds in 2012, the protocol said 90) before putting the sample into the fluorometer and recording the reading in the Fluor After Acid column. Be sure to have acid in each tube for exactly the same amount of time. This means doing one tube at a time or spacing them 30-60 seconds apart.7. Double check the results and redo samples, which have suspicious numbers. Make sure that the after-acidification values make sense when compared to the before acidification value (the before acid/after acid ratio should be approximately the same for all samples).Clean up1. Methanol can be disposed of down the drain as long as at least 50 times as much water is flushed.2. Rinse the film canisters and lids well with tap water and scrub them out with a bottle brush making sure to remove any remaining filter paper. Give a final rinse with distilled water. Pelagic Zooplankton Counts Field samplingUse Arni&rsquo;s zooplankton trap (modified Schindler) to take 2 samples at each of 1, 2, and 3m (6 total). For the 1m sample, drop the trap to the top of the chain. Each trap contains about 2.5L of water when full. Integrate samples in bucket and bring back to lab for further processing.Sample preparation in lab1. Sieve integrated plankton tows through 63&micro;m mesh and record volume of full sample2. Collect in Nalgene bottles and make total volume to 50mL3. Add 8 drops of lugol to fix zooplankton.4. Label bottle with sample date, benthic or pelagic zooplankton, and total volume sieved. Samples can be stored in the fridge until time of countingCounting1. Remove sample from fridge2. Sieve sample with 63 micro meter mesh over lab sink to remove Lugol&rsquo;s solution (which vaporizes under light)3. Suspend sample in water in sieve and flush from the back with squirt bottle into counting tray4. Homogenize sample with forceps or plastic pipette with tip cut off5. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted as well.6. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridgeSubsamplingIf homogenized original sample contains more than 500 individuals in the first line of counting tray, you may subsample under the following procedure.1. Return original sample to Nalgene bottle and add water to 50mL2. Homogenize sample by swirling Nalgene bottle3. Collect 10mL of zooplankton sample with Hensen-Stempel pipette4. Empty contents of Hensen-Stempel pipette into large Bogorov tray5. Homogenize sample in tray with forceps or plastic pipette with tip cut off6. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too! 7. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridge Benthic Microcrustacean Counts Field samplingLeave benthic zooplankton sampler for 24h. Benthic sampler consists of 10 inverted jars with funnel traps in metal grid with 4 feet. Set up on bench using feet (on side) to get a uniform height of the collection jars (lip of jar = 5cm above frame). Upon collection, pull sampler STRAIGHT up, remove jars, homogenize in bucket and bring back to lab. Move the boat slightly to avoid placing sampler directly over cored sediment.Sample preparation in lab1. Sieve integrated samples through 63 micrometer mesh and record volume of full sample2. Collect in Nalgene bottles and make total volume to 50mL3. Add 8 drops of lugol to fix zooplankton.4. Label bottle with sample date, benthic or pelagic zooplankton, and total volume sieved. Samples can be stored in the fridge until time of countingCounting1. Remove sample from fridge2. Sieve sample with 63 micrometer mesh over lab sink to remove Lugol&rsquo;s solution (which vaporizes under light)3. Suspend sample in water in sieve and flush from the back with squirt bottle into counting tray4. Homogenize sample with forceps or plastic pipette with tip cut off5. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too!6. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridgeSubsamplingIf homogenized original sample contains more than 500 individuals in the first line of counting tray, you may subsample under the following procedure.1. Return original sample to Nalgene bottle and add water to 50mL2. Homogenize sample by swirling Nalgene bottle3. Collect 10mL of zooplankton sample with Hensen-Stempel pipette4. Empty contents of Hensen-Stempel pipette into large Bogorov tray5. Homogenize sample in tray with forceps or plastic pipette with tip cut off6. Identify (see zooplankton identification guide) using backlit microscope and count with multiple-tally counter. i. Set magnification so that you can see both top and bottom walls of the tray. ii. Change focus depth to check for floating zooplankton that must be counted, too! 7. Pipette sample back into Nalgene bottle, add water to 50mL, add 8 drops Lugol&rsquo;s solution, and return to fridge Chironomid Counts (2012, 2013) For first instar chironomids in top 1.5cm of sediment only (5 samples)1. Use sink hose to sieve sediment through 63 micrometer mesh. You may use moderate pressure to break up tubes.2. Back flush sieve contents into small deli container.3. Return label to deli cup (sticking to underside of lid works well).For later instar chironomids in the section 1.5-11.5cm (5 samples)4. Sieve with 125 micrometer mesh in the field.5. Sieve through 125micrometer mesh again in lab to reduce volume of sample.6. Transfer sample to deli container or pitfall counting tray.For all chironomid samples7. Under dissecting scope, pick through sieved contents for midge larvae. You may have to open tubes with forceps in order to check for larvae inside.8. Remove larvae with forceps while counting, and place into a vial containing 70 percent ethanol. Larvae will eventually be sorted into taxonomic groups (see key). You may sort them into taxonomic groups as you pick the larvae, or you can identify the larvae while measuring head capsules if chironomid densities are low (under 50 individuals per taxanomic group).9. For a random sample of up to 50 individuals of each taxonomic group, measure head capsule, see Chironomid size (head capsule width).10. Archive samples from each sampling date together in a single 20mL glass vial with screw cap in 70 percent ethanol and label with sample contents , Chir, sample date, lake ID, station ID, and number of cores. Chironomid Cound (2014) In 2014, the method for sampling chironomid larvae changed starting with the sample on 2014-06-27; the variable &quot;top_bottom&quot; is coded as a 2. In contrast to previous measurements, the top and bottom core samples were combined and then subsampled. Below is the pertinent section of the protocols.Chironomid samples should be counted within 24 hours of collection. This ensures that larvae are as active and easily identified as possible, and also prevents predatory chironomids from consuming other larvae. Samples should be refrigerated upon returning from the field.<strong>For first instar chironomids in top 1.5cm of sediment only (5 samples)</strong>1. Use sink hose to sieve sediment through 63&micro;m mesh. You may use moderate pressure to break up tubes.2. Back flush sieve contents using a water bottle into small deli container.3. Return label to deli cup (sticking to underside of lid works well).<strong>For larger instar chironomids in the section 1.5-11.5cm (5 samples)</strong>4. Sieve with 125&micro;m mesh in the field.5. Sieve through 125&micro;m mesh again in lab to reduce volume of sample and break up tubes.6. Transfer sample to deli container with the appropriate label.<strong>Subsample if necessary</strong>If necessary, subsample with the following protocol.a. Combine top and bottom samples from each core (1-5) in midge sample splitter.b. Homogenize sample thoroughly, collect one half in deli container, and label container with core number and &ldquo;1/2&rdquo;c. If necessary, split the half that remains in the sampler into quarters, and collect each in deli containers labeled with core number, &ldquo;1/4&rdquo;, and replicate 1 or 2d. Store all deli containers in fridge until counted, and save until all counting is complete&quot; Chironomid Size (head capsule width) 1. Obtain picked samples preserved in ethanol and empty onto petri dish.2. Sort larvae by family groups, arranging in same orientation for easy measurment.3. Set magnification to 20, diopter, x 50 times4. Take measurments for up to 50 or more individuals of each taxa. Round to nearest optical micrometer unit.5. Fill out data sheet for number of larvae in each taxa, Chironomid measurements for each taxa, date of sample, station sample was taken from, which core the sample came from, who picked the core, and your name as the measurer.6. Enter data into shared sheetSee &quot;Chironomid Counts&quot; for changes in sampling chironomid larvae in 2014.
Version Number
17

Light Extinction

Light (PAR) extinction coefficient is calculated by linearly regressing ln (FRLIGHT (z)) on depth z where the intercept is not constrained. FRLIGHT(z) = LIGHT(z) / DECK(z) where LIGHT(z) is light measured at depth z and DECK(z) is light measured on deck (above water) at the same time.

Lake Metabolism

Study sites
We sampled surface waters of 31 lakes in the Northern Highland Lake district of Wisconsin and the Upper Peninsula of Michigan during July and August of 2000 (Table 1). The lakes were chosen to span wide and orthogonal ranges in DOC and TP concentrations and for their close proximity to the Trout Lake Station in Vilas county, Wisconsin. The order in which the lakes were sampled was randomized.

North Temperate Lakes LTER: Physical Limnology of Primary Study Lakes 1981 - current

Abstract
Parameters characterizing the physical limnology of the eleven primary lakes (Allequash, Big Muskellunge, Crystal, Sparkling, Trout, bog lakes 27-02 [Crystal Bog] and 12-15 [Trout Bog], Mendota, Monona, Wingra and Fish) are measured at one station in the deepest part of each lake at 0.25-m to 1-m depth intervals depending on the lake. Measured parameters in the data set include water temperature, vertical penetration of photosynthetically active radiation (PAR; not measured on lakes Mendota, Monona, Wingra, and Fish), dissolved oxygen, as well as the derived parameter percent oxygen saturation. Sampling Frequency: fortnightly during ice-free season - every 6 weeks during ice-covered season for the northern lakes. The southern lakes are similar except that sampling occurs monthly during the fall and typically only once during the winter (depending on ice conditions). Number of sites: 11
Core Areas
Dataset ID
29
Date Range
-
Maintenance
ongoing
Metadata Provider
Methods
Light (PAR) extinction coefficient is calculated by linearly regressing ln (FRLIGHT (z)) on depth z where the intercept is not constrained. FRLIGHT(z) = LIGHT(z) or DECK(z) where LIGHT(z) is light measured at depth z and DECK(z) is light measured on deck (above water) at the same time. For open water light profiles, the surface light measurement (depth z = 0) is excluded from the regression. For winter light profiles taken beneath the ice, the first light data are taken at the bottom of the ice cover and are included in the regression. The depth of uppermost light value is equal to the depth of the ice adjusted by the water level in the sample hole, i.e., the depth below the surface of the water. The water level can be at, above or below the surface of the ice. If the water level was not recorded, it is assumed to be 0.0 and the calculated light extinction coefficient is flagged. If ice thickness was not recorded, a light extinction coefficient is not calculated. For light data collected prior to March, 2007, light values less than 3.0 (micromolesPerMeterSquaredPerSec) are excluded. For light data collected starting in March 2007, light values less than 1.0 (micromolesPerMeterSquaredPerSec) are excluded. Except for bog lakes before August 1989, a light extinction coefficient is not calculated if there are less than three FRLIGHT values to be regressed. For bog lakes before August 1989, a light extinction coefficient is calculated if there are least two FRLIGHT values to be regressed. In these cases, the light extinction coefficient is flagged as non-standard. FRLIGHT values should be monotonically decreasing with depth. For light profiles where this is not true, a light extinction coefficient is not calculated. For samples for which light data at depth are present, but the corresponding deck light are missing, a light extinction coefficient is calculated by regressing ln (LIGHT (z)) on depth z. Note that if actual deck light had remained constant during the recording of the light profile, the resulting light extinction coefficient is the same as from regressing ln(FRLIGHT(z)). In these cases, the light extinction coefficient is flagged as non-standard. Oxygen and Temperature: We sample at the deepest part of the lake, taking a temperature and oxygen profile at meter intervals from the surface to within 1 meter of the bottom using a YSI Pro-ODO temporDO meter. We sample biweekly during open water and approximately every five weeks during ice cover. Protocol Log: Prior to 2011, we used a YSI Model 58 temporDO meter.
Short Name
NTLPH01
Version Number
27
Subscribe to photosynthetically active radiation